SMC Corporation of America
Elite Part Number Search
Search Results "JCDQA20-5"

Particle diameter Adsorption surface size A B C Standard (0.3) 1 2 3 4 5 6 50 x 50 mm 100 x 100 mm 150 x 150 mm 200 x 200 mm 250 x 250 mm 300 x 300 mm 0.2 0.4 When particle diameter and port position are both standard, neither of them are specified.

Option 1 W Nil DIN Rail Mounting Bracket (Order Separately) With lead wire with connector (2 m) Connector cover (Silicone rubber) ZS 33 R With lead wire with connector (2 m) ZS-33-F S Stations ZS-33-D ZS-33-D S 1 2 3 4 5 1 station 2 stations 3 stations 4 stations 5 stations IN IN N Note) If an accessory is required, order separately using ZS part numbers.

Series 10-VQD1000 [Option] 4 Port Direct Operated Poppet Solenoid Valve How to Order Valve Clean series Valve option Nil Standard (2 W) V Vacuum (2 W) U For large flow (3.2 W) W For large flow, Vacuum (3.2 W) Energy saving type Rated voltage 5 24 VDC 6 12 VDC Body type 2 Body ported (Single unit) 3 Body ported (Manifold) 5 Base mounted 10 V Q D 1 1 5 1 U 5 L M5 Electrical entry CE-compliant

Model Cushion Bore size (mm) 6 10 16 Action Standard stroke (mm) Auto switch mounting Port size Lubrication Model Rubber Air 10-/21-CDU6 10-/21-CDU10 10-/21-CDU16 Relief type Vacuum suction type 5, 10, 15, 20, 25, 30 10-/21-CDU20 20 5, 10, 15, 20, 25, 30, 40, 50 10-/21-CDU25 25 Non-lube Double acting Single rod M5 x 0.8 6 10 16 11-/22-CDU6 11-/22-CDU10 11-/22-CDU16 5, 10, 15, 20, 25, 30

(Full span) or less Hysteresis Pressure switch with digital display and self-contained solid state sensor 3% F.S. (5 to 40C), 5% F.S. (5 to 60C) Accuracy AF 12 to 24 VDC (Ripple 10% or less) Voltage Minimum allowable pressure indicator on digital display AR Open collector 30 V, 80 mA or less Output Light turns ON when pressure drops below the set minimum.

(at 25C water) Temperature characteristics 5% F.S. (0 to 50C, based on 25C) Pulse output, N channel, open drain, output for monitor unit PF2D 300/301 (Specifications: Maximum load current of 10 mA; Maximum applied voltage of 30 V) Pulse output Output Voltage output Note 5) 1 to 5 V Accuracy: 2% F.S., Min. load impedance: 100 k (Output impedance: 1 k) Analog specifications Current output Note

1 Made to Order Nil 1 3 5 Without cable 1.5 Nil D Screw mounting DIN rail mounting1 Nil X5 Standard product With magnet/switch rail 3 1 Only available for the controller types 6N and 6P 2 DIN rail is not included. Order it separately. 5 When Without controller is selected for controller types, I/O cable length cannot be selected.

Model HRS200-Am-46-mS Cooling method Air-cooled refrigeration Refrigerant R410A (HFC) Refrigerant charge kg 1.65 Control method PID control Ambient temperature/Altitude1, 7 C Temperature: 5 to 45, Altitude: less than 3000 m Circulating uid1, 2 Tap water, 15% Ethylene glycol aqueous solution, Deionized water Set temperature range1 C 5 to 35 Cooling capacity3, 7 kW 20.5 Heating capacity4 kW

/min 612 V V gal/min 712 V gal/min Port size Symbol Port size Applicable model LFE1 LFE2 LFE3 3 3/8 V 4 1/2 V 6 3/4 V 8 1 V 1 Options 4, 5, 6, and 7, which are not in SI units, are not for use in Japan due to the New Measurement Law. 2 Options 4, 5, 6, and 7 cannot be selected when the output specication is J or K.

N.O. 125 VAC 15 15 4 2 10 10 4 2 250 VAC 15 15 3 1.5 10 10 3 1.5 8 VDC 15 15 3 1.5 15 15 5 2.5 15 15 3 1.5 10 10 5 2.5 14 VDC 30 VDC 3 6 6 1.5 5 5 5 2.5 125 VDC 0.5 0.5 0.3 0.3 0.05 0.05 0.05 0.05 250 VDC 0.25 0.25 0.2 0.2 0.03 0.03 0.03 0.03 16-12-6

Wiring (Output) Load voltage Auto switch model Lead wire length [m]2 Pre-wired connector Applicable load Electrical entry direction 0.5 (Nil) 1 (M) 3 (L) 5 (Z) DC AC Perpendicular In-line Indicator light Type Special function Electrical entry M9NV M9N V V V v v IC circuit 3-wire (NPN) 5 V 12 V Solid state auto switch 3-wire (PNP) M9PV M9P V V V v v 2-wire 12 V M9BV M9B V V V v v 3-wire

2-wire 3-wire (NPN) 3-wire (PNP) 2-wire 5V, 12 V 12 V 5V, 12 V 12 V 5 V, 12 V 12 V IC circuit Solid state switch Reed switch IC circuit Relay, PLC Diagnosis (2-color indication) 24 V Grommet Yes IC circuit Water resistant (2-color indication) M9PAV M9BAV A96 A93 A90 A96V A93V A90V IC circuit IC circuit 5 V 12 V Yes Grommet 100 V 3-wire (NPN equivalent) Relay, PLC 2-wire 24 V No 5 V

4 1 1 1 2 1 4 1 2 32 5 Nil: Non-locking push type 40 6 Valve size 5 to 7 50 7 Note) Air operated only Note) Semi-standard Electrical entry/With light/surge voltage suppressor Valve size 1 to 4 Valve size 5 to 7 Electrical entry Symbol Table (1) Applicable Fluids VNAA (Valve material: NBR seal) VNAB (Valve material: FKM seal) VNAC (Valve material: EPR seal) GS Grommet with surge voltage suppressor

Compact Vacuum Ejector Series ZA How to Order Ejector Unit ZA1 1 07 K1 P1 5 L 0 1 Nozzle nominal size Vacuum (V) port 05 07 0.5 0.7 Applicable tubing O.D. Part no. KJS23-M5 KJS04-M5 KJL23-M5 KJL04-M5 Symbol 1 2 4 5 3.2 (Straight) 4 (Straight) 3.2 (Elbow) 4 (Elbow) Solenoid valve combination (Refer to Table (1).)

Recommended flow rate Note) (l/min (ANR)) Mass (g) Internal capacity (cm3) 1.7 ZA Model IN side, OUT side 2 3.2 4 4 6 6 8 1/8" 5/32" 5/32" 1/4" 1/4" 5/16" ZFC050-02 ZFC050-23 ZFC050-04 ZFC100-04 ZFC100-06 ZFC200-06 ZFC200-08 ZFC051-01 ZFC051-03 ZFC101-03 ZFC101-07 ZFC201-07 ZFC201-09 2 7 10 10 20 30 50 7 10 10 20 30 50 4.9 ZX 1.7 4.3 IN/OUT straight piping Metric size ZR Easy installation

flow rate [L/min (ANR)] Suction flow rate [L/min (ANR)] Note 1) Air consumption [L/min (ANR)] Discharge flow rate [L/min (ANR)] 4,500 3,000 ---6 ---6 Discharge flow rate 4,000 Discharge flow rate Vacuum pressure [kPa] Vacuum pressure [kPa] Vacuum pressure Vacuum pressure 2,500 ---5 ---5 3,500 3,000 2,000 ---4 ---4 Suction flow rate 2,500 Suction flow rate 1,500 ---3 ---3 2,000 1,500 1,000