NPN) IC A76H 5V Yes A72H A72 200V Grommet Reed switch Solid state switch A73H A73 100V 12V 5V 12V 100V or less Stroke (mm) No A80H A80 IC Relay, PLC 2 wire Refer to standard stroke on p.2.4-3. Refer to p.2.4-3 when using auto switch.
If supply pressure is other than P = 0.5 MPa, please figure out a max. stroke, using proportional calculation.
Note 1) ( ): Long stroke Note 2) Refer to p.1.6-11 for pivot bracket.
Refer to "Flow Characteristics" (p.4.6-2) and figure of "Max. air flow" (p.4.6-3).
l/min VCB 3 Cv = 0.35 3 4 Formula based on effective area (Smm) 1.0 Q = 0.8 S 10.2 P l/min VCB23 Cv = 0.33 VCB25 Cv = 0.65 Q: Flow rate (l/min) P:Pressure differential (P P) P: Upstream pressure (MPa) P: Downstream pressure (MPa) S: Effective area (mm) Cv: Cv factor VCB34 Cv = 0.54 VCB24 Cv = 0.51 0.1 0.001 0.01 0.1 1 10 Pressure differential P = (P P) MPa Note: 1l/min = 0.353SCFM
Type P. 9-15-23 Band, Rail, Tie-rod Mounting CNS CLS CLQ MLGP RLQ MLU P. 9-15-26 Solid State Switches ML1C DGeneral Purpose Type P. 9-15-27 Band, Rail, Tie-rod, Direct Mounting Normally Closed Type P. 9-15-39 Direct Mounting 2-color Indication Type P. 9-15-42 Band, Rail, Tie-rod Direct Mounting 2-color Indication Type with Diagnostic Output P. 9-15-50 Band, Rail, Tie-rod Mounting
Cushion valve G 2 x Rc P W V Port G E Width across flats KA TX D E B C H1 AL MM MB MA N 2 x 4 x J N TY B C Width across flats B1 A H K F TT ZZ + Stroke S + Stroke With rod boot d e 10.2 10.2 f h l [mm] Bore size [mm] A AL B B1 C D E F G H H1 J K KA MA MB MM N P S TT TX TY V W ZZ 32 22 19.5 46 17 32.5 12 30 13 13 47 6 M6 x 1 6 10 16 4 M10 x 1.25 27 1/8 84 17 48 49 4 6.5 135 40 30 27 52 22
Refer to "Flow Characteristics" (p.4.6-9) and figure of "Max. air flow" (p.4.6-8).
Real-time switch output ( ) Unit switching Hysteresis mode Display Real-time flow rate l/min Accumulated flow l ON YES OFF P-1 P-2 GPM gal (US) Real-time flow rate GPM = gal (US)/min "P" Window comparator mode H : Hysteresis Note ) Fixed SI unit (l/min, l, m3 or m3x10) will be set for the type without the unit switching function.
01 1 station Solenoid on same side of A and B port A port: Rc 1/8 B port: Rc 1/8 Nil P port: Rc 1/8 Thread type R port: Rc 1/8 20 Type S42 Solenoid on same side of A and B port 20 stations Type VK334 Nil F N T Rc S Port size Type VK3140 G P port: Rc 1/8 1 8 01 Rc C6 6 cassette NPT R port: Rc 1/8 NPTF B port: Rc 1/8 A port: Rc 1/8 Common SUP/Individual EXH Type 21: Body ported (A, B port
Real-time switch output Unit switching Hysteresis mode ON YES Accumulated flow l Display Real-time flow rate l/min OFF P-1 P-2 Real-time flow rate GPM gal (US) "P" Window comparator mode H : Hysteresis GPM = gal (US)/min H H Note) Fixed SI unit (l/min, l, m3 or m3x10) will be set for the type without the unit switching function.
FM P (BK) IDF15E1-10 PC CM ILS FM PTC OLR OLR ILS PTC PTC CM C01 C02 PRS PC C01 C02 C11 FM C11 PRS P IDF Series 6-4 6 5 IDX-OM-W011 6 IDF15E1-20 L PE N TB ILS CM FM PTC OLR OLR ILS CM PTC PTC PRS TB C11 C11 FM PRS P IDF Series 6-4 6 6 IDX-OM-W011 6 6-5 IDF1E IDF2E / IDF3E IDF4E / IDF6E / IDF8E / IDF11E IDF Series 6-5 6 7 IDX-OM-W011 6 IDF15E1 2 IDF Series 6-5
Refer to page 372 for pivoting bracket. (80, 100) Clevis: CG3DN Bore size Stroke With rubber bumper H S + Stroke L RR V CZ TZ GA GB 8 x J F 2 x P AL A Width across flats NA CDH10 (Hole dia.) C d9 (Shaft dia.)
Specification Specification AMH450 to AMH850 Applicable model AMH150 to AMH850 Applicable model How to Order Refer to "How to Order" for standard type (p.4.6-16). How to Order Refer to "How to Order" for standard type (p.4.6-16).
P: PTFE F: FKM For VCS30 OR-2380-130P P: PTFE F: FKM For VCS40 OR-2600-180P P: PTFE F: FKM Manifold For VCS20 e OR-1400-178P P: PTFE F: FKM OR-2670-178P r P: PTFE F: FKM Wave washer For VCS30, 40 When the loosened clip is pulled out in direction e using pinchers, etc., the coil can be removed and replaced in direction r.
In center position the flo/v P-A, B is as sholn. X X { l ) Series NVFSOO How To Order NVFs lPort size (P,A,B) OXT Y.NPIF O3T %NPTF o4T. _ IbNPIF Typ of I *2 positiqr/singlo solanoid 2 -e position/double eolgnoid l-3 posilion, dGd c6oter/doubl6 solonoid 4 -3 gooidofl extEugt centr/double solenoid 5 -A pEsilion, p.6sure crte./double solenoid oyeride 'Subbas type only.
. 10-12-8 P . 10-12-30 P . 10-12-18 P . 10-12-27 10-12-1 2 Achieve rationalization of production lines with position feedback Stroke reading cylinder Measurement is possible throughout the full stroke range.
. 10-12-8 P . 10-12-30 P . 10-12-18 P . 10-12-27 10-12-1 2 Achieve rationalization of production lines with position feedback Stroke reading cylinder Measurement is possible throughout the full stroke range.
It varies depending on operating pressure.Refer to ''Flow Characteristics" p.4.6-29 and figure of "Max. air flow" p.4.6-28. Removes odor and gas ingredients in compressed air.