Appendix . 8-1 8.1 Specification . 8-1 8.1.1 Product specification . 8-1 8.1.2 Refrigerant with GWP reference . 8-8 8.1.3 Communication specification. 8-9 8.1.4 Alarm signal selection . 8-11 8.2 Outer Dimensions . 8-12 8.3 Flow Chart . 8-13 8.3.1 HRZD020-WS-WS, HRZD020-W1S-W1S, HRZD020-W1S-WS, HRZD020-WS-W1S . 8-13 8.4 Offset Function . 8-14 HRZD Series TOC--3 HRX-OM-M005 Table of Contents
Configuration One thermo-chiller for one master. 2 2 R D R D 3 3 S D S D 5 5 S G S G Master This product Do not connect any wire to other PIN numbers. Fig. 3-8 Connection of RS-232C 3.3 Installation HRR Series 3-18 HRX-OM-W002 Chapter 3 Transport and Setting Up 3.4 Piping Piping port size Connect piping firmly.
Connector C Actuator side (Terminal no.) 1 2 5 6 (8) (14) (18) A1 B1 (13.5) (17.7) (17.7) Cable length (L) [m] 1 3 5 8 A B C 1 2 1.5 3 5 8 A6 B6 (30.7) Connector A 15 16 (14.7) Connector D L (11) (10) LE-CP/Cable length: 8 m, 10 m, 15 m, 20 m ( Produced upon receipt of order) 8 A B C Controller side 10 (14.2) Connector C (Terminal no.) 1 2 5 6 Step Motor (Servo/24 VDC) 15 (5.5) (6.3) Actuator
Option J: With drain guide Bracket (Option) 1/4B female thread T: With element service indicator Maintenance space HA Drain AT ID AMG AFF Element service indicator Dimensions with mounting bracket Model Port size (Nominal size B) A B C D E F G H 10 10 10 10 10 10 10 10 10 I 56 66 66 80 80 90 90 100 150 J 15 20 17 22 19 25 21 30 40 K 5 8 8 8 8 10 10 10 15 L 9 12 12 14 14 14 14 16 20 M 5.5
9 Rod seal NBR Basic (B) CM2QB Bore size Stroke (mm) Stroke range 1 to 300 1 to 300 1 to 300 1 to 300 S 65 65 67 91 N 15 15 15 21.5 Bore A 18 22 22 24 B2 26 32 32 41 D 8 10 12 14 H2 8 8 8 10 I 28 33.5 37.5 46.5 ZZ 119 123 125 157 NA 24 30 34.5 42.5 AL 15.5 19.5 19.5 21 E F 13 13 13 16 K 5 5.5 5.5 7 NN M20 X 1.5 M26 X 1.5 M26 X 1.5 M32 X 2 B1 13 17 17 22 G 8 8 8 11 MM M8 X 1.25 P 1/8 1/8 1
Control, Inspection and Cleaning . 8-1 8.1 Control of Circulating Fluid Quality . 8-1 8.2 Inspection and Cleaning . 8-2 8.2.1 Daily check . 8-2 8.2.2 Monthly check . 8-3 8.2.3 Inspection every 3 months . 8-4 8.2.4 Inspection every 6 months . 8-5 8.2.5 Inspection for winter season . 8-6 8.3 Consumables . 8-6 8.4 Stop for a Long Time . 8-7 8.4.1 Discharge of the circulating fluid and facility
Appendix . 8-1 8.1 Specification . 8-1 8.1.1 System specification . 8-1 8.1.2 Communication specification. 8-4 8.1.3 Alarm signal selection . 8-6 8.2 Outer Dimensions . 8-7 8.3 Flow Chart . 8-8 8.3.1 Part 1 . 8-8 8.3.2 Part 2 . 8-8 8.4 Offset Function . 8-9 8.4.1 Example of offset function . 8-10 8.5 BAND/READY function . 8-12 8.6 Anchor Bolt Mounting Position . 8-13 8.7 Compliance . 8-14
port 1/8, 1/4 (Rc, NPT, G) 2 x P Port size 2 x P Port size F E F E D D C B C B Port size: Size 14 A A ( 52) ( 52) (20) (20) Silencer (Option) Silencer (Option) Pilot port 1/8, 1/4 (Rc, NPT, G) Pilot port 1/8, 1/4 (Rc, NPT, G) Exhaust port 3/8 Exhaust port 3/8 2 x P Port size 2 x P Port size F E F E G G D C B D C B 20 20 Dimensions [mm] Model Port size P A B C D E F G JSXFAF-06 3/4 74 55.5
Then, the data which is written in avobe (2) are sent to the controller(LEC). (5)When the sending to the controller(LEC) is completed, Sending completed(RWrn+8[bit 8]) is changed from 0 to 1. (6)Write 0 in RWwn [bit8-F]. Then, Sending completed (RWrn+8[bit 8]) changes from 1 to 0. 36 - 12.
2 / / / 2 n_n / LoC() 4 UnL LoC 4 LoC UnL 5F.S.(2.5F.S.) 1 12341 2 2 2 -27No.PS-OMH0005CN-D (2030 ) -28No.PS-OMH0005CN-D PSE200 ( ) 1 ON ON OFF Yes No 2 OFF ON 1 OFF 3 4 5 OFF 6 -29No.PS-OMH0005CN-D 7 Yes No 8 8 9 10 11 12 13 14 15 16 -30No.PS-OMH0005CN-D No.
Option Bracket J: With drain guide (Option) female thread T: With element service indicatior Maintenance space Drain Element service indicator Dimensions with mounting bracket Model Port size (Nominal size B) A B C D E F G H 10 10 10 10 10 10 10 10 10 I 56 66 66 80 80 90 90 100 150 J 15 20 17 22 19 25 21 30 40 K 5 8 8 8 8 10 10 10 15 L 9 12 12 14 14 14 14 16 20 M 5.5 6 6 7 7 9 9 9 11 N 35
E R E X H A U S T C L E A N E R S E R I E S (N)AMC 0 (N)AMC Japanese N North American O P T I O N B Bracket D Threaded Drain Port (Female) B O D Y S I Z E P O R T S I Z E 2 1/4 3 3/8 5 3/4 6 1 8 1 1/2 9 2 02 1/4 03 3/8 04 1/2 06 3/4 10 1 14 1 1/2 20 2 T H R E A D T H R E A D 1 Male 2 Female (Only NAMC220, 320, 520 Special Order Only) R(PT)* Remove (N) when ordering N NPT FOR FURTHER TECHNICAL
PLC (3) PP (8) (4) The OUT0 (INP) output turns OFF. NP (5) The "BUSY" output turns ON. OUT0 (4)(6)(9)(11) (INP) Output (6)When the traveling is completed, "OUT0" (INP) output turns ON. (5)(7)(10)(12) BUSY (7) The BUSY output turns OFF. Traveling to target position 1 is completed. (8) Enter pulse input signals.
C A , C D A F A 2 C A , C D A F A 2 C A , C D A F A 2 C A , C D A F A 2 C A F A 2 C A F A 2 C A F A 2 C A t e n n o B C D A r e b m a h C F A 2 C A , C D A F A 2 C A , C D A F A 2 C A , C D A F A 2 C A , C D A F A 2 C A F A 2 C A F A 2 C A F A 2 C A e d i u g e v l a V F A 2 C A , C D Z F A 2 C A , C D Z F A 2 C A , C D Z F A 2 C A , C D Z F A 2 C A F A 2 C A F A 2 C A F A 2 C A ) f g k (
h Grommet terminal i Conduit terminal j DIN terminal a Model b d e f VEX5510 VEX5511 19 130 110 9 12 2.3 204 204.5 222 221.5 32 VEX5710 VEX5711 136 120 9 20 2.3 221 221.5 239.5 239 VEX5910/5911 Bracket (Option) Pressure gauge (Option) Grommet terminal (E) DIN terminal (D) Applicable O.D. 6 to 8 Conduit terminal (T) 1/4 (P2) 1/4 (P1) Refer to page 2449.
Symbol -X80, -X81 Main Value Double Acting Type 1 A N 06 5 1 4 VP31 1 D Z X81 Body size CE marking Nil Q None CE-compliant 4 6 8 1/2 1 1 1/2 3/8 1/2 3/4 1 1 1/4 1 1/2 2 Port size (IN, OUT port) Thread type Symbol VP3145 VP3165 VP3185 Port size Nil F N T D/DO/DZ/DU only Rc G NPT NPTF 03 04 06 10 12 14 20 Type of actuation X80 X81 Double solenoid Single solenoid External pilot Passage, Type
JXC-OMT0034CN (GW)(CC-Link) / LEC-GMJ2 1. . 4 2. . 6 2.1 . 6 2.2 . 6 2.3 . 7 2.4 () . 8 (1) . 8 (2). 8 (3)(LEC) . 8 (4). 8 (5) . 8 (6) . 9 (7) . 9 3. . 10 3.1 . 10 3.2 . 12 3.3 . 13 (1)(LECGMJ2) . 13 (2)DIN (LECGMJ2D) . 13 3.4 . 14 (1) . 14 (2) . 14 4. . 15 4.1 (STATION NO.,B RATE) . 15 4.2 (CN2SW) . 16 4.3 (LEC) . 17 5. . 19 5.1 CN4 . 19 5.2 CN3 . 19 5.3 CN1CONT . 19 5.4 CN2PC
size Port size Rc Option Applicable pilot valve (4) Mounting Port 1(P), 2(A) Port 3(R) 00 M5 00 M5 01 00 01 02 00 02 03 04 M5 01 02 02 03 04 04 06 10 10 12 14 20 Without sub-plate M5 Without sub-plate M5 D B 1 8 Without sub-plate Symbol Base mounted 2 1 8 1 4 Internal pilot VY1D0 (5) Without sub-plate 1 4 4 3 8 1 2 A (3) (3) M5 3(R) 1 8 2(A) 1(P) 1 (3) (3) 1 4 1 4 3 3 8 External pilot 1
Model Rc1/8 Rc1/8 Rc1/8 ZH05DA ZH07DA ZH10DA NPT1/8 NPT1/8 NPT1/8 ZH05DA ZH07DA ZH10DA Screw-in Screw-in EXH. SUP. Rc1/8 Rc1/4 Rc1/4 ZH13DA NPT1/8 NPT1/4 NPT1/4 ZH13DA Rc1/4 Rc3/8 Rc3/8 ZH15DA NPT1/4 NPT3/8 NPT3/8 ZH15DA Rc3/8 Rc3/8 Rc3/8 ZH18DA NPT3/8 NPT3/8 NPT3/8 ZH18DA Rc3/8 Rc1/2 Rc1/2 ZH20DA NPT3/8 NPT1/2 NPT1/2 ZH20DA Screw-in VAC. Silencer and standard bracket are available.