Aluminum alloy Aluminum alloy Carbon steel IIR PC PC PC PC PC Rare earth magnet 1 2 3 4 5 6 7 8 9 10 11 12 13 Electroless nickel plated Zinc plated Chrome molybdenum steel Mild steel M5 x 8 M5 139 Series LJ1 Mounting T-slot Bottom Mount LJ1H10/LJ1S10 LJ1H20/LJ1S20 20 0.02 A 92 0.02 A 80 0.02 A: Stroke + 145 A: Stroke + 124 Positioning hole 2-5H10 Positioning hole 2-8H10 8.5 mounting hole
-/22Double Foot Style (M) / CJ2M, CJ2M 10112122Rubber bumper View E GB F NN GC GA Mounting nut Mounting nut Relief port M5 x 0.8 Rod end nut MM NN F Cover surface Piping port 2 x M5 x 0.8 D LY LB LH LT LZ LX LT S + Stroke H NA A 4 x LC Mounting hole Y X X Y NB LS + Stroke Z + Stroke C B 0 0.3 B 0 0.3 Drawing of view (E) (mm) A 10 16 D 15 15 F 4 5 GA 8 8 GB 5 5 H 5 5 MM 28 28 NN M4 x 0.7 M5
2 #3 @6 @7 !9 qo r !3 @1 e #1 #4 @0 !8 t @3 B' CL !7 N@4 CL1 A' A A' A MLGC CNG B MNB @5 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com !
2 #3 @6 @7 !9 qo r !3 @1 e #1 #4 @0 !8 t @3 B' CL !7 N@4 CL1 A' A A' A MLGC CNG B MNB @5 !5 CNA CNS 20, 25: 50 stroke or less Over 100 stroke CLS CLQ Extension locking (Type F) Retraction locking (Type B) MLGP N#2 u #6 y @2 u #6 #2 y #5 @2 i i RLQ MLU ML1C D-X Section B-B' Section B-B' 20Section A-A' !6 !6 Section A-A' Data Component Parts Description Material Note No. !7 !8 !
If screwing without removing dust cover, duct cover might be broken. 3. To use a floating joint to connect the cylinder rod to a driven body, secure it in place by applying a torque that is appropriate for the thread size. Also, if there is a risk of loosening during operation, take measures to prevent loosening, such as using a locking pin or thread adhesive.
If screwing without removing dust cover, duct cover might be broken. 3. To use a floating joint to connect the cylinder rod to a driven body, secure it in place by applying a torque that is appropriate for the thread size. Also, if there is a risk of loosening during operation, take measures to prevent loosening, such as using a locking pin or thread adhesive.
-60GD B1 2 2n1-M5 x 0.8 [4(A), 2(B) port] [With external pilot] 13.3 (Pitch) P = 10.5 13.3 24 24 16.2 16.2 17 36.7 34 34 B 2 B 2 B 2 B 2 B 2 2 B 2 2 B 2 B B R B 2 PE R 3 3 R 3 R 3 1 P 1 P P 1 P 1 X A 4 A 4 A 4 A 4 A 4 A 4 A 4 A 4 A 4 A 4 4-One-touch fitting [1(P), 3(R) port] Applicable tube O.D.: 8 2-One-touch fitting (X, PE port) Applicable tube O.D.: 6 2n-One-touch fitting [4(A), 2(B) port
If the cord is pulled with a greater force, it could lead to a malfunction. When handling the product, make sure to hold it by its body. 3. Never move the switch assembly or loosen the switch assembly mounting screws.
Elbow/Universal Type Flow rate and effective area AS221FM-02 AS221FM-01 Model AS121FM-M5 AS231FM-02 AS231FM-01 AS131FM-M5 3.2, 4, 6 6, 8 Metric sizes 3.2, 4 8, 10 4 6 Tubing O.D. 1/8", 5/32", 3/16" 1/4" 3/16", 1/4" 5/16" 1/4", 5/16" 3/8" Inch sizes 1/8", 5/32" 5/32" 3/16" l/min (ANR) {Nl/min} 38 7 Flow rate 12 Controlled flow Effective area mm 0.6 0.2 0.1 l/min (ANR) {Nl/min} 230 Flow rate
) 2 (same surface) 2 (different surfaces) 1 3 (same surface) 3 (different surfaces) 2 (same surface) 2 (different surfaces) 1 90 55 50 15 10 105 60 60 15 10 105 65 65 15 10 115 75 65 25 15 35 10 5 45 10 5 40 15 10 45 5 5 30 5 5 55 15 10 40 15 10 60 15 15 3 2 1 3 2 1 3 2 1 3 2 1 3 2 1 3 2 1 3 2 1 3 2 1 D-C7 D-C80 D-A7H D-A80H D-H7 D-H7W D-H7BAL D-H7NF Band mounting D-A79W Rail mounting D-F7
N.O. c f a e b d (A) 2 (A) 2 (A) 2 (A) 2 1 (P) 3 (R) 1 (P) 3 (R) h h 3 (R) 1 (P) 3 (R) 1 (P) g g Component parts Replacement parts Description Body Piston plate End cover Piston Spool valve assembly Spool spring No. No. 1 2 3 4 5 6 Material Aluminum die-casted Resin Aluminum die-casted Resin Stainless steel Note White White White Description Note No.
L1 L2 A (2) L3 H (1) T2 T1 D1 D2 Model ASR ASQ AS1200-M3 M3 x 0.5 M3 x 0.5 4.5 6.6 23.5 21.5 8 5 5 20.5 18.5 AS120-M5 M5 x 0.8 M5 x 0.8 8 10 28.3 10.3 9 9 25 22.2 25.5 AS120-U10/32 10-32UNF 10-32UNF AS220-01 30.5 13.2 14.3 14.6 32.4 27.4 12 (12.7) 18 35.5 1/8 1/8 AS220-02 35.3 17.5 18 19.5 34.8 29.8 17 (17.5) 27.2 40.3 1/4 1/4 AS320-03 40.8 19.7 22.5 24.3 40.6 35.6 19 30 45.8 3/8 3/8 AS420
Note 2) The water resistant 2-color solid state switch uses a 3 m lead wire as standard. (0.5 m is not available.) Note 3) For solid state with flexible wire specification, add "-61" after the lead wire length.
, 40, 50, 75, 100, 125, 150, 175, 200 20, 30, 40, 50, 75, 100, 125, 150, 175, 200 26 64 17 10 19 52 74 2 8.5 4 46 36 72 8 30 10 60 37 13 18 47 8 M5 x 0.8 13 M5 x 0.8 7 M5 x 0.8 Rc 1/8 10.5 32 76 21 10 21 62 88 2 9 2 56 42 86 8 38 12 70 37.5 14 26 47.5 9 M6 x 1.0 15 M6 x 1.0 8 M6 x 1.0 Rc 1/8 11.5 MGQM (Slide bearing) A, DB, E Dimensions MGQL (Ball bushing bearing) A, DB, E Dimensions E E
L1 L2 A(2) L3 H(1) T2 T1 D1 D2 Model AS1200-M3 M3 x 0.5 M3 x 0.5 4.5 6.6 23.5 21.5 8 5 5 20.5 18.5 AS1200-M5 M5 x 0.8 M5 x 0.8 25.5 8 10 28.3 10.3 9 9 25 22.2 AS1200-U10/32 10-32 UNF 10-32 UNF AS220-01 27.4 32.4 14.6 14.3 14.1 31.4 36.4 18 12 (12.7) 1/8 1/8 AS220-02 29.8 34.8 19.5 18 18 35.8 40.8 27.2 17 (17.5) 1/4 1/4 AS320-03 35.6 40.6 24.3 22.5 20.8 41.9 46.9 30 19 3/8 3/8 AS420-04 42.4
When very clean air is required, install a separator as mentioned above on the downstream side, or instead of a regulator, use the order made specification (refer to page 35) fitted with a micro mist separator regulator (series AWD). 3.
M1 m x g L1 M1E FE M3E = 0.05 x a x m x L2 (FE = 1.4/100 x a x g x m) = 0.05 x 300 x 3 x 0.04 = 1.8 [Nm] Investigate M3E. a From above, find the value of M3E max. at 420mm/s in Graph 3.
PB H thread depth C Vent hole Note 3) J PC EV Z T M U D K Note 2) L R 4 x O1 thread depth R W A + Stroke B + Stroke S EH M 6 x MO thread depth MR XA H9 depth XA MH Section XX details MA ML + Stroke MC MD Section XX XB XA H9 XA [mm] Incremental encoder Absolute encoder B C D EH EV Without lock With lock Without lock With lock A W Z A W Z A W Z A W Z Size Stroke range [mm] 25 15 to 100 238
Note 3) For M5 and NPT thread types.
x mn x g 1.4 100 Dynamic load FE 1 3 Dynamic moment a x FE x Z M1E a Dynamic moment M2E is not generated.