Size (Nominal x Length) Quantity Metric size Inch size TMH-23J TMH-01J M3 x 15 TMH-04J TMH-03J TMH-06J TMH-07J M3 x 20 TMH-06 TMH-07 M4 x 25 TMH-08 TMH-09 TMH-10 M4 x 35 TMH-12 TMH-13 1 Series Holder mounting Select the applicable holder/TMH for each speed controller from the table below.
For details, refer to 3 point preset counter/CEU1 on page 10-12-30, and Multi counter/CEU5 on page 10-12-27 respectively.
Recommended Tightening Torque Recommended tightening torque (Nm) Shock absorber fixing thread size Hexagon wrench width across flats (mm) Model 1.5 M3 x 4 0.6 MXW8 1.5 M3 x 4 MXW12 0.6 1.5 M3 x 4 MXW16 0.6 2 M4 x 5 MXW20 0.8 MXW25 2.5 M5 x 6 1 8-7-9 10 Series MXW Dimensions: MXW8 Stroke: 25, 50 mm Operating port 2-M5 x 0.8 J 10 Width across hexagon socket hole 2.5 5.5 Width across flats 8
10 20 A A 1 30 10 10 15 For D-F9 Rotation range m: Value of the operating range Lm of a single auto switch converted to an axial rotation range.
(1 ) 2. 3. 0 IDFA Series 9-3 (ADH4000-04) 9 2 IDX-OM-W032 10 R 10 R 10-1 10-2 IDFA22E/37E/55E-23-R 10A 30mA IDFA75E-23-R 20A 30mA 10-3 (IDFA55E,75E) (IDFA55E,75E) M5 9.5mm 2 1.25mm L ,N N L () () IDFA Series 10-3 10-1 IDX-OM-W032 10 R 10-4 () () ONOFF 10-5 R 6-4 6-3 T 11-6 11-3 IDFA Series 10-4 10-2 IDX-OM-W032 11 T 11 T T 11-211-3 11-1 1. 2. 3.
10 15 15 20 20 2 pcs. 5 10 15 10 20 15 Auto Switch Mounting Bracket Part Nos.
M3 0.610.63Nm 1) 12mm 10mm -10- 2)L L 4 -11- L (M3X6)L :0.610.63Nm M3 -12- L L M3 (M3X6) :0.610.63Nm 3) :0.610.63Nm 90 -13- 4)DIN L :0.610.63Nm (M3X6)L :0.610.63Nm DIN :0.610.63Nm -14- 5) :0.610.63Nm 3 M3 L DIN -15- 4 4 4 4-3. 3. 3. 3. 1 +24V 2 GND 3 OFF 4 ONOFF OFF 5 0N 6 OFF 7 ON 8 1 ON 9 2 ON ()D ON NPN:GND ONOFF PNP:24V ONOFF NPN:(GND )ONOFF
10 15 15 20 20 2 pcs. 5 10 15 10 20 15 Auto Switch Mounting Bracket Part Nos.
-m-m PFA750-m-m Dry air, N2 Heater type 1 to 10l/min (0.04 to 0.35SCFM) 0.1l/min (0.004SCFM) 5 to 50l/min (0.18 to 1.77SCFM) 0.5l/min (0.02SCFM) l/min, CFM x 10-2 Instantaneous flow rate Cumulative flow rate Display units l, ft3 x 10-1 0 to 0.5MPa (0 to 72psi) 1.0MPa (145psi) 3kPa (50l/min) [0.44psi (1.77SCFM)] 0 to 9l (0 to 35,300 ft3) 0 to 50C (32 to 122F) with no condensation 5% F.S.
Air flow capacity m3/h(ANR) 186 300 462 576 Outlet air temp. oC 10 Note1) The data for ANR is referring to the conditions of 20oC, 1atm. pressure & relative humidity of 65%.
Applicable model AW40-06 AW40 AW30 AW20 AW10 Accessory Bracket assembly Note 1) AR30P-270AS AR30P-260S G36-10-01 GC3-10AS G36-2-01 GC3-2AS AD38 AD38NNote 6) AR40P-270AS AR40P-260S G46-10-02 GC3-10AS G46-2-02 GC3-2AS AD48 AD48NNote 6) AR40P-270AS AR40P-260S G46-10-02 GC3-10AS G46-2-02 GC3-2AS AD48 AD48NNote 6) AR10P-270AS AR10P-260S G27-10-R1 G27-10-R1 Note 3) AW20P-270AS AR20P-260S G36-10
3.92 7.84 15.68 10 1000 10 2.45 1000 1000 2000 4.90 9.80 19.60 Maximum weight of transferred object [kg] 16 10 5 2.5 1.25 Nominal size 25 20 10 5 2.5 It should be noted that the transferred weight accordingly changes. 19 Operation Characteristics Application of power supply Power supply for drive General 3 positions 5 positions General When power supply is applied, the controller is initialized
(packaged together) 50 80 650 F 40 550 G 10 300 H 4 200 J Filter (IN port) Nil Without filter F With filter Note) 100 Note) Flow reduction rate 50 L/min: 5% or less 100 L/min: 5 to 10% 150 L/min: 10 to 15% 80 600 K 40 500 L 10 250 M 4 150 150 Specifications Flow rate (L/min) [at 0.25 MPa] 50 100 150 Power consumption (W) 80 40 10 4 80 40 10 4 80 40 10 4 Type of actuation 2-position 2 port
Option L . 10-1 10.1 SAFETY INSTRUCTIONS FOR USE . 10-1 10.2 SPECIFICATIONS . 10-1 10.3 MOUNT THE HEAVY DUTY AUTO DRAIN . 10-2 10.4 MAINTENANCE . 10-2 Chapter 11 Option R .11-1 11.1 SAFETY INSTRUCTIONS FOR USE . 11-1 11.2 EARTH LEAKAGE BREAKER SPECIFICATION . 11-1 11.3 CONNECTION OF POWER SUPPLY . 11-2 Chapter 12 Option T . 12-1 12.1 SAFETY INSTRUCTIONS FOR USE . 12-1 12.2 OPERATION / ERROR
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 60
Specifications Series PSE200A PSE533 PSE543 PSE563 PSE573 PSE530 PSE540 PSE560 PSE570 Applicable SMC pressure sensor PSE550 PSE531 PSE541 PSE561 PSE532 PSE564 PSE574 PSE575 PSE576 PSE577 Rated pressure range 0 to 2 kPa 0 to 101 kPa 100 to 100 kPa 0 to 100 kPa 0 to 500 kPa 0 to 1 MPa 0 to 2 MPa 0 to 5 MPa 0 to 10 MPa Display/Set pressure range 0.2 to 2.1 kPa 10 to 105 kPa 105 to 105 kPa 10
Dimensions (mm) Weight (g) Effective area (mm2) Recommended flow (m3/min (ANR)) Port size R Model A B C 1 8 1 4 3 8 1 2 3 4 1 1 1 14 64 22 18 ANA1-01 ANA1-02 ANA1-03 ANA1-04 ANA1-06 ANA1-10 ANA1-12 ANA1-14 ANA1-20 4 37 16 10 15 35 60 90 160 280 450 610 0.8 or less 1.2 or less 2.7 or less 4.5 or less 7.0 or less 12.0 or less 20.0 or less 32.0 or less 45.0 or less 84 25 21 98 30 24 111 46
L/min 10 L ON OFF ON OFF 0 -14No.PF-OMO0004CN-E , , 2 5 10 L/min 5 ,51050 L ON-OFF () 1 L/min ,10 11 12 1 L/min SI SI ON-OFF ON 0 ripple -15No.PF-OMO0004CN-E AB.
ZSE50F / ISE50 1 x 10 -5 Pam3/s ZSE60F / ISE60 1 x 10 -10 Pam3/s IP65 Enclosure Panel mount With bracket Option Panel mount + Front side protection cover To confirm working pressure of hydraulic cylinder Application examples To confirm adsorption of workpieces containing water To confirm primary pressure of cleaning line 16-2-26 3 High precision and high resolution 1/2000 (0.1 kPa) Positive
500 1000 1500 0.1 100 200 300 400 500 1000 1500 100 200 300 400 500 1000 1500 100 200 300 400 500 1000 1500 Piston speed (mm/s) Piston speed (mm/s) Piston speed (mm/s) Piston speed (mm/s) ML2B/M1 (Pitch moment) ML2B/M2 (Roll moment) ML2B/M3 (Yaw moment) 30 40 20 20 5 4 3 10 10 5 4 3 ML2B40 ML2B40 2 5 4 3 Moment (Nm) Moment (Nm) Moment (Nm) 2 ML2B32 ML2B32 1 ML2B40 ML2B40 ML2B40 ML2B40 2