60 50 0 to 120 30 to 200 0 to 60 0 to 250 20 to 150 X X X X The above table covers only general characteristics of subject rubber materials.

, 250, 300, 350 M8 11 12 39.5 107 14 44 M10 13.5 16.5 46 115 16.5 49 WA Bore size (mm) ML S T U VA OA OB OL P PA PB PW Q R VB MM NN st 25 25 < st 100 100 < st 200 200 < st 300 300 < st 350 38 47 55 30 40 50 13 9 14 18 104 44 60 70 72 92 110 40 50 63 1/8 1/4 1/4 20 22 22 6.6 8.6 8.6 124 124 128 11 14 14 200 200 200 24 24 28 7.5 9 9 48 48 52 300 300 300 86 110 124 118 146 158 106 130 142

, 250, 300, 350 M8 11 12 39.5 107 14 44 M10 13.5 16.5 46 115 16.5 49 WA Bore size (mm) ML S T U VA OA OB OL P PA PB PW Q R VB MM NN st 25 25 < st 100 100 < st 200 200 < st 300 300 < st 350 38 47 55 30 40 50 13 9 14 18 104 44 60 70 72 92 110 40 50 63 1/8 1/4 1/4 20 22 22 6.6 8.6 8.6 124 124 128 11 14 14 200 200 200 24 24 28 7.5 9 9 48 48 52 300 300 300 86 110 124 118 146 158 106 130 142

Yes A90V Grommet IC circuit 100 V or less No Yes No Yes No 100 V, 200 V Relay PLC 200 V or less 12 V Connector 2-wire 24 V IC circuit 24 V or less PLC Terminal conduit 100 V, 200 V Yes Relay PLC DIN terminal Grommet Diagnostic indication (2-color indicator) 1 Water resistant type auto switches can be mounted on the above models, but in such case SMC cannot guarantee water resistance

100/200 100/200 100/200 100/200 100/200 100/200 100/200 100/200 100/200 ** Non-Standard Product, consult factory for lead time.

, 250, 300, 350 107 M8 39.5 14 44 11 12 115 M10 46 16.5 49 13.5 16.5 WA Bore size (mm) ML S T U VA OA OB OL P PA PB PW Q R VB MM NN st25 25200200 200 200 44 60 70 11 14 14 13 9 14 118 146 158 7.5 9 9 24 24 28 86 110 124 106 130 142 48 48 52 72 92 110 300 300 300 40 50 63 M8 x 1.25 M8 x

, 250, 300, 350 107 M8 39.5 14 44 11 12 115 M10 46 16.5 49 13.5 16.5 WA Bore size (mm) ML S T U VA OA OB OL P PA PB PW Q R VB MM NN st25 25200200 200 200 44 60 70 11 14 14 13 9 14 118 146 158 7.5 9 9 24 24 28 86 110 124 106 130 142 48 48 52 72 92 110 300 300 300 40 50 63 M8 x 1.25 M8 x

150 150 2759 200 200 2760 250 200 2760 325 325 2761 400 325 2761 Stroke (In Inches and Hundredths of Inches) Bore 150 200 250 325 400 Note: Quantity is one piece.

Standard Strokes Symbol Rubber bumper Bore size [mm] Standard stroke [mm] 12 (10 x 2) 16 (12 x 2) 10, 20, 30, 50, 100 20 (16 x 2) 25 (20 x 2) 20, 30, 50, 100, 150 32 (25 x 2) 40 (32 x 2) 50 (40 x 2) 63 (45 x 2) 80 (56 x 2) 100 (71 x 2) 25, 50, 100, 150, 200 Intermediate strokes are available as a special order. Refer to pages 10 and 11 for cylinders with auto switches.

Residence time of water at 20C is 5.5 x 10-6sec, whereas at 150C is 2.8 x 10-8 sec, or 200 times shorter.

Thermo-chiller Dual Channel Refrigerated Thermo-chiller for Lasers HRL Series How to Order HRL A 20 100 Power supply Cooling capacity CH1 CH2 100 9 kW 1 kW 200 19 kW 1 kW 300 26 kW 1 kW 20 3-phase 200 VAC (50 Hz) 3-phase 200 to 230 VAC (60 Hz) Pipe thread type Nil Rc F G (with Rc-G conversion tting) N NPT (with Rc-NPT conversion tting) Cooling method A Air-cooled refrigeration Specications

CM2 Bore size (in) Model no. 150 (1.5") 200 (2") 250 (2.5") 325 (3/25") 400 (4") D-A5, D-F5 D-A6, D-J5 NBT-150 NBT-200 NBT-200 NBT-325 NBT-325 CG1 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com MB MB1 Connector type M8-3 pin M8-4 pin M12-4 pin 1 2 1 4 CA2 2 1 Pin

CM2 Bore size (in) Model no. 150 (1.5") 200 (2") 250 (2.5") 325 (3/25") 400 (4") D-A5, D-F5 D-A6, D-J5 NBT-150 NBT-200 NBT-200 NBT-325 NBT-325 CG1 MB MB1 Connector type M8-3 pin M8-4 pin M12-4 pin 1 2 1 4 CA2 2 1 Pin arrangement CS1 3 4 4 3 3 C76 JIS C 4524, JIS C 4525, IEC 947-5-2, NECA 0402 300 m/s2 Applicable standards Impact resistant IP degress of protection Insulation resistance Withstand

Refer to pages starting with 181 for mounting. 95 95 100 8(4)-6.2 B () () (170) 110 20 95 95 A () () (150) A B 100 200 300 400 Stroke Model LG1H212NA-100-F LG1H212NA-200-F LG1H212NA-300-F LG1H212NA-400-F 60 160 260 80 180 280 Dimenstions inside ( ) are for a 100 mm stroke. Positioning Time Guide Positioning time Positioning time (sec.)

Made to Order (Refer to page 700 for details.) 699 AS-FG Series How to Order AS 200 1 F G 06 Lock nut option Nil J Hexagon lock nut Round lock nut Body size 100 200 205 300 400 M5 standard 1/8 standard 1/4 standard 3/8 standard 1/2 standard Made to Order (Refer to the below for details.) Applicable tubing O.D.

100 VAC, Hz 200 VAC, Hz 110 VAC, Hz 220 VAC, Hz 1 2 3 VQ Light/Surge voltage suppressor 50 60 50 60 Nil None 50 60 4 VKF With surge voltage suppressor (Grommet type is only available.)

L1 E1 R1 U1 A1 U1 R1 A MM NDH10 NZ MM NDH10 NX NX E1 L1 30 40 50 60 60 20 22 28 40 40 12 12.5 16.5 23.5 23.5 16 19 24 34 34 32 40 50, 63 80 100 32 40 50, 63 80 100 14 19 24 26 26 10 11 14 20 20 16 19 24 34 34 40 50 64 80 80 M10x1.25 M14 x 1.5 M18 x 1.5 M22 x 1.5 M26 x 1.5 M10 x 1.25 M14 x 1.5 M18 x 1.5 M22 x 1.5 M26 x 1.5 10 10 14 22 22 14 14 20 30 30 28 28 40 60 60 10 10 14 22 22 14 14 20

System setting items (example using compact Wireless Base EXW1-BMJA#) Parameter Set value Initial value I/O mapping Manual Manual Diagnostic allocation Advanced Advanced DA refresh time (sec) *1 0.1 / 0.2 / 0.5 / 1 / 2 / 5 / 10 / 30 / 60 s 1 s Output Action of Upper Communication Clear / Hold / Individual Clear Time of Wireless Communication 20 / 40 / 100/ 200 / 500 / 1,000 / 2,000 / 5,000

D-Y7GL Motor model Compatible driver model Power supply voltage (VAC) Motor output (W) + Brown lead wire MSD021P1E MSM021P1A Matsushita Electric Industrial Co., Ltd. 100/115 Main circuit of switch MSM022P1A 200 Output Black lead wire MSD023P1E 200/230 MR-C20A1 100/115 Mitsubishi Electric Corporation HC-PQ23 200 MR-C20A 200/230 SGDE-02BP 100/115 200 SGME-02BF12 Yaskawa Electric Corporation

VAC, 220 VAC, 230 VAC (50/60 Hz) Allowable voltage fluctuation 10% of rated voltage VX Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Coil insulation type Class H VX3 Power consumption (W) 50/60 Hz VCS2: 4.9/4.1, VCS3: 7.7/6.6, VCS4: 10.5/9.3 Inrush VCS2: 22/19,