1.5 1.2 3.2 1/8, 1/4 1/4, 3/8 1/4, 3/8, 1/2 3/4 3/4, 1 1/8 1/8 1/8 1/8 1/8 M28 x 1 M38 x 1.5 M42 x 1.5 M42 x 1.5 26 29.4 37.3 37.3 43.3 Note) The dimension of C is the length when the filter regulator knob is unlocked. 1081 A 1021-AW K-B Regulator with Backflow Function Dimensions J J D M N T AW20K-B 1021Bracket (Option) S U Panel fitting dimension Air Preparation Equipment Pressure Control
Recommended tightening torque Auto switch model Recommended tightening torque [Nm] D-M9 0.05 to 0.15 D-M9A (Water resistant) 0.05 to 0.10 Fig. 8 D-F8 0.10 to 0.20 Set screw Auto switch 29 - Auto switch proper mounting position at rotation end Table 11 Auto Switch Rotation range / Actuation / most sensitive position A A A A B B B B D-M9 D-F8 Magnet Operation range at optimum set position (
Enter in order starting from the first station on the D side. Stations U side D side 2 stations 02 VVQ1000-10A-2 Stations4321 20 stations 20 Port size and thread M5, Rc 1/8 NPT 1/8 NPTF 1/8 PF 1/8 Nil 01N 01T 01F Only thread port size 1/8 type, (Type 2U, P/E port) has choice of thread.
8 Note) 3/16", 3/8" and 1/2" are made of stainless steel 303.
7 + + + + + + 8 I/O (NPN/PNP) 9 10 FG () 12 - 3.3. 1LECA6 2DIN LECA6D 13 - 3.4. 1 DIN 2 LECA6 DINLECA6D DIN 2M4 DIN DIN A DIN ADIN 2 M4 M4 14 - D (100 ) 2mm 2 D 3 40 30mm 50mm ()60mm 0mm (LE)10mm 25 LEH () 30mm 60mm 30mm 50mm DIN ) 15 - 4.
Recommended tightening torque for spacer and spacer with bracket Unit: N m Spacer with bracket Holding screw Model AR20S AR30S AR40S AR50S Spacer with bracket Y200T-2-D Y300T-2-D Y400T-1-D Y600T-2-D Spacer Y200-D Y300-D Y400-D Y600-D Torque 0.360.036 1.20.05 1.20.05 2.00.1 7. There are no piping threads on the OUT port of this product. 6 - Wiring Warning 1.
Note 5) 3/16", 3/8", 1/2"are made of brass AS131F (3.2, 4, 6, 1/8", 5/32, 1/4), AS231F-01(3.2, 4, 6, 1/8", 5/32) are POM. 15-9-5 5 Series AS Elbow Type M3 port M5 port U10/32 port Applicable tubing O.D. d (Hexagon width across flats) Applicable tubing O.D. d (Hexagon width across flats) Metric Size Inch Size Applicable tubing O.D. d 1/8" Applicable tubing O.D. d A(2) Weight (g) T D1 H(1)
81.7 H KKA6S-03M-1 R 3/8 51.4 44.9 138.3 L -04M-1 1/2 R 1/2 11.4 81.6 54.4 46.4 149.6 30 30.7 -06M-1 R 3/4 56.4 46.9 174.0 Female thread type (mm) Body size H Width across flats Min. bore size Model T Connection port size Weight g Effective area mm2 L D KKA3S-01F-1 Rc 1/8 44.5 37.6 T 17 -02F-1 1/8 Rc 1/4 18.5 6.1 23.4 44.8 41.2 -03F-1 Rc 3/8 49.9 43.1 19 D KKA4S-02F-1 Rc 1/4 46.1 92.2 22
Pin Cylinder Series C(D)JP 1.2-2 20-CJP Double acting SCJPl 1.2-8 20-CJP Single acting Large bore size cylinder Series C(D)S1 Standard SC51l 1.10-2 20-CS1N Fine lock cylinder Series C(D)L RB Standard SCLAl 3.1-33 20-CLA J Cylinder with lock Series C(D)NA D SCNAl Standard 20-C(D)NA 3.3-1 -X End lock cylinder Series C(D)B 20Standard 20-CBM2 SCBM2l 3.4-4 Standard 20-CBA1 SCBA1l 3.4-12 Plate
Hardware Specication 2.1 Available Models PneuAlpha Hardware Specification 2 ECC-PNAL-20MT-D 12 TRANSISTOR 8 ECC-PNAL-10MT-D 6 TRANSISTOR 4 (0.70)* ECC-PNAL-20MR-D ECC-PNAL-20MR-A 100 240V AC~ 100 240V AC~ 12 RELAY 8 124.6 x 90 x 55 ECC-PNAL-10MR-D ECC-PNAL-10MR-A 6 RELAY 4 ECC-PNAL-6MR-A 100 240V AC~ 100 240V AC~ 4 RELAY 2 71.2 x 90 x 55 Model Power Supply * Without Special Connection Modules
T) 72.5 (DIN terminal: D) Bracket 2-M4 x 0.7 depth 7 Main port Rc Model VNA1-6A VNA1-8A VNA1-10A 1 8 1 4 3 8 In the case of EZ or TZ, the length is longer by 10 mm.
Solenoid Specifications Apparent power (VA) Inrush Holding Power consumption (W) (Holding) Temperature rise (C ) (Rated voltage) Frequency (Hz) 50 25 12 60 20 8 Model Power source 5 50 3.5 35 6 50 8 55 6.5 45 8 50 0.5 60 9.5 50 11.5 55 Note) They are values in an ambient temperature of 20C 5C and application of rated voltage.
Solid state switch Model D-F8 Series Variations Bore size (mm) Rod end configuration Stroke (mm) Clean room series 4 6 8 10 15 20 Action Series Auto switch Double acting Male thread Without thread Nil 4 Single acting (spring return) Double acting 6 Single acting (spring return) CUJ Solid state switch D-F8 D-F9 Female thread Double acting 8 Male thread Single acting (spring return) Double
10 6 8 10 12 12 10 6 8 10 Tubing O.D.
Grade 2 Grade 2 Rubber stopper Grade 4 Grade 4 Metal stopper Auto switches / Proper mounting position for stroke end detection 11-/22MXP6 A A C D D B Reed switch D-A93 Solid state switch D-M9B, D-M9N Stroke (mm) Auto switch operating range 10 34.5 35.5 14.5 15.5 Stroke (mm) Auto switch operating range 10 30.5 31.5 18.5 19.5 Model Model 5 25.5 26.5 13.5 14.5 A B C D A B C D 11-/22-MXP 6
D B Reed auto switch D-A93 Solid state auto switch D-M9B, D-M9N Stroke (mm) Auto switch operating range 10 34.5 35.5 14.5 15.5 Stroke (mm) Auto switch operating range 10 30.5 31.5 18.5 19.5 Model Model 5 25.5 26.5 13.5 14.5 A B C D A B C D 11-/22-MXP6 5 11-/22-MXP6 3 11-/22-MXP10, 12, 16 Electrical entry from outside Electrical entry from inside Parallel electrical entry B A B B A A Solid
U A 38.2 Auto switch mounting positions Auto switch mounting height (mm) D-C7 D-C8 D-H7 D-H7W D-H7F D-H7BAL U D-C7 D-C8 D-C73C D-C80 Auto switch model D-H7W D-H7F D-H7BAL D-H7 D-H7C D-C73C D-C80C D-H7C Bore size (mm) A B A B A B U U 40 22.0 26.0 21.0 25.0 19.5 23.5 35.0 38.0 37.5 50 30.0 18 29.0 17.0 27.5 15.5 40.5 43.5 43.0 26 Series RSDG Auto Switch Internal Circuits Lead wire colors inside
D-Q73 ' D-C731. Parts No. of auio switch Common use to all of D.C7, C8, D-H7 types.
Flow switch Flow range Port size A B C D E F G H I Stop sensor Symbol adjustment type valve valve Nil 61.9 S 61.9 Nil P 95.9 0.5 to 4 127.9 W 95.9 3/8 L/min 132.3 112.9 87.5 102.6 (Max. 141.7 117.9 102.6 Nil 72.5 (symbol 03) (symbol 04) 132.9) S 72.5 Yes P 106.9 W 106.9 Nil 65.9 S 65.9 Nil P 99.9 Remote 3/8 sensor/ 2 to 16 127.9 W 99.9 (symbol 03) L/min (Max. 141.7 117.9 102.6 Integrated
Size Order no. 25 LE-D-6-2 14 32 LE-D-6-3 40 LE-D-6-4 -12- 3. Product Outline 3.1 System construction Refer to the Driver operation manual for system construction. 4.Elictric actuators / Common precautions 4.1 Wiring/Cables Warning 1. Adjustment, installation, inspection, or wiring changes should be conducted after the power supply to this product has been turned off.