SMC Corporation of America
Elite Part Number Search
Search Results "VV2Q32-12-D-00T"

When embedded O-ring Air Machining dimensions for mounting Sealed with O-ring Air Bore size (mm) Stroke A B C D E F G 5 12 8.5 6 4 3.5 M8X1.0 6.5 3 10 20 16.5 14 15 28 24.5 22 5 16 12.5 10 6 3.5 M10X1.0 8.5 3 10 23 19.5 17 15 30 26.5 24 5 17 13.5 10.5 10 3.5 M15X1.5 12 4 10 23.5 20 17 15 30.5 27 24 5 19 14.5 11.5 16 4.5 M22X1.5 19 5 10 25 20.5 17.5 15 31.5 27 24 Note) E and F should be machined

Before restarting the equipment, confirm that measures are taken to prevent sudden action. -12- 2-4.

Power ON12 Power OFF (Auto Power Off function) 12 Toggling the back light 12 Basic operation 13 Measurement mode change 14 Mounting and Setting Speed measurement 16 Installation 16 How to measure 19 Cycle time measurement 20 Installation 20 How to measure 22 Count measurement 23 Installation 23 How to measure 23 Troubleshooting 24 Cross-reference for troubleshooting 24 Error display 25 When

Dimensions 12 Safety Instructions These safety instructions are intended to prevent hazardous situations and/or equipment damage.

Table 3 Thread size Appropriate tightening torque 1/8 3 to 5 1/4 8 to 12 3/8 15 to 20 1/2 20 to 25 (2) If the product is mounted with excessive 2) The outside diameter of polyurethane tubing torque, some sealant will seep out. Remove the excess sealant. swells when internal pressure is applied; therefore, it may not be possible to re-insert used tubing into One-touch fittings.

Dimensions 12 Safety Instructions These safety instructions are intended to prevent hazardous situations and/or equipment damage.

(Refer to the specifications.)Please contact SMC when using a fluid other than compressed air (including vacuum).We do not guarantee against any damage if the product is used outside of the specification range. 12.

(D1) TUH/Standard type 4 2.8 6 4.4 8 5.8 10 7.3 12 8.8 I.D. (D2) O.D. (D1) Tubing I.D. (D2) TUH/High pressure type TU 8 2.5 4 5 6.5 1in = 25.4mm Operating pressure 1.0MPa (at 20C) [145 psi @ 68F] TUH/High Pressure Type Same operating pressure as series TS soft nylon tubing, and a bending radius equivalent to series TU polyurethane tubing.

ASN AQ ASV AK How to Order VCHC F S 1 0 03 06 3 2 AS ASR ASQ Hexagon lock nut Round lock nut J Nil Lock nut option Speed controller Option None Electroless nickel plated Nil N Body size 1 2 3 4 M5 standard 01, 02 standard 03 standard 04 standard Tube size Note) With seal 4 6 8 10 12 04 06 08 10 12 Made to Order Refertopage612for details.

/O.D. mm 5/8 6/9 6.5/10 8/12 8.5/12.5 11/16 167

Multi-counter CEU5mm-m For details, refer to page 12. 1 Counter cable LATH3-m For details, refer to page 11. 2 Controller setup kit LATC-W1 For details, refer to page 12. 3 1

Model: 12 (Top Ported), Connector Type: FW (D-sub Connector, IP67, 25 Pins), Connector Entry Direction: 2 (Lateral), Valve Stations: 12 Stations, P,E Port Entry: B (Both Sides, 2 to 12 Stations), SUP/EXH Block: Internal Pilot, P,E Port Size: ΓΈ12, Mounting: D0 (DIN Rail Mounting w/o DIN Rail)

The display units cannot be changed. selected.) 12 : The unit selection function is not available in Japan due to a new measurement law. : It is fixed to the SI unit "kPa", "MPa". Product failure Replace the product. Key-lock mode is activated. Check if the key-lock function is turned on. Release the key-lock function.

The display units cannot be changed. selected.) 12 : The unit selection function is not available in Japan due to a new measurement law. : It is fixed to the SI unit "kPa", "MPa". Product failure Replace the product. Key-lock mode is activated. Check if the key-lock function is turned on. Release the key-lock function.

D Shows how precisely the pressure can be indicated or set by the digital Pressure switch. When 1 digit = 1 kPa, the pressure is given with an increment Digit (Min. setting unit) of 1 kPa, e.g., 1, 2, 3,, 99, 100. E Energy saving automatic control Indicate that the vacuum pressure during adsorption is monitored and ON and OFF of the ejector is automatically controlled.

c d (4) [][] 10- 2 8 2 6 3 2 () 5 2 2 80802 9 EXH 2 2 ON-OFF 1 1 7 2 2 No. 4 EXH 1 -11- B G 2 ON-OFF () 1 Rc NNPT FG 12MAX.4 -12- Revision history A Sectional view filter deletion of P.5 4-14-1, Sotokanda, Chiyoda-ku, Tokyo 101-0021 JAPAN Tel: + 81 3 5207 8249 Fax: +81 3 5298 5362 URL http://www.smcworld.com Note: Specifications are subject to change without prior notice

Description Material Note 1 Body A PBT 2 Body B PBT 3 Needle PBT 4 Indicator 5 Stopper Stainless-steel 6 Needle guide Brass Electroless nickel Plated 7 Disk seal HNBR 8 Stud Brass Electroless nickel Plated 9 O-ring NBR 10 O-ring NBR 11 O-ring NBR 12 O-ring 13 Seal NBR 14 Gasket NBR/Stainless-steel 15 O-ring NBR Meter-in type only 12 - Doc.no.DOC1019547 Seal method/Sealant For R,NPT Seal method

Magnet: D (Built-in), Mounting: B [Through Hole (Standard; 12 through 63 Bore)], Bore Size: 12mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 25mm, Body Option: C (Rubber Bumper), Auto Switch Groove: None (for 12-25 Bore w/o Magnet), Auto Switch: No Switch, Lead Wire or Prewired Connector: M (1m)

Magnet: D (Built-in), Mounting: B [Through Hole (Standard; 12 through 63 Bore)], Bore Size: 12mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 30mm, Body Option: C (Rubber Bumper), Auto Switch Groove: None (for 12-25 Bore w/o Magnet), Auto Switch: No Switch, Lead Wire or Prewired Connector: M (1m)

Magnet: D (Built-in), Mounting: B [Through Hole (Standard; 12 through 63 Bore)], Bore Size: 12mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 5mm, Body Option: C (Rubber Bumper), Auto Switch Groove: None (for 12-25 Bore w/o Magnet), Auto Switch: No Switch, Lead Wire or Prewired Connector: M (1m)