MTS Retraction End Body mounting section Table mounting section D E E1 H H Q L G K M B C J A MXS-BT8 P F MXS-BT20 MXS-BT25 MXS-BT8 MXS-BT12 MXS-BT16 N Body mounting section A Table mounting section Applicable size Model B C D E E1 F G H P K L M N Q J MXS8 (L) MXS12 (L) MXS16 (L) MXS20 (L) MXS25 (L) MXS-BT8 (L) 38 23 12.5 14 40.8 5 8 12 1.4 M3 x 12 16.6 7 15.5 14.6 M3 x 16 M8 x 1 MXS-BT12
Union Tee: KPQT, KPGT D 3 x Applicable tubing Effective area mm2 D Model L Applicable tubing O.D. mm Note 1) Weight g M Q TPH TPS 4 L Q M D D KPGT04-00 KPQT04-00 10.4 7 4 4 17 4.5 19.7 6 KPGT06-00 KPQT06-00 12.8 9 10 10 18.5 5.3 21.8 8 KPGT08-00 KPQT08-00 15.2 16 18 26 20.5 6 25.3 4.2 8 10 KPGT10-00 KPQT10-00 18.5 25 29 41 23 6.8 28.4 M M L L 12 KPGT12-00 KPQT12-00 20.9 29 46 58 24 7.5 30.4
Negative common specifications L dimension 2-4-93 Series VQ Construction: VQ1000/Plug Lead Unit, Cassette Type Metal seal Single/Double (Latching) Rubber seal Single/Double (Latching) L plug connector L plug connector 3 position 3 position L plug connector L plug connector Component Parts Component Parts Note q Note q Material Material No. Description No.
How to find the flow rate for water Formula based on Cv factor Q = 14.2 Cv 10.2 P l/min Formula based on effective area (Smm) Q = 0.8 S 10.2 P l/min Q: Flow rate (l/min), P: Pressure differential (P1P2), P1: Upstream pressure (MPa) P2: Downstream pressure (MPa), S: Effective area (mm), Cv: Cv factor 17 Compact Direct Operated Series VDW 2/3 Port Solenoid Valve for Water and Air Safety
How to find the flow rate for water Formula based on Cv factor Q = 14.2 Cv 10.2 P l/min Formula based on effective area (Smm) Q = 0.8 S 10.2 P l/min Q: Flow rate (l/min), P: Pressure differential (P1P2), P1: Upstream pressure (MPa) P2: Downstream pressure (MPa), S: Effective area (mm), Cv: Cv factor 17
XLGV/With solenoid valve Q Port R (exhaust port) N N With double solenoid P K M L (mm) L 6.5 6.5 6.5 11 11 11 K 9 9 9 11 11 11 N 14 Model K L M N P Q M 17 15 2 6 Q 16.5 16.5 17.5 28 29 29 P Model XLGV-16 XLGV-25 XLGV-40 XLGV-50 XLGV-63 XLGV-80 3 3 3 6.5 6.5 6.5 16 With single solenoid Port P (pressure port) 29 26 32 45 Other dimensions are the same as XLG. 19 Series XLD, XLDV Smooth Exhaust
CQSB12-L-PS CQSB16-L-PS CQSB20-L-PS CQSB25-L-PS Contents Set of nos. above , , Seal kit includes , , . Order the seal kit, based on each bore size. (The long stroke type includes 2 tube gaskets.) Since the seal kit does not include a grease pack, order it separately.
XLGV/With solenoid valve Q Port R (exhaust port) N N With double solenoid P K M L (mm) L 6.5 6.5 6.5 11 11 11 K 9 9 9 11 11 11 N 14 Model K L M N P Q M 17 15 2 6 Q 16.5 16.5 17.5 28 29 29 P Model XLGV-16 XLGV-25 XLGV-40 XLGV-50 XLGV-63 XLGV-80 3 3 3 6.5 6.5 6.5 16 With single solenoid Port P (pressure port) 29 26 32 45 Other dimensions are the same as XLG. 19 Series XLD, XLDV Smooth Exhaust
AS120M AS220M-01 AS220M-02 Inlet pressure: 0.5 MPa Inlet pressure: 0.5 MPa Inlet pressure: 0.5 MPa 10 20 50 Flow rate (L/min (ANR)) Flow rate (L/min (ANR)) Flow rate (L/min (ANR)) 40 30 5 10 20 10 0 5 0 5 20 10 10 0 10 Number of needle rotations Number of needle rotations Number of needle rotations Construction Meter-out type AS1200M AS2200M u w u w t e r !0 !1 i q !4 r e !0 !1 q i !
Modify the detecting position while the auto switch is secured at the position of (3) in the figure. a Auto switch mounting screw M3 x 0.5 x 8 L (For BQ-1) Auto switch Set screw (Unused) r u t c e y Auto switch mounting bracket d Auto switch mounting screw M2.5 x 0.45 x 6 L b Square nut (For BQ-1) w Cylinder q BQ-1 and BMU1-025 are a set of a and b shown above.
(mm) Note) D1 D2 L I Q M Nylon Urethane KGUD04-01 1 8 17 25 43.5 47 50.5 53.5 21 39.5 41 13 10.4 4.2 4.2 9.7 16 10.4 12.8 4 1 4 KGUD04-02 14 1 8 1 4 KGUD06-01 KGUD06-02 26 46.5 47.5 11.7 17 13.4 10.6 12.8 12.8 15.2 6 29 17 Reference dimensions after R thread installation.
4 x OB counterbore depth OL L (OL) 4 x NN through U X PW PE VA 2 x P (Plug) H R T 2 x P D GB GC S Q 2 x P (Plug) GA JC PD C + Stroke FB FA K J G A + Stroke [mm] Bore size Standard stroke A C D FA FB G GA GB GC GD H J JC K L MM ML NN Nil TN TF 20 (16 x 2) 20, 30, 50 100, 150 38 27.5 8 7.5 3 22 12.5 7.5 11 83 11 3 11 14 M4 x 0.7 10 M4 x 0.7 25 (20 x 2) 39.5 28 10 8.5 3 26 12 7.5 11 93
10 100 -X Eccentric distance L (mm) 507 MGPW Series L L m m Horizontal Mounting Slide bearing MGPWM20 to 63 (17) L = 50 mm, V = 200 mm/s or less (18) L = 100 mm, V = 200 mm/s or less 100 100 Load mass m (kg) Load mass m (kg) 50, 63 50, 63 50, 63 50, 63 32, 40 32, 40 10 10 32, 40 32, 40 25 25 25 20 25 20 20 20 1 1 10 100 50 51 200 10 100 50 51 200 Stroke (mm) Stroke (mm) (19) L = 50 mm, V
Note 3) Weight without sub-plate 1.12-7 VQZ1000/2000/3000 Body Ported Construction: VQZ1000/2000/3000 Metal seal Rubber seal e w q r e w q r 2 position single 2 position single (A) 4 (B) 2 (A) 4 (B) 2 5 (R1) 1 (P) 3 (R2) 5 (R1) 1 (P) 3 (R2) e w q r e w q r 2 position double 2 position double (A) 4 (B) 2 (A) 4 (B) 2 5 (R1) 1 (P) 3 (R2) 5 (R1) 1 (P) 3 (R2) e w q e w q 4 r 3 position pressure
B RATE PWR L RUN SETTINGS MOD/NET ADDRESS NO. PWR PWR COM ERR ON ON L ERR.
N.O. q IFW50--75/76 e Color of lead wire Black Symbol Contact q w Power supply (Common) w Red Terminal (Relay terminal) 24 VDC Gray e Power supply (Light terminal) N.O. N.C. q IFW50--85/86 e Color of lead wire Black Symbol Contact q w Power supply (Common) White Terminal (Relay terminal) w 24 VDC Gray e Power supply (Light terminal) N.C. N.O.
l /min How to find the flow rate for water 5.0 Formula based on Cv factor Q = 14.2 Cv 10.2 P l/min Formula based on effective area (Smm) VCB 3 Cv = 0.35 3 4 1.0 Q = 0.8 S 10.2 P l/min VCB23 Cv = 0.33 VCB25 Cv = 0.65 Q: Flow rate (l/min) P:Pressure differential (P P) P: Upstream pressure (MPa) P: Downstream pressure (MPa) S: Effective area (mm) Cv: Cv factor VCB34 Cv = 0.54 VCB24
l /min How to find the flow rate for water 5.0 Formula based on Cv factor Q = 14.2 Cv 10.2 P l/min VCB 3 Cv = 0.35 3 4 Formula based on effective area (Smm) 1.0 Q = 0.8 S 10.2 P l/min VCB23 Cv = 0.33 VCB25 Cv = 0.65 Q: Flow rate (l/min) P:Pressure differential (P P) P: Upstream pressure (MPa) P: Downstream pressure (MPa) S: Effective area (mm) Cv: Cv factor VCB34 Cv = 0.54 VCB24
MX MTS MY Centralized piping on right CY MG CX R R L DL -X R L Slide table actuation direction 20Centralized piping on left Data R L L R R L Slide table actuation direction 4. Never disassemble the magnetic component parts (external slider, internal slider) of the actuator (cylinder). If will cause decline of the holding force, etc. 2.