VVT34 Porting specifications 1 0 05 V100 Thread type Port size Nil F N T Rc G NPT NPTF Symbol R Bottom Side P Side Side A SY Symbol Port size 1 0 Side Side 02 1 4 03 3 8 SYJ Instruct by specifying the valves and blanking plate to be mounted on the manifold along with the manifold base model no.
bottom ported Type V Port size Rc EXH port Valve size Applicable valve Manifold base size Rc P EA, EB A, B , 1 4 3 8 1 4 3 8 1 4 3 8 3 8 1 2 3 8 1 2 1 2 1 2 VSA420 Common EXH , 3 8 1 2 , 1 4 3 8 , 3 8 1 2 , 3 8 1 2 3 8 standard 1 4 3 8 VSA430 Individual EXH 1 2 VSA430 3 4 3 4 Common EXH , 1 2 3 4 How to Order 1 2 standard , 1 2 3 4 , 3 8 1 2 3 8 VSA440 3 4 Individual EXH 1 2 SA VV 4 2 0 N 1 05
AN103-01 AN203-02 AN303-03 AN403-04 5-10-3 4 Silencer Metal Case Type Series 25 How to Order Exhaust in only one direction Prevents scattering of mist and noise. 25 10 002 Port size Thread type Body size 002 003 004 006 010 1/4 3/8 1/2 3/4 1 R NPT Nil N 04 05 06 07 08 10 11 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside
Series LVH is a manually operated valve, available in a threaded or integral fitting type.Manually operated, integral fitting valve, Body class: 2 (ø4 orifice dia.), 3 (ø8 orifice dia.), 4 (ø10 orifice dia.), Normally closed (N.C.), Applicable tubing size: 03 (ø3), 04 (ø4), 06 (ø6), 08 (ø8), 10 (ø10), 12 (ø12), 03 (1/8"), 05 (3/16"), 07 (1/4"), 11 (3/8"), 13 (1/2") HIGH PURITY CHEMICAL VALVE
Stations: 05 (5 Stations), Exhaust: 1 (Complex Exhaust), Bracket: B (With DIN rail mounting bracket), Individual Release Pressure Supply: None, Manifold Individual Supply: None, Manifold End Plate Assembly: A
Nominal filtration rating: 30 m 0 to 101 kPa 100 to 100 kPa 849 Compact Vacuum Ejector Series ZA How to Order Ejector Unit ZA1 1 07 K1 P1 5 L 0 1 Nozzle nominal size Vacuum (V) port 05 07 0.5 0.7 Symbol 1 2 4 5 Applicable tubing O.D. Part no. KJS23-M5 KJS04-M5 KJL23-M5 KJL04-M5 3.2 (Straight) 4 (Straight) 3.2 (Elbow) 4 (Elbow) Solenoid valve combination (Refer to Table (1).)
SS5V 05 Station Manifold, Tie-Rod Base. 0.51000 lb. VVM.
Series: SS5Y3 (SY3000 Manifold), Model: 10S (Side-Ported, Serial Interface), SI Unit Specification: EB (EtherNet/IPâ„¢ - 16 Outputs - Connector M12), SI Unit Output Polarity: N (PNP), Valve Stations: 05 Stations, P, E Port Location: D (D Side), SUP/EXH Block: Internal Pilot, A, B Port Size: N7 (ø1/4" One-touch Fitting), Mounting: D (DIN Rail Mounting w/o Name Plate, w/o Station Number)
Series: SS5Y3 (SY3000 Manifold), Model: 10S (Side-Ported, Serial Interface), SI Unit Specification: EA (EtherNet/IPâ„¢ - 32 Outputs - Connector M12), SI Unit Output Polarity: N (PNP), Valve Stations: 05 Stations, P, E Port Location: D (D Side), SUP/EXH Block: S (Internal Pilot, Built-in Silencer), A, B Port Size: C4 (ø4 One-touch Fitting), Mounting: D (DIN Rail Mounting w/o Name Plate, w/
SS5V 05 Station Manifold, Tie-Rod Base. 837.50000 lb. VVD.
Series LVH is a manually operated valve, available in a threaded or integral fitting type.Manually operated, integral fitting valve, Body class: 2 (ø4 orifice dia.), 3 (ø8 orifice dia.), 4 (ø10 orifice dia.), Normally closed (N.C.), Applicable tubing size: 03 (ø3), 04 (ø4), 06 (ø6), 08 (ø8), 10 (ø10), 12 (ø12), 03 (1/8"), 05 (3/16"), 07 (1/4"), 11 (3/8"), 13 (1/2") HIGH PURITY CHEMICAL VALVE
Stations: 05 (5 Stations), Piping: D (U Side: Closed; D Side: Open), Thread Type: Rc, Supply Unit Components: P (w/o Flow Adj. Valve; w/Stop Valve), Return Unit Flow Switch: 5 (Remote Sensor Unit), Return Unit Flow Range: 20 (2 to 16 L/min), Return Unit Components: W (w/Flow Adj.
Stations: 05 (5 Stations), Supply/Return Unit Layout: D (U Side: Open; D Side: Open), Thread Type: N (NPT), Supply Unit Components: Flow Adj. Valve: None; Stop Valve: None, Return Unit Flow Switch: 7 (Integrated Display), Return Unit Flow Range: 40 (5 to 40 L/min), Return Unit Components: S (w/Flow Adj.
Nozzle Diameter: 05 (0.5), Body Type: 1U (for Single Unit), Solenoid Valve Combination: K1 (Supply Valve: N.C., Release Valve: N.C.), Voltage: 5 (24 VDC), Electrical Entry: LO [L Plug Connector (w/o Connector), w/Light/Surge Voltage Suppressor}, Manual Override: Non-locking, Push Type, Vacuum Pressure Switch Suction Filter: VA (-100 to 100; NPN 1 Output + Energy Saving Function), Unit: M
Series: SS5Y3 (SY3000 Manifold), Model: 10S (Side-Ported, Serial Interface), SI Unit Specification: KA (IO-Link - 32 Outputs - Connector M12), SI Unit Output Polarity: N (PNP), Valve Stations: 05 Stations, P, E Port Location: B (Both Sides), SUP/EXH Block: S (Internal Pilot, Built-in Silencer), A, B Port Size: C6 (ø6 One-touch Fitting)
Pad Connection Thread: BG1BG1 (G1/8), Orifice Size: 05 (0.5 mm)
Rated Flow Range: 05 (0.05 to 5 L/min), Flow Adjustment Valve: None (Straight), Port Size: C4 (ø4), Output Specification: B (Out 1: PNP; Out 2: PNP), Lead Wire: Lead Wire w/Connector, Unit Specification: Unit Selection Function, Bracket/Panel Mount Adapter: R (Bracket, w/o Flow Adjustment Valve)
Rated Flow Range: 05 (0.05 to 5 L/min), Flow Adjustment Valve: None (Straight), Port Size: N1 (NPT1/8), Output Specification: F (Out 1: PNP; Out 2: Analog 4 to 20 mA), Lead Wire: W (Lead Wire w/Connector + Rubber Cover for Connector), Unit Specification: Unit Selection Function, Bracket/Panel Mount Adapter: No Bracket, Calibration Certificate: A (Calibration Certificate)
Size: 05 (ODØ3/16" IDØ0.13"), Color: BU3 (Medium Blue), Roll Length: 33 (100 ft)
Nozzle Diameter: 05 (0.5), Body Type: 3M (for Manifold), Solenoid Valve Combination: K1 (Supply Valve: N.C., Release Valve: N.C.), Voltage: 5 (24 VDC), Electrical Entry: LO [L Plug Connector (w/o Connector), w/Light/Surge Voltage Suppressor}, Manual Override: B (Locking Slotted Type), Vacuum Pressure Switch Suction Filter: VB (-100 to 100; PNP 1 Output + Energy Saving Function), Unit: w/Unit