SMC Corporation of America
Elite Part Number Search
Search Results "CD85KN8-80-B"

Calculate the moment of inertia for A and B separately as shown in the figures on the right. A part B part Procedure Calculation Calculation example 1. Check the operating conditions, dimensions of attachment, etc. Operating model: MHY2-16D Opening time: 0.15 s a = 40 (mm) b = 7 (mm) c = 8 (mm) d = 5 (mm) e = 10 (mm) f = 12 (mm) A part a b c B part e f d 2.

Operating model: MHY2-16D Opening time: 0.15 s a = 40 (mm) b = 7 (mm) c = 8 (mm) d = 5 (mm) e = 10 (mm) f = 12 (mm) A part a b Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com c B part e f d 2.

m 80 m AFJ20-02-80-S/AFJ30-03-80-S/AFJ40-04-80-S AFJ20-02-80-T/AFJ30-03-80-T/AFJ40-04-80-T 12 12 AFJ20-02-80-T AFJ30-03-80-T AFJ20-02-80-S AFJ30-03-80-S AFJ40-04-80-S 10 10 Pressure drop [kPa] Pressure drop [kPa] 8 8 AFJ40-04-80-T 6 6 4 4 2 2 Water drop removal type Nominal filtration rating: 80 m Large flow type Nominal filtration rating: 80 m 0 0 0 100 200 300 400 500 600 800 700 900 Flow

B A Through-hole (Standard) Both ends tapped style RHC Note 1) Since 12 uses a common tube for both A and B, only B is used for part no. denotation.

N.O. 140 (80) 1/8 Base mounted (with sub-plate) 135 (75) 136 (76) 157 (97) V100 1/4 Note) Value for DC. Add 3 g for AC. ( ): Without sub-plate.

80 g EX510-S02: 50 g EX510-S02A, B, C: 90 g (including accessories) EX Mass Dimensions EX510-S01A EX510-S01 70 58 PWR COM 33 19.6 PWR 14 COM 64 2 x M3 Mounting hole 44 EX510-S01B PWR COM EX510-S02C 31 47.6 (24.5) PWR COM 1715 Series EX510 Parts Description You can place an order for the manifold (valve series mentioned below) with the SI unit.

(Looked by double solenoid valve) (Looked by double solenoid valve) SOL. location B (*) B (*) B B A B A B A B A B A A A A B A B A SOL. location VQC 3 position 3 position Double Double Double Double SI unit Single Single SI unit Single Single SQ Stations 1 2 3 4 5 Stations 1 2 3 4 5 VQ0 The places of asterisk are not used.

Normal output Reversed output P_1(P_2)=A-(A-B)/4 n_1(n_2)=B+(A-B)/4 A = Maximum pressure H_1(H_2)= (A-B)/2 H_1(H_2)= (A-B)/2 B = Minimum pressure If setting is not necessary press the UP and DOWN buttons simultaneously for 1 second or longer. -46No.PS-OMW0012-C [F 6] Fine adjustment of display value This function is to manually perform a fine adjustment of the displayed pressure value.

Terminal block 5 External sensor: Terminal B of resistance temperature detector 6 External sensor: Terminal B of resistance temperature detector 7 FG D A Pin No. Signal contents A short pin is installed between No. 1 and No. 2 pins to short-circuit it (Remote ON) when shipped.

A B-1 Brown 2 Cable length (L) A A-1 Red 1 B B-2 Orange 6 1 1.5m B A-2 Yellow 5 COM-A/COM B-3 Green 3 3 3m COM-B/ A-3 Blue 4 5 5m Shield Cable color Terminal no.

Connector pin numbers -16No.PS-OMV1001-C Internal circuit and wiring example Z/ISE30A(F)X576 ~ X580 Output specification -N NPN open collector 1 output Max. 28 V, 80 mA Residual voltage 1 V or less -P PNP open collector 1 output Max. 80 mA Residual voltage 1 V or less -A NPN open collector 2 outputs Max. 28 V, 80 mA Residual voltage 1 V or less -B PNP open collector 2 outputs Max. 80 mA Residual

A B 63 63 80 85 90 100 C Port size Rc(PT) INA-11-402 INA-11-403 INA-11-404 INA-11-405 INA-11-406 INA-11-407 Model No. 1/4 15 15 15 20 22 22 141 164.5 170 180 230 251 3/8 1/4 , 3/8 , 1/2 3/4 B C D E F Port size Rc(PT) 3/4 , 1 1 Model No. A 1 2 150 165 42.7 76.3 45 65 40 60 35 40 80 80 ALBA90-10 ALBA90-20 1.17-24

B C D E F G H 148 206 246 Model MHL2-40D MHL2-40D1 MHL2-40D2 80 138 178 188 246 286 288 406 486 116 174 214 348 466 546 72 130 170 12-4-13

Max. applied voltage: 30 V, Load current 80 mA Internal voltage drop: 1.5 V or less When used as a switch output device Max. applied voltage: 30 V, Load current 80 mA Internal voltage drop: 1.5 V or less -19No.PF-OMA1011-A PFG203-# IO-Link/PNP open collector 1 output + PNP open collector 4 output specification Used as IO-Link device Load current 80 mA Internal voltage drop: 1.5 V or less

rib O Deep type B Bellows type List o Pad dia.

rib O Deep type B Bellows type List o Pad dia.

38 50 64 4.9 6.4 8 11.7 3 4 5 6 6.5 8 9.5 11 3.4 4.5 5.5 6.6 A B A B A B A B 71.6 79.6 95 118 142 164 202 80 14.8 8.5 14 9 A B 55 MY-S40 M10 x 1.5 A B 100 18.3 10.5 17.5 11.5 70 M12 x 1.75 MY-S63 Guide for Side Support Application For long stroke operation, the cylinder tube may be deflected depending on its own weight and the load weight.