Accessory (Option) Tank capacity ID D With auto-drain F Companion flange Port size Capacity ( l ) 100 200 400 500 700 1000 1500 Applicable compressor (kW) 5.5 Symbol AMG 6C 04 Rc 06 14 20 30 1 2 Rc 3 4 Rc 1 1 2 2B flange 3B flange 40 4B flange AT6C AT11C AT22C/37C AT55C/75C AT125C AT150C/220C 11C 11 22C 22 AFF 37C 37 55C 55 AM 75C 75 125C 125 2000 150C 150 3000 220C 220 Misc. 14-16-1 2 Series
Twists or crushing of connected tubes d. Hardness and deterioration of connected tubes e. Air leakage 192
(Or None in the Case of No Switch), Lock Unit Built-in Magnet: D (Built-in), Lock Unit Switch Type: M9B--Solid State , Gen. Purpose, 2 Wire, Horizontal, 0.5M
(Or None in the Case of No Switch), Lock Unit Built-in Magnet: D (Built-in), Lock Unit Switch Type: M9B--Solid State , Gen. Purpose, 2 Wire, Horizontal, 0.5M
: 4 pcs., Lock Unit Built-in Magnet: D (Built-in), Lock Unit Switch Type: M9NZ--Solid State , Gen.
Cylinder (Tube) Inner Diameter(φ): 125, Stroke(mm): 200, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure
Cylinder (Tube) Inner Diameter(φ): 125, Stroke(mm): 200, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure
Cylinder (Tube) Inner Diameter(φ): 125, Stroke(mm): 350, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure
Cylinder (Tube) Inner Diameter(φ): 125, Stroke(mm): 200, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure
Cylinder (Tube) Inner Diameter(φ): 125, Stroke(mm): 200, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure
Cylinder (Tube) Inner Diameter(φ): 125, Stroke(mm): 350, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure
(Or None in the Case of No Switch), Lock Unit Built-in Magnet: D (Built-in), Lock Unit Switch Type: M9N--Solid State , Gen. Purpose, 3 Wire NPN, Horizontal, 0.5M
Front view Right side view Metric Size Model Applicable tubing O.D. d D1 Release button D2 D3 D4 D5 L1 L2 L3 L41 L5 L6 L7 L8 M1 W1 W2 X1 X2 Weight [g] X(X) Y Max.
A B C D E F G H Composition of assembly Set nut (1349172) ARM2500 136314 30 34 70 5.4 15.4 55 2.3 M33 x 1.5 Bracket (B220) Set nut (131532) ARM3000 136414 41 40 75.5 6.5 8 53 2.3 M42 x 1.5 Bracket (B320) Note) Tighten the set nut securely and fix it.
1500 14 20 10, 11 12 Flow (l/min (ANR)) Effective area (mm2) Effective area (mm2) Flow (l/min (ANR)) 12 1000 10 8 10, 11, 12 08, 09 15 500 06, 07 10 6 4 500 5 2 0 5 10 0 0 0 5 10 Needle rotation (Turns) Needle rotation (Turns) 4.1-14 Series ASD Dimensions/Metric Applicable tube O.D. d ASD230F ASD330F/430F ASD530F/630F Applicable tube O.D.d L2 L2 L3 L3 M M D2 D2 L1 L1 L4 L4 H H (Width across
A B C D E F G H Composition of assembly Set nut (1349172) ARM2500 136314 30 34 70 5.4 15.4 55 2.3 M33 x 1.5 Bracket (B220) Set nut (131532) ARM3000 136414 41 40 75.5 6.5 8 53 2.3 M42 x 1.5 Bracket (B320) Note) Tighten the set nut securely and fix it.
Fittings & Tubing Air Cylinders Rotary Actuators 0 L0.1 4 x MM Thread depth J 2 x P (Piping port) A G E H G B NN Effective thread length T (R) D X Mounting nut Width across flats C F N ZZ + Stroke S + Stroke W K N F I NA TT 6 T Model MM L K J I H G F E D C B A S NN NA 34 N R 12-REA25 12-REA32 12-REA40 8 46 32 26.4 2 13 7.5 20.5 8 10 70 15 M5 x 0.8 18.5 30 M26 x 1.5 111 10 8 60 32 33.6 2 16
After washing the element, make sure the base seal is properly mounted. 500 A Vertical Suction Filter FHIA Series Dimensions Differential pressure indicator 16 B (34) F OUT Removal dimension K H F OUT D E C H Differential pressure indication switch FH FH 62 HOW (65) F IN 4 x I OUT A J G (mm) A B C D E F G H I J K Model Weight (kg) FHIA-04 FHIA-06 FHIA-08 FHIA-10 FHIA-12 FHIA-16 FHIA-20 FHIA
1.0 x8 M6 x 1.0 x10 12REA 50/63 0 -0.2 L NA 33 2-Rc, NPT, G 1/4 14 14 E(h8) E(h8) X D I 4-TC 14 14 Effective thread depth R 23 22 K W 23 25 2 4-M8 x 1.25 25 8-Q 14.5 C 0.1 + Effective thread depth 12 Effective thread depth R B S + Stroke 2 ZZ + Stroke Q x R S TC x R Model L 122 110 K 38 32 C 70 60 X ZZ NA E D B 72.2 58.2 I 70 60 W 12-REA63 12-REA50 100 86 66 53 30-0.033 69 55 M10 x 1.5 x
M L3 L2 L1 d T1 D1 D2 H2 H1 Max.