SMC Corporation of America
Elite Part Number Search
Search Results "CHD2FLB50C-1000-H"

Body mounting dimension AC AC Window for removal H AD Window for removal H AD Body mounting dimension Body mounting dimension Element Element FH FH (mm) adjustment range A B C D F G H I L M S U V r AC AD AG 1 2 3 4 5 Standard T dimension Port size (Nominal size) T dimension HOW 1/2B (04) 3/4B (06) 1B (08) 1 1/4B (10) 1 1/2B (12) 2B (16) 2 1/2B (20) 3B (24) 215 215 215 265 265 265 325 325

Grease pack part no.: GR-S-010 (10 g) D-X 511 MGPW Series 20 to 63/MGPWM Stroke Z 4 x YY depth YL Stroke Z L 4 x MM depth ML 4 x NN through DA DB H V U X T R PW 2 x P OL GA GB 4 x OA through FA FB 2 x OB counterbore Q J K C + Stroke B + Stroke E S G A + Stroke For intermediate strokes other than standard strokes, refer to Manufacture of Intermediate Strokes on page 499.

(Values at the initial period) Vibration resistance: No malfunction occurred in a one-sweep test between 45 and 1000 Hz. Test was performed at both energized and de-energized states in the axial direction and at the right angles to the main valve and armature.

Do not drop, bump or apply excessive impact (1000 m/s2) when handling. Even if the switch body is not damaged, the switch may suffer internal damage that will lead to malfunction. 3. Hold the product from the body side when handling. The tensile strength of the power cord is 49 N, and pulling it with a force greater than this can cause failure. Hold by the body when handling. 4.

1 Air Tank Series AT Model/Standard Specifications AT11C AT22C AT37C AT55C AT75C AT125C AT150C (1) AT220C (1) AT6C Model Fluid Tank capacity (l) 400 500 700 Compressed air 1000 1500 2000 3000 100 200 Max. operating pressure (MPa) Port size 0.97 Rc 1/2 Rc 3/4 Rc 11/2 2B flange 3B flange 4B flange Set pressure for safety valve (MPa) 0.97 1.46 0 to 100 Proof pressure (Under water pressure) (

(Rated voltage 125 V, Plug JIS C 8303, Inlet IEC 60320-C13) *1 Measured with a high pressure probe of 1000 M and 5 pF *2 Measurement value based on a charged plate (Dimensions: 150 mm x 150 mm, Capacitance: 20 pF) as defined in the U.S.

Height: 30 mm (LOW type), 100 mm (HIGH type) W H L2 T L1 [mm] Model C(L)KQG32 Compact cylinder type (Guide pin diameter: 12) C(L)KU32 Plate cylinder type (Guide pin diameter: 12) C(L)KQG50 (Guide pin diameter: 13) Clamping height LOW type HIGH type LOW type HIGH type LOW type HIGH type Clamping height H 30 100 30 100 24 54 Body thickness T 50 29 66 Body width W 50 70 66 Body length L1 127

For Safety Instructions and Common Precautions, refer to pages 8-34-3 to 8-34-6. 1.05 MPa 0.7 MPa 0.1 MPa 10 to 60C (No freezing) Note) 50 to 1000 mm/s Selection M5 x 0.8 Rc 1/8 (NPT 1/8, G 1/8) Slide bearing, Ball bushing bearing (Same dimensions for both) Caution Air cushion (Both ends) 1. Operate the cylinder until the stroke end.

Description Material 1 Pipe PPS 2 O-ring FKM 3 Attachment Brass 4 Spacer FKM w e e w 8 LFE Series Dimensions Integrated display type LFE1/2/3 K Width across flats H I L 4 x O J 2 x Port size M C N D Q P 1.41 E A B F G 1 For integrated display type The electrical entry for lead wire and M12 connector does not rotate and is limited to only one entry direction.

Extend upward from 300 mm/s on the horizontal axis of the graph to the intersection point with the line for a tube bore size of 50 mm, and then extend leftward from this point to find the load of 40 kg. 4 JMB Series Dimensions Basic: JMDBB MM Width across flats KA 2 x P (Rc, NPT, G) 4 x J G G D E B C H1 AL A N F H ZZ + Stroke S + Stroke N M K B C B1 Dimensions [mm] Bore size Stroke range

B A G A mm A B C D E Fn G H J XLC-16 40 110 38 1 30 17 40 26 XLC-25 50 120 48 1 12 40 26 39 27.5 XLC-40 65 171 66 2 11 55 41 63 36 9 XL-OMV0002 4-2.162580,100,160 C E D C E E (KF ) (K ) Fn Fd J K H B A G A mm A B C D E Fn Fd G H J K XLC-50 70 183 80 31 10.5 75 52 77 29 10.5 XLC-63 88 209 100 39 11 87 95 70 76.5 36 9 XLC-80 90 250 117 45.5 11 114 110 83 105 44 9 XLC-100 108 317.5 154 55

Through-hole/Both ends tapped common (Basic) S T R Q H (Rod size) AE (Rc, NPT, G) (2 locations) (Port size) E effective thread depth F Yh9 Z X 5.5 (The dimension on the opposite side is the same.) I (4 locations) 0.1 0.2 D G W AC (4 locations) (The dimension on the opposite side is the same.) A AA C J L L J K (4 locations) Flat washer With 4 pcs.

V(mm/s) = x 1000 4. Keep wiring as short as possible. As the length of the wiring to a load gets longer, the rush current at switching ON becomes greater, and this may shorten the products life.

Bracket C MPa ISE20C(H) ISE20C: 0.050 MPa/ZSE20C: 5.1 kPa/ ZSE20CF: 5.0 kPa/ISE20CH: 0.100 MPa "Nil" or M Hysteresis Self tapping screws: Nominal size 3 x 8L kPa ZSE20C(F) Self tapping screws: Nominal size 3 x 10L Safety Instructions Bracket A ISE20C(H) Delay time 1.5 ms or less psi P ZSE20C(F) Display color OUT1 ON: Green/OUT1 OFF: Red : Arbitrary display These safety instructions are intended

Before Use Digital Pressure Switch ZSE20C(F)-L/ISE20C(H)-L Mounting and Installation Outline of Settings [Measurement mode] Function Selection Mode Installation Mounting Mount the optional bracket and panel mount adapter to the pressure switch.

Indication LED ZSE80(F)/ISE80(H) Black OUT1 button (UP) OUT2 White ISE80: 0.050 MPa ZSE80: 5.0 kPa ZSE80F: 5.0 kPa ISE80H: 0.100 MPa Blue DC(-) button (SET) Hysteresis Chattering can be prevented by setting hysteresis. Thank you for purchasing an SMC ZSE80(F)/ISE80(H) Series Digital Pressure Switch.

1 V7 LEFS 32 200 R H B B 3 M2 S r Motor type e Motor mounting position w Size q Accuracy Nil Basic type H High precision type 25 32 40 Nil In-line R Right side parallel L Left side parallel Symbol Type Output [W] Size Compatible driver V6 AC servo motor (Absolute encoder) 100 25 LECYM2-V5/LECYU2-V5 V7 200 32 LECYM2-V7/LECYU2-V7 V8 400 40 LECYM2-V8/LECYU2-V8 u Motor option t Lead [mm] i Cable

External pilot Solenoid Orifice size (mm) Model Threaded Note) Flange Av x 10-6 m2 VNC1-6A VNC1-8A VNC1-10A VNC24-10A VNC2-10A VNC24-15A VNC2-15A VNC34-20A VNC3-20A VNC44-25A VNC4-25A VNC54-32A VNC5-32A VNC54-32F VNC5-32F VNC64-40A VNC6-40A VNC64-40F VNC6-40F VNC74-50A VNC7-50A VNC74-50F VNC7-50F 1 8 1 4 30 32 36 95 120 110 140 170 260 220 370 400 560 400 560 630 820 720 960 990 1500 1000

(Individual exhaust for Pilot valve) L LN Connector (0.3 m) Connector (W/o lead wire) LO Without connector M Connector (0.3 m) MN Connector (W/o lead wire) MO Without connector G Grommet (0.3 m) H Grommet (0.6 m) Rated voltage 1 3 100 VAC 110 VAC 5 24 VDC 6 12 VDC V Pilot valve DC: 1 W (With indicator light: 1.05 W) 24 VDC and 12 VDC are applicable to 0.45 W.

This is not a clean room series product. 4 MACM Series Dimensions W (Workpiece loadable range) 4 x D At maximum offset (A + 2 x S) S F DB DA C X114 X115, X116 U B W A H T H Q PB E PA PD P (Unlocking port) PE P (Locking port) P (Relief port) (Option V only) MACM4, MACM6 MACM2, MACM10 PC PC PC PC PE P (Relief port) (Option V only) PD [mm] Dimensions Model A B C D DA DB E F H P PA PB PC PD