Magnet: Built-in, Mounting: B [Through Hole (Standard; 12 through 63 Bore)], Bore Size: 50mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 10mm, Body Option: Rod End Male Thread, Auto Switch Groove: None (for 12-25 Bore w/o Magnet), Auto Switch: A90--Reed, AC Volt, Horizontal, Lead Wire or Prewired Connector: 3m, Number: 1 pc., Speed Control Type: -, Applicable Tubing
Magnet: Built-in, Mounting: B [Through Hole (Standard; 12 through 63 Bore)], Bore Size: 50mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 10mm, Body Option: Rod End Male Thread, Auto Switch Groove: Auto Switch Mounting Grooves, Auto Switch: A90--Reed, AC Volt, Horizontal, Lead Wire or Prewired Connector: 3m, Number: 1 pc., Speed Control Type: -, Applicable Tubing: -
Magnet: Built-in, Mounting: Front Flange, Tube Material: Aluminum Tube ø125~ø160, Steel Tube ø180~ø300, Bore Size: 200mm, Port Thread: NPT, Stroke: 500mm, Option: w/o Rod Boot, Cushion: Rear Side, Auto Switch: A90--Reed, AC Volt, Horizontal, Lead Wire or Prewired Connector: 3m, Number: 1 pc.
Magnet: Built-in, Mounting: Through Hole, Both Ends Tapped, Bore Size: 25mm, Stroke: 10mm, Action: Single Acting Spring Extend, Option: Standard (Rod End Female Thread), Auto Switch: A90--Reed, AC Volt, Horizontal, 0.5M, Lead Wire or Prewired Connector: 3m, Number: 1 pc., Thread: -
Bearing Type: Slide bearing, Bore Size: 32mm, Port Type: Bore 12-16: M5x0.8; Bore 20-100: Rc, Stroke: 50mm, Auto Switch: A90--Reed, AC Volt, Horizontal, Lead Wire or Prewired Connector: 3m, Number: 1 pc.
Magnet: Built-in Magnet, Bore Size: 16 mm, Port Thread: Bores 6~25: M5, Bore 32: Rc 1/8, Stroke: 15 mm, Action: Single Acting Spring Return, Auto Switch: A90--Reed, AC Volt, Horizontal, 0.5M, Lead Wire or Prewired Connector: 3 m, Number: 1 pc.
Magnet: Built-in Magnet, Bore Size: 20 mm, Port Thread: Bores 6~25: M5, Bore 32: Rc 1/8, Stroke: 5 mm, Action: Single Acting Spring Return, Auto Switch: A90--Reed, AC Volt, Horizontal, 0.5M, Lead Wire or Prewired Connector: 3 m, Number: 1 pc.
Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 30, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket:
Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 10, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: High rigidity / high precision high class guide, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet
Magnet: Built-in, Mounting: B [Through Hole (Standard; 12 through 63 Bore)], Bore Size: 32mm, Stroke: 50mm, Body Option: Standard (Rod End Female Thread), Auto Switch Groove: None (for 12-25 Bore w/o Magnet), Auto Switch: A90--Reed, AC Volt, Horizontal, Lead Wire or Prewired Connector: 3m, Number: 1 pc.
Bore Size: 20mm, Thread Type: Bore 8-16: M Thread, Bore 20-25: Rc, Stroke: 250mm, Option: B (2 Shock Absorbers), Auto Switch: A90--Reed, AC Volt, Horizontal, Lead Wire or Prewired Connector: L (3m), Number: S (1 pc.)
Bore Size: 25mm, Port Thread: TN (NPT Thread), Stroke: 1800mm, Stroke Adjusting Unit: w/o Adjusting Unit, Auto Switch: A90--Reed, AC Volt, Horizontal, Lead Wire or Prewired Connector: L (3m), Number: S (1 pc.)
Magnet: D (Built-in Magnet), Mounting: F (Rod Flange), Bore: 63mm, Port Thread: Rc, Stroke: 200mm, Cushion: Rod Boot None; Air Cushion on Both Sides, Pivot Bracket: No Bracket, Rod End: No Bracket, Auto Switch: A90--Reed, AC Volt, Horizontal, Lead Wire or Prewired Connector: L (3m), Number: S (1 pc.)
Bore Size: 10mm, Stroke: 40mm, Auto Switch: A90--Reed, AC Volt, Horizontal, Lead Wire or Prewired Connector: L (3m), Number: S (1 pc.)
SMC has redesigned the CQ2 compact cylinder with a new body, making it possible to mount auto switches on any of the 4 surfaces, depending on the installation conditions. Auto switch mounting grooves have replaced the CQ2s mounting rails, preventing projection of auto switches and improving ease and safety of work.Double acting, double rod, compact cylinder, Bore sizes *: 12, 16, 20, 25,
Magnet: D (Built-in Magnet), Mounting: T (Head Trunnion), Bore Size: 32mm, Stroke: 50mm, Action: S (Single Acting, Spring Return), Thread: Male Rod End, Pivot Bracket: None, Rod End Bracket: W (Double Knuckle Joint), Auto Switch: A90--Reed, AC Volt, Horizontal, Lead Wire or Prewired Connector: L (3m), Number: S (1 pc.)
Magnet: D (Built-in Magnet), Mounting: T (Head Trunnion), Bore Size: 32mm, Stroke: 50mm, Action: S (Single Acting, Spring Return), Thread: Male Rod End, Pivot Bracket: N (Pivot Bracket not Assembled), Rod End Bracket: W (Double Knuckle Joint), Auto Switch: A90--Reed, AC Volt, Horizontal, Lead Wire or Prewired Connector: L (3m), Number: S (1 pc.)
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
Magnet: D (Built-in), Series: 85 (Standard), Head Cover Type: N (Basic Integrated Clevis), Bore Size: 25mm, Stroke: 50mm, Action: T (Spring Extend), Mounting Bracket: U (Trunnion), Accessory: W (Double Knuckle Joint), Auto Switch Mounting Type: B (Band), Auto Switch: A90--Reed, AC Volt, Horizontal, Lead Wire or Prewired Connector: L (3m), Number: S (1 pc.)
Bore Size: 16mm, Stroke: 125mm, Adjuster: A (Adjusters Both Ends), Function: Standard, Auto Switch: A90--Reed, AC Volt, Horizontal, Lead Wire or Prewired Connector: L (3m Lead Wire), Number: S (1 pc.)