SMC Corporation of America
Elite Part Number Search
Search Results "ISE10-M5-C-GD"

Piping: ø4, ø5/32" One-touch Fitting, Straight Type, Output: PNP Open Collector 2 Outputs, Display Unit: w/Unit Display Switching Function, Lead Wire: Lead Wire w/Connector & Connector Cover, Bracket/Panel Mount Adapter: Panel Mount Adapter+Front Protection Cover, Operating Manual/Certificate: Operating Manual, Booklet, Made to Order: M12 4-pin Prewired Connector

Piping: R 1/8, w/M5 Female, Output: NPN Open Collector 2 Outputs, Display Unit: w/Unit Display Switching Function, Lead Wire: Lead Wire w/Connector & Connector Cover, Bracket/Panel Mount Adapter: Panel Mount Adapter+Front Protection Cover, Operating Manual/Certificate: Operating Manual, Booklet, Made to Order: M12 4-pin Prewired Connector

Piping: ø4, ø5/32" One-touch Fitting, Elbow Type, Output: PNP Open Collector 2 Outputs, Display Unit: w/Unit Display Switching Function, Lead Wire: Lead Wire w/Connector & Connector Cover, Bracket/Panel Mount Adapter: Panel Mount Adapter+Front Protection Cover, Operating Manual/Certificate: Operating Manual, Booklet, Made to Order: M12 4-pin Prewired Connector

Piping: ø6 One-touch Fitting, Elbow Type, Output: PNP Open Collector 2 Outputs, Display Unit: w/Unit Display Switching Function, Lead Wire: Lead Wire w/Connector & Connector Cover, Bracket/Panel Mount Adapter: Panel Mount Adapter+Front Protection Cover, Operating Manual/Certificate: Operating Manual, Booklet, Made to Order: M12 4-pin Prewired Connector

Piping: NPT 1/8, M5 Female, Output: PNP Open Collector 2 Outputs, Display Unit: w/Unit Display Switching Function, Lead Wire: Lead Wire w/Connector & Connector Cover, Bracket/Panel Mount Adapter: Panel Mount Adapter+Front Protection Cover, Operating Manual/Certificate: Operating Manual, Booklet, Made to Order: M12 4-pin Prewired Connector

Body Size: 20, Thread: Rc (Rc: for Sizes 20, 25, 30, 40; M5: for Size 10), Port Size: 02 (1/4), Option: C (N.C. Float Type Auto Drain), Attachment: S (Pressure Switch), Semi-Standard 1: C (Bowl Guard), Semi-Standard 2: Standard

Body Size: 20, Thread: Rc: Size 20, 25, 30, 40; M5: Size 10, Port Size: 02 (1/4), Option: CGH (C + G + H), Semi-Standard 1: C (Bowl Guard), Semi-Standard 2: Standard

Dimensions Meter-out type Meter-in type F E D B A C J G K H L B Model A MIN. MAX. MIN. MAX.

Fittings & Tubing Air Cylinders Rotary Actuators 0 L0.1 4 x MM Thread depth J 2 x P (Piping port) A G E H G B NN Effective thread length T (R) D X Mounting nut Width across flats C F N ZZ + Stroke S + Stroke W K N F I NA TT 6 T Model MM L K J I H G F E D C B A S NN NA 34 N R 12-REA25 12-REA32 12-REA40 8 46 32 26.4 2 13 7.5 20.5 8 10 70 15 M5 x 0.8 18.5 30 M26 x 1.5 111 10 8 60 32 33.6 2 16

Main port 3 (3 port valve only) VNA VNB Flow indicator for 2 port valve SGC Dimensions SGH (mm) Main port 1, 2, 3 2 Port 2 x 2 x Pilot port 12(P1), 10(P2) A B Note) C D E F G H I Model 3 Port 3 x 3 x VNC 3 8 1 2 2 x 3 4 2 x 1 3 8 1 8 VNH1 -10A VNH2 -15A VNH3 -20A VNH4 -25A A B A B A B A B 60 80 100 115 217 (219) 246.5 (248.5) 282 (284) 301 (303) 60 77 96 113 46 60 76 85 34 40 50 60 24 36

0 @2 O-ring C Bumper Urethane NBR !1 @3 Nickel plated Electroless nickel plated Reinforcement ring Hexagon socket head cap screw A Carbon steel Carbon steel !2 @4 Replacement Parts: Seal Kit Bore size (mm) Kit no. Contents 40 MGF40-PS Items !

This is not a clean room series product. 4 MACM Series Dimensions W (Workpiece loadable range) 4 x D At maximum offset (A + 2 x S) S F DB DA C X114 X115, X116 U B W A H T H Q PB E PA PD P (Unlocking port) PE P (Locking port) P (Relief port) (Option V only) MACM4, MACM6 MACM2, MACM10 PC PC PC PC PE P (Relief port) (Option V only) PD [mm] Dimensions Model A B C D DA DB E F H P PA PB PC PD

x 0.8 x 8 M6 x 1.0 x8 M6 x 1.0 x10 12REA 50/63 0 -0.2 L NA 33 2-Rc, NPT, G 1/4 14 14 E(h8) E(h8) X D I 4-TC 14 14 Effective thread depth R 23 22 K W 23 25 2 4-M8 x 1.25 25 8-Q 14.5 C 0.1 + Effective thread depth 12 Effective thread depth R B S + Stroke 2 ZZ + Stroke Q x R S TC x R Model L 122 110 K 38 32 C 70 60 X ZZ NA E D B 72.2 58.2 I 70 60 W 12-REA63 12-REA50 100 86 66 53 30-0.033 69

Note Outlet pressure (MPa) 136413 ARM2500 ARM3000 Hexagon socket head cap screw (M5 x 70) 4 With flat washer 136313 IRV Hexagon socket head cap screw (M6 x 85) 4 With flat washer VEX SRH Option/Bracket Assembly SRP Individual IN type can be used as a single unit regulator.

PF3A706H PF3A703H Equivalent to M4 1.5 Nm10% 8 7 Peak display Bottom display OUT2 hysteresis Equivalent to M5 3 Nm10% The following instructions must be followed during maintenance: Turn off the power supply Stop the air supply, exhaust the residual pressure and verify that the air is released before performing maintenance work Otherwise an injury can result.

Item Default setting PF3W7##-L Lock ring Without units selection function Display OUT1 set value OUT1 hysteresis OUT2 hysteresis Bottom value OUT2 set value Peak value [ Unit] Display unit setting [ L] L/min, oC Bracket mounting (PF3W711) Mount the product (with bracket) using the mounting screws supplied (M5 x 4 pcs.).

The tightening torque must be 1 to 1.2 Nm. 2 4 Safety Instructions 4 OUT1 (C/Q) How to reset the product after a power cut or when the power has been unexpectedly removed The settings of the product are retained from before the power cut or de-energizing.

M5 After tightening by hand, tighten additional 1/6 to 1/4 rotation with a tightening tool Tapered thread for Rc port (MGP) and NPT port (MGPTN) Use the correct tightening torques listed below. Before tightening the plug, wrap pipe tape around it.

Solid sphere Position of rotational axis: Through the center of diameter r 2 2 r I = m5 27 - Kinetic energy Table 9 shows the allowable kinetic energy of the rotary table.

Bore size (mm) 32 40, 50, 63 80, 100 Thread size M2.5 X 0.45 X 25 l M3 X 0.5 X 30 l M5 X 0.8 X 40 l Pulling force 4.9N 10N 24.5N Stroke (mm) 2 3 3 e Release lock when mounting or adjusting the cylinder. If mounting is done with lock engaged, lock mechanism may be damaged. * Remove bolt under normal operations.