70 78 100 125 138 155 8 8 12 12 16 16 16 50 57 64 80 100 112 132 34 36 46 58 61 75 95 60 70 78 100 125 138 155 5.5 6.6 9 9 9 12 14 5.5 6.6 9 9 9 12 14 44 48 60 74 78 100 120 44 48 60 74 78 100 120 114 136 167 190 211 237 264 Double clevis style: (D) Clevis pins and cotter pins are included.
Dimensions . 46 47 48 50 52 52 53 54 54 55 55 56 57 58 60 60 60 61 62 63 65 65 65 66 66 67 67 68 69 69 70 70 71 72 73 75 75 75 77 77 78 78 78 79 80 82 84 84 84 85 86 87 87 88 89 90 Series AS * 2 * 0-D Speed Controller Adjustable by Flat Head Screwdriver: Standard Type Elbow Type \(Metal Body\) . Specifications. How to Order . Construction. Dimensions .
override Rated voltage Nil Push type 1 2 3 100 VAC, 50/60 Hz 200 VAC, 50/60 Hz B Locking type (Slotted) C Locking type (Manual) 110 to 120 VAC, 50/60 Hz 4 Surge voltage suppressor Option 220 VAC, 50/60 Hz Indicator light 24 VDC 12 VDC 5 6 Light/Surge voltage suppressor E EZ Nil None 7 240 VAC, 50/60 Hz With light/surge voltage suppressor (Type E, T, D, or Y only) 9 Other Z Option S With
per minute 1 60 = x x Reference life cycles Cycles per minute 1 8 (daily operating time) Service life 1 60 = 1 8 50,000,000 50 x x 2083 days = 27 Process Pump Common Precautions 5 Be sure to read before handling.
Since a large quantity of liquid will be pumped out, use a suitable throttle in the discharge port if problems occur. 17-5-163 24 Series PB Performance Curves: Built-in Solenoid Valve Type/Air Operated Type Cycle 1 Hz Cycle 5 Hz Cycle 10 Hz 70 70 70 60 60 60 Total lifting range (m) Total lifting range (m) Total lifting range (m) 50 50 50 40 40 40 SUP = 0.7 MPa SUP = 0.7 MPa SUP = 0.7 MPa
Rated voltage Electrical entry 2 200 VAC 50/60 Hz 1 100 VAC 50/60 Hz G Grommet C Conduit 3 110 VAC 50/60 Hz D DIN terminal 4 220 VAC 50/60 Hz T Conduit terminal 5 24 VDC Refer to the table (1) given below for availability. 6 12 VDC 7 240 VAC 50/60 Hz 8 48 VAC 50/60 Hz 9 Other (Contact us for inquiry) Refer to the table (1) given below for availability.
T NPTF Coil rated Electrical entry 3 8 G F 1 100 VAC, 50/60 Hz Grommet Nil T Conduit terminal Standard 4 1 2 Option 2 200 VAC, 50/60 Hz Port size Manual override P None Nil Option WTB Dripproof conduit terminal 3 110 VAC, 50/60 Hz 1 4 Rc 3 8 Rc 1 2 Rc 3 4 Rc 02 03 04 06 TZ Conduit terminal w/ surge voltage suppressor 4 220 VAC, 50/60 Hz How to Calculate the Flow Rate 5 24 VDC 9 Other TL
With light/surge voltage suppressor (Non-polar type) : SY100-30-A U Without lead wire (with connector and 2 of sockets only) Lead wire length Nil 6 10 15 20 25 30 50 300 mm 600 mm 1000 mm 1500 mm 2000 mm 2500 mm 3000 mm 5000 mm Rated voltage 5 6 V S R 1 2 Electrical entry 24 VDC 12 VDC 6 VDC 5 VDC 3 VDC 100 VAC 50/60 Hz 200 VAC 50/60 Hz 110 VAC 50/60 Hz [115 VAC 50/60 Hz] G H L LN LO M MN
5 Port Solenoid Valve VQC1000/2000 Series Metal Seal Rubber Seal Connector Type Manifold IP67 enclosure compatible Power saving Power saving SV SYJ Standard: 0.4 W Standard: 0.4 W SZ RoHS (Reduced by 60% compared to current model) (Reduced by 60% compared to current model) VF VP4 High-pressure (1 MPa, Metal seal): 0.95 W High-pressure (1 MPa, Metal seal): 0.95 W VQ 1/2 VQ 4/5 VQC 1/2 VQC
1 2 100 VAC, Hz 200 VAC, Hz 50 60 50 60 3 4 5 6 110 VAC, Hz 220 VAC, Hz 24 VDC 12 VDC 7 240 VAC, Hz 50 60 Port size 50 60 Note 1) CE-compliant: Electrical entry is applicable only for the DIN terminal.
Hz) 200 VAC (50/60 Hz) 110 VAC (50/60 Hz) 220 VAC (50/60 Hz) 24 VDC 12 VDC Other 1 2 3 4 5 6 9 Note) Option Note) Except large flow type.
) 54.5 40 55.0 50 Set point 60 55.5 70 56.0 80 56.5 90 100 0 20 40 60 80 100 120 57.0 100 95 90 85 80 75 70 65 60 Flow rate (l/min (ANR)) VAC side pressure (kPa) IRV3000 IRV3000 0 53.0 10 53.5 20 54.0 SET side pressure (kPa) 30 Set pressure (kPa) 54.5 40 55.0 50 Set point 60 55.5 70 56.0 80 56.5 90 57.0 100 95 90 85 80 75 70 65 60 100 0 20 40 60 80 100 120 140 160 VAC side pressure (kPa)
Refer to page 16-11-10. 16-11-28 25 Series PF2W Digital Flow Switch, High Temperature Fluid Type For Water Dimensions: Integrated Display Type for Water Internal circuit and wiring example to are terminal numbers. 74 120 Brown 1.6 23 60 Load 1 OUT1 Main circuit 4 Load Black OUT2 2 ZSE ISE 12 to 24 VDC FLOW SWITCH + U P White 3 SET 60 50 34 Blue PSE OUT2 OUT1 PF2W7T--27(-M) DOWN FOR WATER
Use 2 port valve VNH33. 4.2-33 VNH Dimensions Dimensions (mm) Model Main port 2 port 3 port Pilot port H I A C B D E F G 3 8 3 8 Rc(PT) 1 8 2-Rc(PT) 2-Rc 3-Rc(PT) 3-Rc 50 60 79 90 77 95.5 111 119 60 80 100 115 235.5 265 300 319.5 60 77 96 113 46 60 76 85 34 40 50 60 24 36 41 50 135 164.5 200 219 VNH1 -10A VNH2 -15A VNH3 -20A VNH4 -25A A B A B A B A B 1 2 3-Rc 3 4 3-Rc1 Rc1 4 Rc1 4 Rc1 8 1
Hz) 200 VAC (50/60 Hz) 110 VAC (50/60 Hz) 220 VAC (50/60 Hz) 24 VDC 12 VDC Other 1 2 3 4 5 6 9 Note) Option Note) Except large flow type.
Hz) 200 VAC (50/60 Hz) 110 VAC (50/60 Hz) 220 VAC (50/60 Hz) 24 VDC 12 VDC Other 1 2 3 4 5 6 9 Note) Option Note) Except large flow type.
[Hz] PB34 VRF12B 1 60 [Hz] PB35 VRF13B 1 0.15 PB36 VRF14B 1 0.15 PB56 VRF21B 2 30 [Hz] PB57 VRF22B 2 30 [Hz] PB58 VRF23B 2 0.05 PB59 VRF24B 2 0.05 7 18 7.
(30 10-3) = 2000 [pulses/s) Acceleration time: 60 1500 = 40 [ms] Deceleration time: 60 1000 = 60 [ms] [Calculation example: Target position 2] Travel distance: 6 (30 10-6) = 200 [pulses] (in the reverse direction) Travel speed: 60 (30 10-3) = 2000 [pulses/s] Acceleration time: 60 1500 = 40 [ms] Deceleration time: 60 1000 = 60 [ms] 61 - Step Data setting example Thrust Load mass
It is already built-in to the rectifier circuit. 2 200 VAC 50/60 Hz 110 VAC 50/60 Hz [115 VAC 50/60 Hz] 3 Electrical entry 4 220 VAC 50/60 Hz [230 VAC 50/60 Hz] D With connector DIN terminal DO Without connector DC specifications of type D and DO is only available with 12 and 24 VDC. Power saving circuit is not available in the case of D or DO type.
It is already built-in to the rectifier circuit. 1 2 3 4 7 300 mm 500 mm 1000 mm 2000 mm 5000 mm 110 VAC 50/60 Hz [115 VAC 50/60 Hz] 3 4 220 VAC 50/60 Hz [230 VAC 50/60 Hz] Electrical entry D With connector DIN terminal DC specifications of type D and DO is only available with 12 and 24 VDC. Power saving circuit is not available in the case of D or DO type.