Table 3-4 Power supply cable and Earth Leakage Breaker(Recommended) Termin Earth leakage breaker *1 al Recomm Model Power supply block ended Cable qty. x Sensitivity Rated voltage size*2 screw crimp of leak current current terminal diamet [A] [mA] er 4 cores x AWG10 3phase HRS100-A-2030 R5.5-5 (4 cores x 5.5mm2) 200VAC(50Hz) HRS100-W-20*including ground 3phase 4 cores x AWG8 HRS150-A-20200
To use the power from the device, the total load current must be 200 mA or less. 2:Refer to 3.3.6 Wiring of the contact output signal HRL Series 3.3 Installation 3-19 HRX-OM-X037 Chapter 3 Transport and Setting Up Table 3.3-4 Contact input/output communicatin /Analog output pin number PIN No.
MHC MHT MHY MHY Max. tightening torque (Nm) Model Applicable bolts MHW2-20D MHW2-25D MHW2-32D MHW2-40D MHW2-50D 1.4 2.5 4.1 10.6 24.5 M4 x 0.7 M5 x 0.8 M6 x 1 M8 x 1.25 M10 x 1.5 MHW MHW -X MRHQ MA D723
180 Angular Type Air Gripper MHY2/MHW2 Series 10, 16, 20, 25 MHZ MHF MHL MHR MHK MHS MHC MHT MHY MHY MHW MHW -X MRHQ MA D697 180 Angular Type Air Gripper MHY2/MHW2 Series Cam Type Rack & Pinion Type MHY2 Series/Cam Type Light and compact size in small bore sizes Over length L (mm) Gripping moment Weight (g) Bore size (mm) Model (Nm) L MHY2-10D 10 0.16 70 71 MHY2-16D 16 150 0.54 84 MHY2-20D
48 VAC, DC: 40 mA 100 VAC, DC: 20 mA Non plug-in type Note 1) Combining valve VFR41 (single) and release valve spacer makes it possible to use this as an air release valve.
48 VAC/DC: 40 mA 100 VAC/DC: 20 mA VS4 Max. switch capacity Note 1) Voltage: 24 VDC to 100 VAC Inner voltage drop: 4 V Note 2) Combination of a valve VFS41 (single) and a release valve spacer can be used as an air release valve.
MA B Auto switch mounting heights D-A9V D-F9V D-F9WV (mm) Bore size (mm) D-A9V D-F9V D-F9WV D-F9BAL MA MA MA 20 25 25 27 25 27 27.5 29.5 A Approx.
MA B D-A9V D-F9V D-F9WV Auto switch mounting heights (mm) Bore size (mm) D-A9V D-F9V D-F9WV D-F9BAL SMC D-A90V SMC D-A90V MA MA MA 20 25 25.5 27.5 25.5 27.5 28 30 A Approx.
or less Switch Output NPN or PNP open collector OUT1: General-purposeOUT2: Valve control Maximum load current 80 mA Max. applied voltage DC26.4 V Residual voltage Max. 2 V (at 80 mA load current) Response time 2.5 ms or less (response times available for anti-chattering function: 20, 100, 500, 1000 or 2000 ms) Short circuit protection Provided Repeatability 0.2%F.S.1 digit Hysteresis Hysteresis
Current consumption [Power supply voltage] 1.5 V Power supply voltage for sensor 40 mA maximum (100 mA maximum for the total power supply current when 4 sensors are input.)
3 rotations 200 degrees 200 degrees 25 mA or less (When 24 VDC is ON) 16 mA 0.5 MPa 5 to 20 mA Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 0.2 MPa When using ejector system, instantaneous pressure up to 0.5 MPa will not damage the switch.
.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com I CX D D-X 202 x 4J E MB Data MC KA MA C NA K NB S + Stroke H B ZZ + Stroke The allowable angle difference of E to B should be limited to 1.5.
Output mode Hysteresis, Window comparator, Error output, Output OFF Switch operation Normal output, Reversed output Maximum load current 80 mA Switch output (SIO mode) Maximum applied voltage 30 V (NPN output) Internal voltage drop (Residual voltage) 1.5 V or less (at load current of 80 mA) Delay time*1 1.5 ms or less, variable from 0 to 60 s/0.01 s increments Hysteresis Hysteresis mode Variable
48 VAC, DC: 40 mA 100 VAC, DC: 20 mA For detailed specifications on the IS10 series, refer to the IS10 series section of the SMC website: http://www.smcworld.com Separate spacers are required for modular unit.
GD Breaker Capacity and Sensitivity Current Sensitivity current IDFB4E to 37E IDFB55E, 75E Model Breaker capacity 10 A 30 mA Maximum operating pressure: 240 psi (1.6 MPa) 10 A 30 mA Replacement Parts Configuration Replacement part no.
or less (at no load) NPN or PNP open collector output: 1 output 80 mA 30 V (With NPN output) 1 V or less (With load current of 80 mA) 1 s (0.25, 0.5, 2, 3 selections) Yes 1% F.S.
2.0% F.S. or less (0 to 50C, based on 25C)NPN open collector Max. load current: 80 mA; Max. applied voltage: 30 V; Internal voltage drop: 1 V or less (with load current of 80 mA)PNP open collector Max. load current: 80 mA; Internal voltage drop: 1.5 V or less (with load current of 80 mA)NPN or PNP open collector Flow rate per pulse: 100 l/pulse, 10.0 ft3/pulseON time per pulse
2.0% F.S. or less (0 to 50C, based on 25C)NPN open collector Max. load current: 80 mA; Max. applied voltage: 30 V; Internal voltage drop: 1 V or less (with load current of 80 mA)PNP open collector Max. load current: 80 mA; Internal voltage drop: 1.5 V or less (with load current of 80 mA)NPN or PNP open collector Flow rate per pulse: 100 l/pulse, 10.0 ft3/pulseON time per pulse
2.0% F.S. or less (0 to 50C, based on 25C)NPN open collector Max. load current: 80 mA; Max. applied voltage: 30 V; Internal voltage drop: 1 V or less (with load current of 80 mA)PNP open collector Max. load current: 80 mA; Internal voltage drop: 1.5 V or less (with load current of 80 mA)NPN or PNP open collector Flow rate per pulse: 100 l/pulse, 10.0 ft3/pulseON time per pulse
Table 11-1 EX245-DX1 (W x L x H) mm 54 x 120 x 61 280g , PBT 24 V DC 1.6 V 50 mA 8 x M125 A code 2 / US1 30V /1 0.5A /1 2 A 1 16 PNP ON 11 to 30 V OFF -3 to 5 V 1.5mA ON Typ. 4.5 mA 24VDC 71 No.EX##-OMY0006CN 11.3. /SI IP65M12 M12,5 , Table 11-2 EX245-DX1 (TOP View) 1 24 V 2 2 DI ( n+1) 3 5 1 3 0 V (US1) 4 DI (n) 4 5 FE/ 11.4.