NIL IDF 100 F 30 4 W C 5 G Size K Size Air compressor size Note) 100kW 125kW 150kW 100 125 150 P R Note) The value is referential. Confirm the capability of the compressor used.
In general, 80 to 100 mesh (150 to 180 m) filters are recommended. When transferring a coagulable liquid, take measures to prevent it from coagulating in the pump. Flammable fluid cannot be used with the process pump with built-in solenoid valve (PB1011A). Do not use in an environment where flammable fumes are present or where flammable liquid may get stuck to the product.
Pressure characteristics*4 2.5% F.S. (0.1 to 1.0 MPa, 0.5 MPa standard) Pressure Electrical Power supply voltage 24 VDC 10% Current consumption 150 mA or less Protection Polarity protection Display accuracy 3.0% F.S. Analog output accuracy 3.0% F.S. Accuracy Repeatability Switch output/Display: 1.0% F.S. Analog output: 1.0% F.S. Temperature characteristics 5.0% F.S.
screen) Line name Expanded flow range Compact, Space saving Wide range of flow measurement with one product Compared with the current PF2A, Flow ratio 78 % reduction Weight 74% reduction 100:1 Mounting space 1100 g a 240 g Compared with PFMC7202-06 and PF2A703H-10 Rated flow ratio is 10 : 1 for current PF2A. 2000 L type 55 Applicable flow range [L/min] PFMC7202 New 1 2 5 10 20 25 50 100 150
Additional weight 0.23/50 stroke Stroke 100 stroke 0.46 + 100 / 50 X 0.23 = 0.92kg Standard Stroke (mm) Size Standard stroke Max. stroke(mm) 25, 32, 40 50, 63 5, 10, 15, 20, 25, 30, 35, 40, 45, 50 75, 100, 125, 150, 175, 200, 250, 300 300 Contact SMC for any intermediate strokes that are not indicated above, as they will be produced upon receipt of order.
CJ216 16 15, 30, 45, 60, 75, 100, 125, 150, 175, 200 Air cushion is not available for 21-/22-.
(not including sensor accuracy), Response time: 150 ms or less Accuracy (to display value) (25C) 1.0% F.S. or less 1.5% F.S. or less 2.0% F.S. or less 0.5% F.S.
(Not including sensor accuracy), Response time: 150 ms or less Accuracy (To display value) (25C) 1.0% F .S. or less 1.5% F .S. or less 2.0% F .S. or less PF2 0.5% F .S.
180 210.5 226 250 135 140 155 134 146 162.5 20 24 24 VNC5-32F VNC6-40F VNC7-50F 100 105 120 36 42 54 12 12 14 310.5 326 350 278 293.5 317.5 VX Port size: 65F, 80F Flange connection VN VQ Applicable flange 65 80 Model H F E D C B A 1 4 1 4 405.5 441.5 65 80 140 150 204 235 175 185 305.5 341.5 210 240 VNC81 -65F VNC91 -80F 4.2-25 VNC Construction N.C.
I ':"1 6 65 274 1 7 7 1 7 7 6 52 55 -r5 loo . 6 . 202 202 6 8 65 320 227 227 6 47 75 litzs . 70 345 252 252 6 47 150 6 8 370 277 2 7 7 r 1 65 T-slot A dimensions T-slot B dimensions $unies tX$ tilo To 0[dEl' tlect|'ic Acl||at0 AC Servo Motor 100vAc TS45O1N -rslsotl I Nole 1) l Applicable Applicable TarnaFwa Sek I 2OOVAC TS45O1N AppLicable L Applicable 3 -.'
x-cov-450-50 xRAY-450-150 Weld SDatter Covers x-cov-450-r 50 To Mount 6.5mm Prox.
, 200 201 to 350 Minimum stroke for mounting auto switches 25 301 to 400 32 301 to 450 Number of auto switches Model 40 301 to 800 25, 50, 75, 100, 125, 150, 200, 250, 300 2 pcs. 1 pc. 50, 63 301 to 1200 D-G5BA 15mm 10mm 80 301 to 1400 Refer to page 15 for details. 100 301 to 1500 Note 1) All non-standard strokes are produced upon receipt of order.
200 50 100 150 200 Arm length [mm] Arm length [mm] The maximum clamping force when the arm length is 100 mm and the operating pressure is 44 psi [0.3 MPa]: With an arm length of 100 mm and an operating pressure of 44 psi [0.3 MPa], according to the graph, the maximum clamping force is 45 lbf [200 N].
Ambient and fluid temperature (C) Response time (ms) (1) (at the pressure of 0.5 MPa) 0 (No freezing) to 60 OFF AC 30 or less ON AC 30 or less DC 30 or less DC 40 or less Max. operating frequency (Hz) 3 Lubrication (2) Required (Equivalent to turbine oil Class1 ISO VG32) Manual override Yes (Non-locking) Mounting orientation Unrestricted 150/50 Impact/Vibration resistance (m/s2) (3) Note
Form w 1 Material e Buffer spec. r Buffer stroke t Vacuum inlet y Connection thread 10 55.5 32.5 23 20 93.5 42.5 51 30 103.5 52.5 40 139.5 62.5 77 50 149.5 72.5 10 13 21 D2 10 56 33 23 20 94 43 51 30 104 53 40 140 63 77 50 150 73 Construction p. 118 16 21.5 B5 04 06 N6 U6 Buffer Assembly p. 124 J: 2.5 K: 2 M10 x 1 A10 14 3 8 M5 x 0.8 10 57.5 34.5 23 20 95.5 44.5 51 30 105.5 54.5 40 141.5
AMH150-03 AMH250-03 AMH250-03 AMH350-04 AMH350-04 AMH450-06 AMH550-10 AMH550-10 AMH650-14 AMH850-20 AM850-20 AMH850-20 IDG20-03 IDG30-03 IDG50-03 IDG75-04 IDG100-04 IDF2D-1 IDF3DIDF4DIDF6DIDF8DIDF11CIDF15CIDF22C1-3 IDF37C1-3 IDF55C-3 IDF75D-3 IDF120D-3 IDF150D-3 IDF240D-3 IDF55C-3 AM850-20 AMD850-20 75 AMF1000-40 AMF900-30 AMF850-20 AMD850-20 AMD910-30 AMD910-40 AMD1010-40 IDF120D-3 110 150
Caution Be sure to read before handling.Refer to pages 14-21-3 to 4 for Safety Instructions and Common Precautions on the products mentioned in this catalog, pages 14-14-6 to 8 for Precautions on every series, and pages 14-20-62 to 64 for more detailed precautions on every series. 14-20-22 2 Micro Mist Separator Series AMD How to Order AMD150 to AMD850 AMD 250 03 J B Body size Option 1 4 150
P . 14-20-57 14-20-42 2 Odor Removal Filter Series AMF How to Order AMF150 to AMF850 AMF 250 03 R B Option R IN-OUT reversal direction Body size Bracket Accessory (Option) 150 Standard 1 8 250 Standard 1 4 350 Standard 3 8 450 Standard 1 2 550 Standard 3 4 650 850 B 1 4 B 3 8 04 B 1 2 06 B Nil Nil B Piping port (B dimension) 1 Standard 11 2 Standard 01 B 1 8 02 03 Thread type Nil Rc F G N
Applicable dryer Capacity Model Inlet voltage Outlet voltage A B C D E F Weight (kg) 200, 220 230, 240 VAC (50 Hz) 200 to 260 VAC (60 Hz) 100 VAC (50 Hz) 100 to 110 VAC (60 Hz) Single phase Single turn IDF-TR500-2 IDF1E-10 to 8E-10 IDU3E-10, 4E-10 500 VA 118 140 150 70 112 142 6 IDF-TR500-3, 4 C VOLUTAGE SELECTOR FUSE B OUT PUT IN PUT E D 4-F A Input cord 2 m Transformer part no.
C J G5-S 150 cm3/min or less 200 cm3/min or less 300 cm3/min or less Supply pressure 0.1 MPa Total allowable leakage 800 cm3/min or less 1000 cm3/min or less 1200 cm3/min or less Weight/Standard Type: MQQT Supply pressure 0.3 MPa CV 1500 cm3/min or less 2000 cm3/min or less 3000 cm3/min or less Supply pressure 0.5 MPa (g) Note 1) Use clean, dry air with no freezing.