AL Standard Specifications AL30 AL40 AL60 AL10 AL20 AL40-06 AL50 Model 1/4, 3/8 Port size 1/4, 3/8, 1/2 1 M5 x 0.8 1/8, 1/4 3/4 3/4, 1 Fluid Air Proof pressure 1.5 MPa Maximum operating pressure 1.0 MPa 1/4: 30 3/8: 40 1/2: 50 135 Note) 1/4: 30 3/8: 40 Minimum dripping flow rate (/min (ANR)) 220 4 15 50 190 Oil capacity (cm3) 55 135 7 25 135 135 Recommended lubricant Class 1 turbine oil (
Membrane Air Dryers 361 405 428 468 548 618 83 187 53 113 212 54 1/4 73 140 40 Port size L B A Port size L A B C 70 91 3/8 1/2 3/8 IN Port size: 1/4 OUT Port size: 1/4 IDG30, 30L IDG50, 50L IDG60 IDG75, 100 IDG60L, 60S IDG75L, 75S IDG100L, 100S Model Model (67) (46) (26) IDG3, 5 IDG10 IDG20 Width across flats 17 Width across flats 14 Width across flats 14 Purge air outlet for dehumidification
CXSJ10 / CXSJ10 11122122Note 2) D B Note 3) (mm) D-M9 34 (35.5) 3.5 (2) 24 (25.5) 6.5 (8) D-A93 30 (31.5) 25.5 (27) 5 (6.5) Symbol A B C D Note 1) The above mentioned values are indicated as a guide for auto switch mounting positions for stroke end detection. When actually mounting an auto switch, adjust the position after confirming the operating state of the auto switch.
Note 4) The values in the table are not warranted, but the measured values. 393 Soft Fluoropolymer Tubing Inch Size Series TID Model/Specifications Inch size Model Size TID01 TID05 3/16" 4.75 TID07 1/4" 6.35 TID11 3/8" 9.53 TID13 1/2" 12.7 inch mm 1/8" 3.18 Tubing O.D. 0.124" (1/8") 0.156" (5/32") 0.25" (1/4") 0.374" (3/8") 0.086" inch Tubing I.D. mm 8 m 16 m 2.18 3.15 3.95 6.33 9.5
Operating Note 3) 2-position 8-6:5, 8-8:6, 8-10:5 8-6:20, 8-8:15, 8-10:10 frequency cycle/sec. 3-position 8-6:3, 8-8:3, 8-10:2 8-6:10, 8-8:10, 8-10:20 Lubrication Not Required Manual override Non-locking push type Protection structure Dust Proof Coil rated voltage 100VAC, 110VAC, 200VAC, 220VAC, 24VDC Allowable voltage range % -15~ +10% of rated voltage Coil insulation Class B or equivalent
Air supply port (AIR SUP) 5 port solenoid valve P1 P2 Discharge port (FLUID OUT) Pump chamber A Pump chamber B Check valve Actuating chamber B Suction port (FLUID IN) Diaphragm A Diaphragm B Actuating chamber A Actuating chamber A Actuating chamber B Actuating chamber A Actuating chamber B Discharge port Discharge port Pump chamber B Pump chamber B Pump chamber A Pump chamber A Suction port
Stroke range Part no.: CLQB40-47D-B 3 mm spacer is installed in standard cylinder CLQB40-50D-B. B dimension is 79.5 mm. Example Note) 40 to 100 bumper spacers with intermediate strokes can be manufactured in 5 mm increments from 55 to 95 mm. D-X Individual -X 817
(see drawing on the left) Product Groove Bottom of the body Finger Bracket A Mounting of bracket B Fix the bracket B with the set screw (2 pcs.) included in the package. Refer to the table below for the 2) tightening torque. Bracket B Model No. Tools Tightening torque AMK50 Phillips screwdriver(+) 1.50.2 N m AMK60 Set screw (2 pcs.) -11- 8. Troubleshooting Refer to [9.
Standard M5 x 0.8 M5 x 0.8 M5 x 0.8 M5 x 0.8 10-V14: 13(27) 10-V14A: 16(30) 10-V14: 12(26) 10-V14A: 15(29) Large flow capacity Standard 10-V124A Note 1) Large flow capacity Valve model 12 [32 Note 3)] Flow characteristics 23 [21 Note 3)] b b Cv Cv C[dm3/(sbar)] 0.054 0.099 0.037 0.076 C[dm3/(sbar)] 0.037 0.076 0.054 0.099 10-V114 10-V114A 10-V124 Note 1) 0.008 0.016 0.015 0.024 0.015 0.024
Drain Series AFF Size Series AM, AMD, AMH Size 150 Series AFF Size Series AM, AMD, AMG, AMH Size Port size A B Connection A B 239 252 258 284 290 2B 80 1/4 , 3/8 1/8 , 1/4 , 3/8 450 550 650 850 256 260 300 300 349 380 496.5 11B 22B 37B 75B 240 3/4B, FF , 10K 1B, FF , 10K 1 B, FF , 10K 2B, FF , 10K 80 250 4B 1/2 1 2 3/8 , 1/2 3/4 1/2 , 3/4 1 3/4 , 1 1 , 1 1 , 2 80 8B 350 80 305 312 339 80
Suffix R:Bracket, Name plate, Mounting on the opposite side Note1) Accessories Port size 01: 1/8 Note4) NIL: None B: Bracket (P36201023) G: Pressure gauge Note2) Note3) Thread type when Rc and G. Thread type when NPT.
Output data Offset MSB LSB MSB LSB (Word) 15 8 7 0 0 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 -38No.EX-OMP0013-E Dimensions If a fieldwireable connector is used for the power supply connection, and the SI unit is installed directly to a valve manifold, the cable connectors outer diameter should be 16 mm or less.
Connection thread size NPT , NPT, R NPT, R NPT, R NPT, R Standard torque (Nm) 7 to 9 12 to 14 22 to 24 28 to 30 Connecting Female Thread: Rc, NPT, NPTF 1 16 1 8 Approx. spanner tightening angle after tightened by hand deg Standard torque (Nm) Nominal size of uni thread 1 4 3 8 1 2 1 8 1 4 3 8 1 2 30 to 60 30 to 60 15 to 45 15 to 30 5 to 7 11 to 13 14 to 16 20 to 22 Courtesy of Steven Engineering
It cannot be used if a water hammer or pulsation pressure is applied to the fluid. 8. In order to prevent a malfunction or diaphragm damage caused by debris or cutting chips in the fluid, install a filter with approximately 100 mesh on the inlet side of a flow switch. C (COM) A (N.O.) Color of lead wire Black Symbol Contact C Z I SE3 Common A White Normally Open B (N.C.)
50 or more 12 168 or more 132 or more 88 or more 60 or more 8 - 2.
8.7 120 X T V 1/4 1/4 1/8 40 P 46 46 38 PP 70 50 M12 x 1.75 M10 x 1.5 M8 x 1.25 N H GA C M6 M6 M5 18.5 KA KB 100 63 30, 50, 75, 100 40 78 73 58 66.5 61.5 48.5 4 4 3.5 8 100 90 120 160 1/8 1/8 1/8 8 200 160 20 20 11.5 11.5 9.5 846 Guide Table 10-MGF Specific Product Precautions Be sure to read this before handling.
Name Alarm flag 1 Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Name Alarm flag 2 Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Name Alarm flag 3 Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Name Alarm flag 4 Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Bit Name Explanation 0 Low level in tank 1 High circulating fluid discharge temp. 2 Circulating fluid discharge temp. rise 3 Circulating fluid discharge
Name Alarm flag 1 Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Name Alarm flag 2 Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Name Alarm flag 3 Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Name Alarm flag 4 Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Bit Name Explanation 0 Low level in tank 1 High circulating fluid discharge temp. 2 Circulating fluid discharge temp. rise 3 Circulating fluid discharge
P P Standard specifications Optional specifications Set pressure max. 0.5MPa 3 P P Approx. 133 Set pressure max. 0.9MPa 5 P P Connection Rc(PT) 1/4 02 P P eL-bracket rT-bracket Connection Rc(PT) 3/8 03 P P Connection Rc(PT) 1/2 04 P Bracket B p p Accessories 178 Bracket C p p Connection NPT1/4 N02 p p qAF3000 wAFM3000 eITV2000 Connection NPT3/8 N03 p p Connection NPT1/2 N04 p Connection