SMC Corporation of America
Elite Part Number Search
Search Results "PF2D504-11-1-C"

No.LV20***-OMY0005 / / / / / / / / LVA/LVC 1 P2 2 P34 3LVC P56 4LVC () P7 5LVA P89 6LVA () P10 7 P11 8 P12 9 P13 1 2 3 4 5 6 7 8 9 10 11 12 13 4-14-1, Sotokanda, Chiyoda-ku, Tokyo 101-0021 JAPAN Tel: + 81 3 5207 8249 Fax: +81 3 5298 5362 URL https://www.smcworld.com Note: Specifications are subject to change without prior notice and any obligation on the part of the manufacturer. 2020

Series LVH is a manually operated valve, available in a threaded or integral fitting type.Manually operated, integral fitting valve, Body class: 2 (ø4 orifice dia.), 3 (ø8 orifice dia.), 4 (ø10 orifice dia.), Normally closed (N.C.), Applicable tubing size: 03 (ø3), 04 (ø4), 06 (ø6), 08 (ø8), 10 (ø10), 12 (ø12), 03 (1/8"), 05 (3/16"), 07 (1/4"), 11 (3/8"), 13 (1/2") HIGH PURITY CHEMICAL VALVE

Body Size: 6 (1/2 Basis), Port Size: N04 [Cylinder Side (NPT 1/2) Pilot Port (NPT 1/4)], Applicable Tube OD: 11 (Ø3/8")

Function: 1 (2 Position Single), Body Option: 11 (Non Plug-in Type Sub-plate, Direct Manual Override), Pilot Type: Internal Pilot, Voltage: 5 (24VDC), Lead Wire: D (DIN Connector), Surge Suppressor: Z (Light & Surge Suppressor), Port Size: 10 (Sub-plate Plug-in Terminal 1, Non Plug-in Standard 1), Thread: N (NPT)

Available in thread sizes from M3 to 1/2 in both inch (NPT) and metric R(PT) and with tube sizes from 3.2mm to 12mm OD (metric) and 1/8 to 1/2 OD (inch) and with optional elbow and universal style (increased flexibility) and meter-in and meter-out, these speed controls are designed to meet most applications.

Available in thread sizes from M3 to 1/2 in both inch (NPT) and metric R(PT) and with tube sizes from 3.2mm to 12mm OD (metric) and 1/8 to 1/2 OD (inch) and with optional elbow and universal style (increased flexibility) and meter-in and meter-out, these speed controls are designed to meet most applications.

Available in thread sizes from M3 to 1/2 in both inch (NPT) and metric R(PT) and with tube sizes from 3.2mm to 12mm OD (metric) and 1/8 to 1/2 OD (inch) and with optional elbow and universal style (increased flexibility) and meter-in and meter-out, these speed controls are designed to meet most applications.

Available in thread sizes from M3 to 1/2 in both inch (NPT) and metric R(PT) and with tube sizes from 3.2mm to 12mm OD (metric) and 1/8 to 1/2 OD (inch) and with optional elbow and universal style (increased flexibility) and meter-in and meter-out, these speed controls are designed to meet most applications.

Port sizes range from 1/8 to 1/2 with Rc(PT), NPTF and G(PF) thread types available. Various options also available.

Port sizes range from 1/8 to 1/2 with Rc(PT), NPTF and G(PF) thread types available. Various options also available.

In addition, SMC now offers a light weight, large capacity mini ISO valve (size 01).Manifold for series VSR/S8-4 valves (size 01), Conforms to ISO 15407-2 , 1 to 12 stations as standard (depending on S kit) , G port thread is applicable to ISO 1179-1, MFLD, ISO, 11-STA, VALVE, VV81* MFLD ISO SERIES, QM, VV81* BASE MT 3/8, 11.02311 lb

Please contact us for the latest version.sales@ocaire.com, SOLENOID COIL FOR VCS40, VALVE, VC* VALVE, 2-PORT SOLENOID, 11, VC* OTHER SIZE RATING, .33660 lb, ModelClassNote 1)Port sizeNote 1)Orificediameter (mm?)

Rated Control Flow Range: 11 (1 to 100 L/min), Port Size: N7 (1/4 inch), Input/Output Specification: 2 (Input: Analog 4 to 20mA, Output 1:IO-Link/NPN/PNP, Output 2: Analog Output 4 to 20mA), Wire Connector: With lead wire with connector (3 m/5 core), Unit Specification: M (SI units only), Bracket: R (Bracket (mounting position: Side)

Rated Control Flow Range: 11 (1 to 100 L/min), Port Size: N2 (1/4 NPT), Input/Output Specification: 2 (Input: Analog 4 to 20mA, Output 1:IO-Link/NPN/PNP, Output 2: Analog Output 4 to 20mA), Wire Connector: Q (M12-M12 lead wire with connector (3 m/5 core)), Unit Specification: M (SI units only), Bracket: S (Bracket (mounting position: Stream side))

Rated Flow Range: 11 (1 to 100 L/min), Flow Adjustment Valve: S (With Flow Adjustment Valve, Straight), Port Size: C8 (ø8), Output Specification: E (Out 1: PNP; Out 2: Analog 1 to 5 V - Analog 0 to 10 V)

Rated Flow Range: 11 (1 to 100 L/min), Flow Adjustment Valve: None (Straight), Port Size: N2 (NPT1/4), Output Specification: L3 (Out 1: IO-Link or NPN/PNP, Out 2: Analog 1-5V), Lead Wire: Q (w/M12 Conversion Lead Wire and Connector, 0.1m)

Rated Flow Range: 11 (1 to 100 L/min), Flow Adjustment Valve: S (With Flow Adjustment Valve, Straight), Port Size: N2 (NPT1/4), Output Specification: L3 (Out 1: IO-Link or NPN/PNP, Out 2: Analog 1-5V), Lead Wire: Q (w/M12 Conversion Lead Wire and Connector, 0.1m)

Rated Flow Range: 11 (1 to 100 L/min), Flow Adjustment Valve: S (With Flow Adjustment Valve, Straight), Port Size: N2 (NPT1/4), Output Specification: E (Out 1: PNP; Out 2: Analog 1 to 5 V - Analog 0 to 10 V), Lead Wire: Lead Wire w/Connector, Unit Specification: Unit Selection Function, Bracket/Panel Mount Adapter: S (Bracket, w/Flow Adjustment Valve)

Rated Flow Range: 11 (1 to 100 L/min), Flow Adjustment Valve: S (With Flow Adjustment Valve, Straight), Port Size: N2 (NPT1/4), Output Specification: L3 (Out 1: IO-Link or NPN/PNP, Out 2: Analog 1-5V), Lead Wire: Lead Wire w/Connector, Unit Specification: Unit Selection Function, Bracket/Panel Mount Adapter: S (Bracket, w/Flow Adjustment Valve)