SMC Corporation of America
Elite Part Number Search
Search Results "VM123F-04-05"

Number of Ports: 2 Port, Piping Direction, Bar Height: Bottom Ported, Short, Tube O.D.: ø4, Actuator Type: Roller Lever, Suffix: -, Indicator: -, Bracket: -

Number of Ports: 2 Port, Piping Direction, Bar Height: Bottom Ported, Short, Tube O.D.: ø4, Actuator Type: 32 [Push Button (Extended)], Suffix: Push Button Selector Color Black, Indicator: -, Bracket: -

Number of Ports: 2 Port, Piping Direction, Bar Height: Bottom Ported, Short, Tube O.D.: ø4, Actuator Type: 32 [Push Button (Extended)], Suffix: Push Button Selector Color Red, Indicator: -, Bracket: -

Number of Ports: 2 Port, Piping Direction, Bar Height: Bottom Ported, Short, Tube O.D.: ø4, Actuator Type: 33 [Push Button (Flush)], Suffix: Push Button Selector Color Red, Indicator: -, Bracket: -

Number of Ports: 2 Port, Piping Direction, Bar Height: Bottom Ported, Short, Tube O.D.: ø4, Actuator Type: 33 [Push Button (Flush)], Suffix: Push Button Selector Color Yellow, Indicator: -, Bracket: -

NZX is available in standalone or manifold configurations.Vacuum ejector, Stations: 01, 02, 03, 04, 05, 06, 07, 08, Right, left, or both side vacuum supply, NZX MANIFOLD, VACUUM SERIES, ZZX1 MANIFOLD UNIT, JD, ZZX1 1/8 PORTED, .65120 lb

Available in standalone or manifold configurations.Vacuum ejector, Stations: 01, 02, 03, 04, 05, 06, 07, 08, Right, left, or both side vacuum supply, MANIFOLD ASSY, 3-STA, VACUUM EJECTOR, 205 lb

05 06 07 08 09 0A 0B 0C 0D 0E 0F 7seg Display letter 11seg Value (16 Hex number) 10 11 12 13 14 15 16 17 18 19 1A 1B 1C 1D 1E 1F 7seg Display letter 11seg Value (16 Hex number) 20 21 22 23 24 25 26 27 28 29 2A 2B 2C 2D 2E 2F 7seg Display letter 11seg Supplementary information : Do not work Line name communication data -95No.PS-OMW0012-C Maintenance How to reset the product after a power

PF2M7-B.eng:PF2M7-B.eng.qxd 21/04/09 14:02 1 Before Use Digital Flow Switch PF2M7## Wiring Wiring of connector Connections should only be made with the power supply turned off. Use separate routes for the product wiring and any power or high voltage wiring. Otherwise, malfunction may result due to noise.

05 06 07 08 09 0A 0B 0C 0D 0E 0F Display letter 7seg 11seg Value (16 hex number) 10 11 12 13 14 15 16 17 18 19 1A 1B 1C 1D 1E 1F Display letter 7seg 11seg Value (16 hex number) 20 21 22 23 24 25 26 27 28 29 2A 2B 2C 2D 2E 2F Display letter 7seg 11seg Supplementary information When is displayed, a reject response will be sent. -88No.PF-OMZ0002-A Troubleshooting If an operation failure of

05 06 07 08 09 0A 0B 0C 0D 0E 0F Display letter 7seg 11seg Value (16 hex number) 10 11 12 13 14 15 16 17 18 19 1A 1B 1C 1D 1E 1F Display letter 7seg 11seg Value (16 hex number) 20 21 22 23 24 25 26 27 28 29 2A 2B 2C 2D 2E 2F Display letter 7seg 11seg Supplementary information When is displayed, a reject response will be sent. -84No.PF-OMY0002 Troubleshooting If an operation failure of the

05 06 07 08 09 0A 0B 0C 0D 0E 0F number) Display letter 7seg 11seg Value (16 hex 10 11 12 13 14 15 16 17 18 19 1A 1B 1C 1D 1E 1F number) Display letter 7seg 11seg Value (16 hex 20 21 22 23 24 25 26 27 28 29 2A 2B 2C 2D 2E 2F number) Display letter 7seg 11seg -84No.PF-OMX0002-B Troubleshooting If an operation failure of the product occurs, please confirm the cause of the troubles from the

ERR 00: CPU Hung up ERR 01: CPU Check Failure ERR 03: Back-up Data Error ERR 04: EEPROM Writing Error ERR 05: EEPROM Input Over Times Error ERR 11: DC Power Voltage Failure ERR 12: Internal Sensor Value is High ERR 13: Internal Sensor Value is Low ERR 14: Thermostat Alarm ERR 15: Output Failure Alarm (Abnormal output) ERR 17: Cutoff/Short of Internal Sensor ERR 18: Cutoff/Short of External

Specifications of options Model Item IP8101-0252-IP8101-04--M Alarm output1, 210 C Wiring method 2 wire system Corresponding standard DIN19234/NAMUR Standard Power supply voltage 1028VDC 528VDC Load current 1040mADC 11 (Constant Current) Signal status High (Not Active) R=35010 2.1mADC Signal status Low (Active)12 0.5mADC or less 1.2mADC Response time 50msec or less Analog output13, 14 Wiring

BA-05 (A set of band (A set of band (A set of band (A set of band (A set of band and screw) and screw) and screw) and screw) and screw) Note 1) Since the switch bracket (made from nylon) are affected in an environment where alcohol, chloroform, methylamines, hydrochloric acid or sulfuric acid is splashed over, so it cannot be used.

Specifications 6 10 16 20 25 32 Bore size Air Fluid M5x0. 8 Rc1/8 Port size 0. 7Mpa Max. operating pressure 1. 05MPa Without switch: -10 to +70 (No freezing) With switch: -10 to +60 (No freezing) 50 to 500mm/s Proof pressure Ambient and operating fluid temperature Piston speed Double acting D type 0. 0125 Single acting T type 0. 0062 0. 025 0. 05 0. 1 0. 2 0. 3 Allowable kinetic energy

Option Rated voltage Voltage symbol Part no. 100 VAC 100V VK300-82-2-01 110 VAC 110V VK300-82-2-03 200 VAC 200V VK300-82-2-02 Note) When requiring a gauge different than that mentioned above, specify the model number. 220 VAC 220V VK300-82-2-04 Option is packed with it.