SMC Corporation of America
Elite Part Number Search
Search Results "CDM2E20-50Z-NW-M9BVL"

Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard / With rod detent function, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): -, Cushion: Rubber bumper at both ends, Port thread type: M5 x

Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard / With rod detent function, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): -, Cushion: Rubber bumper at both ends, Port thread type: Rc, Auto

Cylinder (Tube) Inner Diameter(φ): 12, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard / With rod detent function, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): -, Cushion: Rubber bumper at both ends, Port thread type: M5 x

Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard / With rod detent function, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): -, Cushion: Rubber bumper at both ends, Port thread type: Rc, Auto

Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard / With rod detent function, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): -, Cushion: Rubber bumper at both ends, Port thread type: Rc, Auto

Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard / With rod detent function, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): -, Cushion: Rubber bumper at both ends, Port thread type: NPT,

Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard / With rod detent function, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): -, Cushion: Rubber bumper at both ends, Port thread type: Rc, Auto

Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard / With rod detent function, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): -, Cushion: Rubber bumper at both ends, Port thread type: NPT,

Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard / With rod detent function, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): -, Cushion: Rubber bumper at both ends, Port thread type: Rc, Auto

Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Cushion: Rubber cushion, Specification: Built-in magnet, Port thread type: Rc, Auto

Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard / With rod detent function, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): -, Cushion: Rubber bumper at both ends, Port thread type: Rc, Auto

Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Environment, Applications: Standard, End Locking: No, Valves: -, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Auto Switches: M9BV, Lead Wire Length(m): 3, The number of

Magnet: D (Built-in Magnet), Cushion Type: A (Air Cushion), Bore Size: 32mm, Stroke: 50mm, Thread: Male Rod End, Rod End Bracket: None, Auto Switch: M9BV--Solid State, Gen. Purpose, 2 Wire, Vertical, Lead Wire or Prewired Connector: L (3m)

Bore Size: 10mm, Stroke: 50mm, Auto Switch: M9BV--Solid State, Gen. Purpose, 2 Wire, Vertical, Lead Wire or Prewired Connector: L (3m)

Magnet: D (Built-in Magnet), Cushion Type: A (Air Cushion), Bore Size: 50mm, Stroke: 50mm, Thread: Male Rod End, Rod End Bracket: None, Auto Switch: M9BV--Solid State, Gen. Purpose, 2 Wire, Vertical, Lead Wire or Prewired Connector: L (3m)

) KF (NW), K (DN) Main material Body: aluminum alloy, Bellows: SUS316L, Main part: SUS304 and FKM (standard sealant material) Surface treatment for body Outside: hard anodized Inside: basis material Actuation pressure MPa(G) 0.4 to 0.7 Air consumption cm3 Note 2) for 0.5MPa 31 61 220 390 680 1420 Port size M5 Rc 1/8 Weight kg 0.28 0.47 1.1 1.7 3.1 5.1 9 XL-OMS0001-B 4-2.

) KF (NW) , K (DN) Main material Body: aluminum alloy, Bellows: SUS316L, Main part: SUS304 and FKM (standard sealing material) Surface treatment for body Outside: hard anodized Inside: basis material Actuation pressure MPa(G) 0.4 to 0.7 Air consumption cm3 Note 2 for 0.5MPa 19 46 200 360 660 1350 3000 5150 Port size M5 Rc 1/8 Rc 1/4 Weight kg 0.25 0.45 1.1 1.6 2.9 5.0 10.6 18.5 7 XL*-OML0013

XLC-16 XLC-25 XLC-40 XLC-50-1 XLC-63-1 XLC-80-1 XLC-100-1 XLC-160-1 16 25 40 50 63 80 100 160 560(5150) -5 Pa (abs) 110 l/s 1 5 14 45 80 160 200 300 800 10 (FKM) 1.310 Pam 3/S -11 (FKM) 1.310 KF(NW) KF(NW)K(DN) SUS316LSUS304FKM() 2 MPa (G) 0.30.6 0.40.6 cm 3 3 0.5MPa 38 91 430 280 500 1000 2300 3700 M5 Rc 1/8 Rc1/4 kg 0.28 0.46 1.1 1.4 2.3 4.0 8.7 14.5 1) 2) Y-VAC2 3) 1 7 XL-OMV0002

Malfunction RA1 OFF ON MC MC SK Emergency stop switch Driver Servo amplifier Servo motor (Note 6) MCCB CNP1 MC (Note 10) 1-phase 200 V AC to 240 V AC L1 CNP3 (Note 5) U U L2 Motor V V L3 M W NW P3 (Note 1) (Note 9) P4 CNP2 P+ C (Note 2) D (Note 10) Encoder (Note 3) CN2 L11 Encoder cable L21 (Note 7) Main circuit power supply CN1 Forced stop 2 EM2 CN1 24 V DC (Note 11) (Note 4) Servo-on SON

SV1000 SV2000 SV3000 0 NW QW 1 2 3 P, E port position Input block Supply/Exhaust block assembly specification Input block type Without input block M12: 2 inputs M12: 4 inputs M8: 4 inputs (3 pins) A, B port size For mixed mounting, indicate the port size, such as C3 or C4, instead of a "" in the a section of the station table.