200 VXB215 B E(H) 100 300 400 500 600 200 VXB215 C F(H) 100 300 400 500 600 700 800 200 Flow rate Q [kg/h] How to read the graph The sonic range pressure to generate a flow rate of 300 kg/h is P1 0.3 MPa for the VXB215C F(H).
Model XL-25-2 XL-40-2 XL-50-2 XL-63-2 XL-80-2 Rated voltage for heater 90 to 240 VAC Heater assembly quantity 1 1 1 1 H4 100C 100 V 200/40 200/50 400/100 600/150 Heater assembly quantity used Heater power W (Nominal value) Inrush/Power consumption (Option symbol, Operating voltage) 200 V 800/40 800/50 1600/100 2400/150 Heater assembly quantity 1 1 1 1 2 H5 120C 100 V 200/40 400/70 400/
Suction flow rate [L/min (ANR)] Note 1) Air consumption [L/min (ANR)] Discharge flow rate [L/min (ANR)] Suction flow rate [L/min (ANR)] Note 1) Air consumption [L/min (ANR)] Discharge flow rate [L/min (ANR)] 1,600 700 ---6 ---6 Discharge flow rate Discharge flow rate 1,400 Vacuum pressure [kPa] Vacuum pressure [kPa] 600 Vacuum pressure Vacuum pressure ---5 ---5 1,200 500 ---4 ---4 1,000 400
B 300 D 1300 E 1430 F 1520 G 20 H 720 M16 x l 400 Anchor bolt M20 x l 500 AMD800 AMD900 400 550 560 745 300 300 1320 1380 1480 1610 1585 1740 24 24 4B, 6B 870 M20 x l 500 AMD1000 Please refer to Made to Order Specifications of Series AMD on pages 14-20-55 to 14-20-57. 14-20-28
RSH20, 32 Graphq Graphw 1.0 RSH32 RSH32 RSH32 Bore size 50, 63, 80/ m =0 Bore size 50, 63, 80/ m =0.1 RSH20 RSH20 RSH20 0.9 Operating pressure : P (MPa) 1300 1300 0.8 80 0.7 1200 1200 0.6 1100 1100 0.5 1000 1000 0.4 900 900 0.3 63 80 800 800 0.2 50 Weight : W (kg) Weight : W (kg) 700 700 0.1 600 600 100 200 300 400 500 0 63 500 500 Lateral load: W (N) 50 400 400 RSH50, 63, 80 300 300 1.0
: Seal Kit 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600 50, 63 Bore size (mm) Contents Kit no. 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600, 700 80, 100 40 50 63 80 100 CA2Y40-PS Rod seal 1 pc.
Selection of applicable model 78.5 94.2 110 173 188 236 393 Selection of applicable model According to Data D , the tentatively selected RB2015 satisfies Me = 260 kg < 400 kg at = 0.3. Ultimately, it will result in an operating frequency of n20 < 25, without causing a problem.
.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 10 to 60C Ambient & fluid temperatures 50 to 400 mm/s Piston speed Rubber bumper on both ends Bumper Non-lube Lubrication +1.5 0 mm Stroke length tolerance Manual type Table rotation system Right, left, free repetetive rotation Table rotation direction
Standard stroke Maximum manufacturable stroke (mm) Standard stroke (mm) Bore size (mm) Suffix for stroke adjusting unit 25 32 40 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000 2000 2000 2000 Nil S 2 pcs. 1 pc.
-X 20Data Table (1) 100 Total operation cycles (10,000) 50 40 30 20 10 100 200 300 400 500 700 1000 Stroke (mm) Inner Cover Holding Screw Tightening Torques [Nm] Tightening torque Model Screw size CYV15 0.3 M3 x 0.5 CYV32 2.45 M6 x 1 Plate Stroke adjustment screw (inner cover) Hexagon wrench Inner cover holding screw direction + direction 8-18-11
.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Maximum speed (mm/s) 100 All strokes 200 300 400 600 800 500 Stroke (mm) CX (1) (2) (3) 8 Selection graph D(4) (5) (6) (7) 12 to 40 -X Horizontal Mounting 20Data W W Mounting orientation L Direction for L can be up, down, left, right, or diagonal
Body materaial Code Brass 300 SS series B C Gauge port (Inlete, Outletr) Porting Configuration Ports Pressure gauge Ports Code 2 ports 4 ports 4 ports (Reverse port) Code psig/bar unit MPa unit r e 2P 4P No gauge port No pressure gauge (Connections: 1/4 inch NPT) No code w q w q 0 4PQ 400 psig/bar1) 600 psig/bar 1) 1000 psig/bar1) 2000 psig/bar1) 4000 psig/bar1) 6000 psig/bar1) 4 6 10 20
500 100 200 300 400 500 100 200 300 400 500 Elimination ratio (%) Elimination ratio (%) Elimination ratio (%) 75 70 60 50 40 30 20 10 0 1 5 10 50 30 100 1 5 10 50 100 Flow-back count Flow-back count Flow-back count Explanation of graph Explanation of graph Example: Elimination ratio and concentration after using the FHM-100 for one hour under the following conditions.
Fluoropolymer Fittings LQ series 20C 100C 200C 260C 0.5 0.19 0.09 0.04 2.0 400 290 0.7 0.26 0.12 0.05 2.8 220 160 1.0 0.43 0.20 0.08 4.6 95 60 1.0 0.62 0.28 0.12 6.7 60 30 1.0 0.73 0.34 0.14 7.9 35 20 1.0 0.62 0.28 0.12 6.7 25 20 1.0 0.92 0.42 0.17 9.9 10 6 1.0 0.59 0.27 0.11 6.4 20 12 0.6 0.24 0.11 0.05 2.6 220 160 0.7 0.27 0.12 0.05 2.9 130 110 0.9 0.33 0.15 0.06 3.6 100 65 1.0 0.43 0.20
L2 = 16n + 73 n: Station (Maximum 24 stations) 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 L1 L2 (L3) (L4) 85 101 117 133 149 165 181 197 213 229 245 261 277 293 309 325 341 357 373 389 405 421 437 105 121 137 153 169 185 201 217 233 249 265 281 297 313 329 345 361 377 393 409 425 441 457 137.5 150 162.5 187.5 200 212.5 225 250 262.5 275 300 312.5 325 337.5 350 375 387.5 400
Operate under the following conditions to avoid malfunction. < N.O. type > Operating pressure: 15 psi [0.1 MPa] or more Operate the compressor at 3.7 kW (14 scfm [400 L/min (ANR)]) or more.
Description Material Note ALF400, 400-06 ALF500, 600 ALF800, 900 Platinum silver painted Body Housing Aluminum die-casted Aluminum casted Aluminum die-casted 1 2 Platinum silver painted Replacement Parts No. Description Material Part no. Qty.
Made to Order How to Order 2 F 06 A 200 AS Lubricant: Vaseline -X12 Example) AS2002F-04A-X12 Body size Made to Order Grease-free (Seal: Fluorine-coated) + Restrictor (Without check valve) -X21 100 M5 standard 200 1/8 standard 205 1/4 standard 300 3/8 standard 400 1/2 standard Push-lock type Example) AS2002F-04A-X21 * Not particle-free Applicable tubing O.D.1 Metric size Inch size 23 3.22