Rated Vacuum Range: -101 to 0 kPa, Output Specification: NPN Open Collector 2 Outputs + Copy Function, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: 02 [R1/4, (M5, Female Threaded)], Piping Direction: Rear Ported, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: -, Operation Manual:
Rated Vacuum Range: -101 to 0 kPa, Output Specification: NPN Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: 02 [R1/4, (M5, Female Threaded)], Piping Direction: Rear Ported, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: -, Operation
Rated Vacuum Range: -101 to 0 kPa, Output Specification: PNP Open Collector 2 Outputs + Copy Function, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: 02 [R1/4, (M5, Female Threaded)], Piping Direction: Rear Ported, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: Bracket A, Operation
Rated Vacuum Range: -101 to 0 kPa, Output Specification: PNP Open Collector 2 Outputs + Analog Current Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: 02 [R1/4, (M5, Female Threaded)], Piping Direction: Rear Ported, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: Panel Mount
V Ps + 0.1 293 S = 12.1 log10 () (6) t P + 0.1 T S : Effective area [mm2] V : Air tank capacity [dm3] t : Discharging time [s] Ps : Pressure inside air tank before discharging [MPa] P : Residual pressure inside air tank after discharging [MPa] T : Temperature inside air tank before discharging [K] Power supply Thermometer Pressure switch Control circuit Solenoid valve Pressure control equipment
Thread type VT307 manifold Nil F N T Rc G NPT NPTF Valve stations 02 2 stations 20 20 stations A port size (Base mounted) Max. 20 stations 01 02 common exhaust/individual exhaust 1 8 individual exhaust 1 4 Specify model number of the manifold base, applicable valves and blanking plates when ordering. Refer to page 1 for the model number of the valves.
Q = T x L x x C 860 Q = T x L x x C 60 x 1000 6.0 x 1.2 x 1.80 x 103 x 0.23 860 = 6.0 x 20 x 1.80 x 103 x 0.96 x 103 = = 3.5 kW 60 x 1000 = 3456W = 3.5 kW Cooling capacity = Considering a safety factor of 20%, 3.5 x 1.2 = 4.2 kW Cooling capacity = Considering a safety factor of 20%, 3.5 x 1.2 = 4.2 kW Thermo-chiller T2: Return temperature Customers machine L T =T2 T1 T1: Outlet temperature
AW-OMS0038-C PRODUCT NAME FILTER REGULATOR MODEL/ Series AW20-(F,N)01(F,N)02(B,C,E,G,H,M)(-1,2,6,C,J,N,R,Z)-B AW30-(F,N)02(F,N)03(B,C,D,E,G,H,M)(-1,2,6,8,J,N,R,W,Z)-B AW40-(F,N)02(F,N)04(B,C,D,E,G,H,M)(-1,2,6,8,J,N,R,W,Z)-B AW40-(F,N)06(B,C,D,E,G,H,M)(-1,2,6,8,J,N,R,W,Z)-B AW60-(F,N)06(F,N)10(B,C,D,E,G,M)(-1,2,6,8,J,N,R,W,Z)-B Contents PAGE 1. SAFETY INSTRUCTIONS 16 2. APPLICATION 7 3.
Suitable for use in vacuum applications 101.2 kPa (For vacuum specifications type: VT/VO325V) 02 1 G VT325 SY Thread type SYJ Nil F N T Rc G NPT NPTF For manifold: Enter VO.
AW-OMT0013-B PRODUCT NAME FILTER REGULATOR MODEL/ Series AW20K-(F,N)01(F,N)02(B,C,E,G,H,M)(-1,2,6,C,J,N,R,Z)-B AW30K-(F,N)02(F,N)03(B,C,D,E,G,H,M)(-1,2,6,8,J,N,R,W,Z)-B AW40K-(F,N)02(F,N)04(B,C,D,E,G,H,M)(-1,2,6,8,J,N,R,W,Z)-B AW40K-(F,N)06(B,C,D,E,G,H,M)(-1,2,6,8,J,N,R,W,Z)-B AW60K-(F,N)06(F,N)10(B,C,D,E,G,M)(-1,2,6,8,J,N,R,W,Z)-B Contents PAGE 1. SAFETY INSTRUCTIONS 16 2.
Bore size (mm) Bore size (mm) AS2000-01/02 AS600-10 Piping bore Piping bore Cylinder driving speed (mm/s) Cylinder driving speed (mm/s) No load No load No load No load Load ratio Load ratio Bore size (mm) Bore size (mm) AS4000-02/03/04 AS3000-02/03 Piping bore Piping bore Cylinder driving speed (mm/s) Cylinder driving speed (mm/s) Circuit diagram No load No load No load No load Load ratio
t Plug } IN OUT OUT IN q o q Plug y Purge air for dehumidification u Plug u Purge r Purge Purge air for dehumidification Component Parts Material Description No.
Applicable model 02 03 04 06 10 1/4 3/8 1/2 3/4 1 8 3 Pressure gauge 3 4 5 6 1 AMR300-02/03 AMR400-02 to 04 AMR500-04 to 06 AMR600-10 3 4 5 6 1 2 Nil E2 E3 E4 E6 E10 None None With pressure switch S Nil 4 3 1/4 3/8 1/2 3/4 1 Port size Adapter assembly Thread type Symbol Port size Nil N F Rc NPT G Thread type 02 03 04 06 10 1/4 3/8 1/2 3/4 1 The port size of adapter assembly is same as the
LVQ Model VXA212 VXA213 VXA21 VXA22 VX070-020 LQ 1 8 1 4 1 4 3 8 1 2 01 ( / ) 02 ( / ) 02 ( / ) 03 ( / ) 04 ( / ) VXA223 VXA224 VXA225 VXA226 VX070-022 LVN VX070-029 TI/ TIL PA Ordering example (Example) Series VXA21, Orifice size 4.5 mm, Normally closed, Rc 1/4 (Part no.) VXA2130-02 PAX PB 17-3-95 4 The VX series will be revised shortly.
Applicable model 02 03 04 06 10 1/4 3/8 1/2 3/4 1 8 3 Pressure gauge 3 4 5 6 1 AMR300-02/03 AMR400-02 to 04 AMR500-04 to 06 AMR600-10 3 4 5 6 1 2 Nil E2 E3 E4 E6 E10 None None With pressure switch S Nil 4 3 1/4 3/8 1/2 3/4 1 Port size Adapter assembly Thread type Symbol Port size Nil N F Rc NPT G Thread type 02 03 04 06 10 1/4 3/8 1/2 3/4 1 The port size of adapter assembly is same as the
Mounting hole T(M) L1 L2 Nylon Urethane 1 8 KGE04-01 16 35 25 40 29 14 16 27.5 31 28 31.5 33.5 27.5 33 11 15 11 15 17 7.5 13 4 M12 1 13 5.6 5.6 14 1 4 KGE04-02 17 1 8 1 4 3 8 1 8 KGE06-01 KGE06-02 KGE06-03 KGE08-01 17 6 M14 1 13.1 13.1 17 15 17 19 26.1 18.0 28 27 48 17 1 4 KGE08-02 M16 1 8 18.5 17 19 3 8 KGE08-03 15 19 35 1 4 KGE10-02 34.5 36.5 41.5 29.5 53 67 12.5 14 10 21 M20 1 21 22 24
Mounting hole T(M) L1 L2 Nylon Urethane 1 8 KGE04-01 16 35 25 40 29 14 16 27.5 31 28 31.5 33.5 27.5 33 11 15 11 15 17 7.5 13 4 M12 1 13 5.6 5.6 14 1 4 KGE04-02 17 1 8 1 4 3 8 1 8 KGE06-01 KGE06-02 KGE06-03 KGE08-01 17 6 M14 1 13.1 13.1 17 15 17 19 26.1 18.0 28 27 48 17 1 4 KGE08-02 M16 1 8 18.5 17 19 3 8 KGE08-03 19 15 35 1 4 KGE10-02 34.5 36.5 12.5 14 41.5 29.5 53 67 10 21 21 M20 1 22 24
Type T: 4.5 to 7 mm Type E: 2.3 to 2.8 mm Type D: 6 to 8 mm Applicable crimp terminal Type E/T: 1.25-3, 1.25-3S 1.25Y-3N, 1.25Y-3S Round or Y shaped crimped terminals can be not used for type D.
Check using a feeler gauge that the clearance between the position indicator (109) and the electronics cover is 1 mm. 7 ND90 71 en 17 N O I T A C O L S U O D R A Z A H N O I T A C O L S U O D R A Z A H N O N ND9000H Valve Positioner Position Transmitter X300 Ui (Vmax) = 28 V Ii (Imax) = 120 mA Pi (Pmax) = 1 W Li = 53 uH Ci = 22 nF Ex i Barrier + 1 Uo (Voc) 28 V Io (Isc) 120 mA Po 1 W
V Ps + 0.1 293 S = 12.1 log10 () (6) t P + 0.1 T S : Effective area [mm2] V : Air tank capacity [dm3] t : Discharging time [s] Ps : Pressure inside air tank before discharging [MPa] P : Residual pressure inside air tank after discharging [MPa] T : Temperature inside air tank before discharging [K] Power supply Thermometer Pressure switch Control circuit Solenoid valve Pressure control equipment