SMC Corporation of America
Elite Part Number Search
Search Results "RZQF63-200-60-M9BL"

.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Passage symbol 1 2 3 100 VAC, 50/60 Hz 200 VAC, 50/60 Hz 110 VAC, 50/60 Hz 220 VAC, 50/60 Hz External pilot Nil VT N.C. (Normally closed) A N.O.

(Onty auto SWItch mounting bracket ISassembled at the lime of shipment) 2 Air Cylinder Series CS2 Specifications " Bore size (mm) 125 f 140 :1 1 60 . j Action Double actmg.

Current consumption 55 mA or less Protection Polarity protection Power supply voltage for sensor 1 Power supply voltage: 1.5 V Power supply current for sensor 2 Max.110 mA (However, the total power supply current of 4 input is 440 mA or less maximum) The total power supply current when used as an IO-Link device is 200 mA or less maximum Display accuracy (Linearity) 5.0%F.S.

to 230 200 to 240 200 to 230 200 to 240 200 to 240 200 to 240 200 to 240 200 to 240 A1 LECSA1-S A 10 A2 LECSA2-S * The length of the encoder, motor and lock B2 LECSB2T cables are the same.

Note 3) The symbol F in the dimensions indicates the position where the clamping force is generated defined by the product specifications. 82 WRF100 Dimensions WRF-S/S-type clamp arms (Without cover) WRF100-S200/S240 4 x M8 x 1.25 depth 12 108 60 2 x M12 x 1.75 through 25 25 80 0.015 0 2 x 8H7 ( ) 60 0.05 depth 12 (2 x 4 x M5 x 0.8 through) ( ) C B For limit switch mounting A 60 60 36 0.5

Circulating fluid set temperature 20 oC READY band width (upper/lower temperature range) 2 oC READY time 60 sec. Preparation is completed 60 seconds after the circulating fluid temperature reaches 18oC to 22oC.

Q [l/min(ANR)] = x D2 x W x (P2 + 0.101) x 60 x C 6 4 x 10 0. 101 VBAT10, VBAT20, VBAT38 Q [l/min(ANR)] = x 1002 x 200 x (0.8 + 0.101) x 60 x 1 = 841 4 x 106 0. 101 Select booster regulator size from flow characteristics table. Refer to page 14-9-3 for flow characteristics.

Cylinder ports should be NAMUR hole pattern. 100/200 V (50/60 Hz) 24 V 15 to +10% of rated voltage Class B or equivalent 5.0 VA/60 Hz, 5.6 VA/50 Hz 2.3 VA (1.5 W)/60 Hz, 3.4 VA (2.1 W) 9/50 Hz 1.8 W Grommet, Grommet terminal, Conduit terminal, DIN terminal Note 1) Use dry-air at low temperature. Note 2) Use turbine oil Class1 (ISO VG32), if lubricated.

80 Load N 20 40 60 80 Load N 20 40 60 100 Load N 12 12 12 L = 100mm L = 100mm L = 100mm MXP12-15 MXP12-25 MXP12-15 MXP12-25 0.05 0.04 0.08 MXP12-15 MXP12-25 MXP12-15 MXP12-25 MXP12-15 MXP12-25 MXP12-15 MXP12-25 Table displacement mm Table displacement mm Table displacement mm 0.04 0.03 0.06 0.03 0.04 0.02 0.02 0.01 0.02 0.01 0 50 100 150 Load N 0 50 100 150 Load N 0 50 100 150 Load N 200

Ball screw 0.03 80 3 100 Slide screw 0.05 200 2 Guide rod type Series LXP 200 3 Slide screw 0.05 100 4 Without motor brake 30 Ball screw 0.03 6 80 Ball bushing guide 100 Slide screw 0.05 Sanyo Denki Co., Ltd. 200 2 200 3 Slide screw 0.05 100 4 With motor brake 30 Ball screw 0.03 5 80 100 Slide screw 0.05 200 3 High rigidity slide table type Series LXS 200 4.5 Slide screw

No code 0 V3 L 1 H 2 4 No gauge port No pressure gauge Ports -30 in.Hg to 30 psig -30 in.Hg to 60 psig -30 in.Hg to 100 psig -30 in.Hg to 160 psig 0 to 200 psig 0 to 400 psig -0.1 to 0.2 MPa -0.1 to 0.4 MPa -0.1 to 0.7 MPa -0.1 to 1.1 MPa 0 to 1.4 MPa 0 to 3 MPa Code Ports 2 ports 3 ports 2PW 3PW Porting Configuration e w q w q 1) Other range available.

Table 3-1 Quality standard for fresh water (tap water) Item Standard value pH25oC 6.5 to 8.2 Electric conductivity (25oC) (S/cm) 100 to 800 Chloride ion (mgCl-/L) 200 or less 2-/L) 200 or less Sulphate ion (mgSO4 Acid consumption (pH4.8) (mgCaCO3/L) 100 or less Total hardness (mgCaCO3/L) 200 or less Calcium hardness (mgCaCO3/L) 150 or less Quality item Ion silica (mgSiO2/L) 50 or less Iron

Hz) 200 VAC (50/60 Hz) 110 to 120 VAC (50/60 Hz) 220 VAC (50/60 Hz) 24 VDC 12 VDC Other VY1 G Option D: Type D DIN terminal Nil G None PPA With pressure gauge AL How to Order Pilot Valve Assembly SF4 1 G 80 Y: Type Y DIN terminal Rated coil voltage 1 2 3 4 5 6 9 100 VAC (50/60 Hz) 200 VAC (50/60 Hz) 110 to 120 VAC (50/60 Hz) 220 VAC (50/60 Hz) 24 VDC 12 VDC Other Soft start-up valve Note

] 45 [200] 0 0 50 100 150 200 50 100 150 200 Arm length [mm] Arm length [mm] The maximum clamping force when the arm length is 100 mm and the operating pressure is 44 psi [0.3 MPa]: With an arm length of 100 mm and an operating pressure of 44 psi [0.3 MPa], according to the graph, the maximum clamping force is 45 lbf [200 N].

, 300 100, 125, 150, 175, 200, 250, 300, 400, 500 32 131 90 27 16 45 49.5 64 M14 X 1.5 14 4.5 14 40 177 136 27 16 52 57 71.5 M14 X 1.5 24 5 14 50 63 200, 300, 500 193 144 32 20 64 71 85.5 M18 X 1.5 22.5 7 18 200, 300, 500 194 145 32 20 77 84 98.5 M18 X 1.5 21 7 18 P T* X M N O Q Z L Bore size (mm) 32 40 50 63 Rc(PT) 1/8 57.5 41 34 5.5 M6 X 1 56 30 14 Rc(PT) 1/8 64.5 41 40 5.5 M6 X 1 62 30

to 700 200 to 700 200 to 1000 200 to1000 Eff. thread length 15.5 19.5 19.5 21 Bore (mm) 20 25 32 40 GB 47.5 49.5 51.5 51.5 GA 53.5 56.5 55 56 FZ 68 70 72 84 FW 38 44 50 60 FY 21 27 33 36 FX 51 53 55 66 FT 6 9 9 9 FD 7 7 7 9 F 16 16 19 21 E 14.5 18 18 20.5 D 10 12 12 16 B 32 36 44 53 A 18 22 22 24 H1 5 6 6 8 H2 8 8 9 11 REA REC Bore (mm) 20 25 32 40 S 192 193 195 201.5 Rc(PT)P 1/4 1/4 3/8

(mm) H I J K L C D E F U A B Z M N O P S Bore size (mm) 32 M10 x 1.5 60 4.5 14 8.5 73.5 12 16 45 20 31.5 65 14 34 5.5 9 depth 7 Rc1/8 58.5 40 M10 x 1.5 69 5 14 8.5 75.5 12 16 52 22 35 67 14 40 5.5 9 depth 7 Rc1/8 66 50 M12 x 1.75 86 7 18 11 87 15 20 64 25 41 76 19 50 6.6 11 depth 8 Rc1/4 80 63 M12 x 1.75 103 7 18 11 91 15 20 77 27 47.5 80 19 60 9 14 depth 10.5 Rc1/4 93 80 M16 x 2 132 6 22

Circulating fluid set temperature 20 oC READY band width (upper/lower temperature range) 2 oC READY time 60 sec. Preparation is completed 60 seconds after the circulating fluid temperature reaches 18oC to 22oC.

DC Specification Power consumption (W) Note 1) Temperature rise (C) Note 2) Size Apparent power (VA) Note 1) 2) Temperature rise (C) Note 3) Size Size 1 Size 2 2.5 3 60 60 Size 1 Size 2 2.5 3 60 60 Note 1) Power consumption, Apparent power: The value at ambient temperature of 20C and when the rated voltage is applied.

T NPTF Coil rated Electrical entry 3 8 G F 1 100 VAC, 50/60 Hz Grommet Nil T Conduit terminal Standard 4 1 2 Option 2 200 VAC, 50/60 Hz Port size Manual override P None Nil Option WTB Dripproof conduit terminal 3 110 VAC, 50/60 Hz 1 4 Rc 3 8 Rc 1 2 Rc 3 4 Rc 02 03 04 06 TZ Conduit terminal w/ surge voltage suppressor 4 220 VAC, 50/60 Hz How to Calculate the Flow Rate 5 24 VDC 9 Other TL