130 130 130 150 150 150 190 190 65 65 65 75 75 75 85 85 90 90 90 115 115 115 145 145 6 6 6 6 6 6 8 8 72 72 72 86 86 86 106 106 110 110 110 130 130 130 170 170 195 195 195 245 245 245 19 19 19 19 19 19 20 20 10 10 10 10 10 10 20 20 63 63 63 63 63 63 76 76 14 14 14 17 17 17 17 17 90 90 90 126 126 126 197 197 30 30 30 60 60 80 120 120 177 177 177 227 227 227 285 285 110 110 110 130 130 130
to 50C 10 to 50C Ambient and fluid temp.
MGF 40 MGF 63 30, 50, 75, 100 MGF100 Minimum Strokes for Mounting Auto Switches (mm) Switch type D-Z7, D-Z8 D-Y5, D-Y6, D-Y7 Number of pcs. 10 5 1 pc. 15 10 2 pcs.
MGF 40 MGF 63 30, 50, 75, 100 MGF100 Minimum Strokes for Mounting Auto Switches (mm) Switch type D-Z7, D-Z8 D-Y5, D-Y6, D-Y7 Number of pcs. 10 5 1 pc. 15 10 2 pcs.
Duty rrtb = (t + 1 + 0,8)/ (1 + 0.9 + 1 + 0,8+10 X 100 = 50% ..Possible to us, @ Operation Sloppage Figure 2 Duty ratio: (4 + 3)/ (4 +0,2+3 +2DX 100 = 75% '.Not possiblc to use, Senies Ufi tleilnic Artuilo lfifiBli[ It|onoil lllMmce Table receives moment from each direction accordino to cenler of gravity ot work. Overhang ot work should be within the range shown in the figures below.
F A A Lr Lr = 200mm L X S 400 8 60 Table displacement (m) LXSH-150 Table displacement (m) Table displacement (m) 350 7 LXSH-150 LXSH-150 50 300 6 LXSH-125 LXSH-125 250 5 40 LXSH-125 LXSH-100 LXSH-100 200 4 30 LXSH-75 LXSH-100 LXSH-75 3 150 20 LXSH-50 LXSH-75 2 100 LXSH-50 LXSH-50 10 1 50 1 2 3 4 5 6 8 9 7 0 0 0 1 2 3 4 5 6 8 9 10 10 10 7 1 2 3 4 5 6 8 9 7 Weight (kg) Weight (kg) Weight (kg
-SS5V1-10 10-SS5V2-10 10-SS5V3-10 10-SS5V4-10 Note) The values are for individually operated 2 position type manifold bases with 5 stations.
Fittings & Tubing Air Cylinders Rotary Actuators (mm 2) 14/2 (PA/B) 4, 2 (A, B) 1, 5, 3 (P, EA, EB) 4/25/3 (A/BEA/EB) area M8 connector 67 (41) 89 (63) L/M plug connector Grommet C [dm 3/(sbar)] b Cv C [dm 3/(sbar)] b Cv 10-SYJ3143 10-SYJ3243 10-SYJ3343 10-SYJ3443 10-SYJ3543 10-SYJ3123 10-SYJ3223 10-SYJ3323 10-SYJ3423 10-SYJ3523 10-SYJ3133 10-SYJ3233 10-SYJ3 10-SYJ3433 10-SYJ3533 Single Double
N-04 N-06 L-04 L-06 S-04 S-06 LL-04 LL-06 4 6 N-08 8 N-10 10 N-12 12 4 6 L-08 8 L-10 10 L-12 12 4 6 S-08 8 S-10 10 S-12 12 4 6 LL-08 8 LL-10 10 LL-12 12 Precautions Be sure to read before handling.
1 2-color Display Digital Pressure Switch Series ISE70/75/75H ZSE ISE PSE Metal Body Type Metal Body Type Metal Body Type (Die-cast aluminum) Z I SE3 10 MPa 15 MPa 10 MPa 15 MPa 1 MPa 1 MPa For General Fluids For General Fluids PS Z I SE1 2 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
15 18 15 26 40 40 39.5 50 68 68 26 60 75 80 Vertical 3 6 12 2 6 12.5 15 4 10 16 20 4.5 4.5 25 40 Up to 400 10 to 800 5 to 400 3 to 195 20 to 1200 12 to 850 6 to 450 3 to 225 24 to 1100 16 to 750 8 to 450 4 to 125 30 to 1200 20 to 1000 10 to 500 5 to 225 401 to 450 10 to 700 5 to 360 3 to 170 20 to 1100 12 to 750 6 to 400 3 to 225 24 to 1100 16 to 750 8 to 450 4 to 125 30 to 1200 20 to 1000
5 $0 @8 #7 #6 $1 F G Area G (10) Enlarged view F 10, 15 w u i o !1 #2 q !3 r y e @6 @5 @3 $1 #0 @7 #1 10 Component Parts Note No. Description Material No.
MU-D02 MU-D03 MU-D04 MU-D05 MU-D06 8 10 10 14 14 8 10 10 14 14 +0.058 0 +0.058 0 +0.058 0 +0.070 0 +0.070 0 +0.058 0 +0.058 0 +0.058 0 +0.070 0 +0.070 0 Applicable pin DZ 8 10 10 14 16 CZ 8 10 10 14 16 DY 9 11 13 16 16 CX 9 11 13 16 16 DX 18 22 26 32 32 CT 9.5 11 14 17 20 DT 9.5 11 14 17 20 CR 5.3 6.4 8.4 10.5 13 DR 5.3 6.4 8.4 10.5 13 CL 26 42 54 64 72 DL 26 42 54 64 72 Part No.
E s .9 6 5 o 25 50 75 Inpul siqnal (%F.s.) l 25 50 75 Inpul signal (%F.S.)
-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Vacuum switch unit E C ZX1 1 10 Ejector unit Filter unit F ZX1 1 10 Ejector unit PV/V port size Ejector unit nozzle dia.
) (n = 2, 4, 6) Note 3) D-H7 D-H7W D-H7BA D-H7NF (n 2) 2 70 + 45 (n 2) 25 + 45 70 25 10 (n = 2, 3, 4, 5) (n = 2, 4, 6) Note 3) D-C73C D-C80C D-H7C (n 2) 2 80 + 50 (n 2) 30 + 50 80 5 30 (n = 2, 3, 4, 5) (n = 2, 4, 6) Note 3) D-B5 D-B64 D-G5 D-K59 (n 2) 2 70 + 50 (n 2) 25 + 50 5 70 25 (n = 2, 3, 4, 5) (n = 2, 4, 6) Note 3) (n 2) 2 75 + 50 (n 2) 30 + 50 D-B59W 10 75 30 (n = 2, 3, 4,
0.06 ST 15, 20 0.04 0.04 ST 15, 20 0.04 ST 5, 10 0.02 0.02 0.02 ST 5, 10 0.00 0 5 10 15 0.00 0 5 10 15 0.00 0 5 10 15 Load [N] Load [N] Load [N] MXZ16 MXZ16 MXZ16 0.15 0.15 0.15 Table displacement [mm] Table displacement [mm] Table displacement [mm] ST 25, 30 ST 25, 30 ST 25, 30 ST 15, 20 0.10 0.10 0.10 ST 15, 20 ST 15, 20 ST 5, 10 0.05 0.05 0.05 ST 5, 10 ST 5, 10 0.00 0 5 10 15 20 25 0.00
TdH9 TB +0.036 0 +0.036 0 +0.043 0 CLG-020-24 CLG-025-24 CLG-032-24 CLG-040-24 20 25 32 40 42 48 53 60 10 10 10 10 5.5 5.5 6.6 6.6 31 37 38.5 42.5 40 47 47 55 20 25 32 40 36 43 50 58 10 10 10 10 5.5 5.5 6.6 6.6 25 30 35 40 (29.3) (33.1) (40.4) (49.2) 8 10 12 14 8 10 12 +0.043 0 14 CG-020-24A CG-025-24A CG-032-24A CG-040-24A Applicable bore size (mm) Applicable bore size (mm) Part no.