VAC 50/60 Hz 220 VAC 50/60 Hz 24 VDC 12 VDC 240 VAC 50/60 Hz Other VC 100 VAC 50/60 Hz 200 VAC 50/60 Hz 110 VAC 50/60 Hz 220 VAC 50/60 Hz 24 VDC 12 VDC 240 VAC 50/60 Hz Other Nil S Z None With surge voltage suppressor With light/surge voltage suppressor With indicator light Option VDW L Light/Surge voltage suppressor Nil Z VQ Except 12 VDC, 240 VAC, other voltages.
Insulation type Electrical entry Electrical option Class B G C D, T S Note) S L, Z 1 (100 V) 2 (200 V) 3 (110 V) 4 (220 V) 7 (240 V) 8 (48 V) 5 (24 V) 6 (12 V) AC DC Note) Surge voltage suppressor is attached in the middle of a lead wire. 17-3-72 3 The VX series will be revised shortly.
VN Rated voltage 1 2 3 4 5 6 7 8 9 Solenoid valve option Nil Standard 100 VAC 50/60 Hz 200 VAC 50/60 Hz 110 VAC 50/60 Hz 220 VAC 50/60 Hz 24 VDC 12 VDC 240 VAC 50/60 Hz 48 VAC 50/60 Hz Other (Please contact SMC separately.) LVC Select an option mark in page 17-3-10 by Applicable Fluids Check List for special fluids outside of the standard.
VX3 Rated voltage 1 2 3 4 5 6 7 8 9 Valve/Body 0 Normally cosed/Single unit 100 VAC 50/60 Hz 200 VAC 50/60 Hz 110 VAC 50/60 Hz 220 VAC 50/60 Hz 24 VDC 12 VDC 240 VAC 50/60 Hz 48 VAC 50/60 Hz Other (Please contact SMC separately.) VXA VN Solenoid valve option Nil Standard LVC Select an option mark in page 17-3-11 by Applicable Fluids Check List for special fluids outside of the standard.
In case of 110/220VAC, VDW10 is 3W and VDW20/30 is 3.5W. Note 4) Vibration resistance No malfunction when tested with one sweep of 5 to 200Hz in the axial direction and at a right angle to the armature, in both energized and deenergized states.
Matching the ejector to the vacuum circuit Refer to technical data on page 13-110 to 19 for precautions on the vacuum circuit.
VAC (50/60 Hz) DC: 1 W (With light: 1.2 W), 100 VAC: 1.4 W (1.45 W), 110 VAC: 1.45 W (1.5 W) Air Operated Valve Specifications Refer to page 13-4-11 for dimensions.
Vacuum pressure switch suction filter Voltage (Refer to Table (1).) 1 2 3 4 5 6 100 V AC 200 V AC 110 V AC 220 V AC 24 V DC 12 V DC Suction filter only 1 NPN output and analog output, suction filter 2 NPN outputs, suction filter 1 PNP output and analog output, suction filter 2 PNP outputs, suction filter F D31 D32 D51 Electrical entry D52 L plug connector, With 0.3 m lead wire With light/
fl 110+559120+559 Differenl 1 5 90 100 1 1 0 Same 90 100 1 1 0 Ditterent 15+5d!
0.043 30 32 CC 32 38 D 7.6 12 16.6 21.6 26.4 33.6 41.6 52.4 65.4 E 4 1.5 2 2 2 2 3 8 8 F 8 9 10 13 13 16 16 2 2 G 5 5 5.5 7.5 7.5 8 11 14 14 H 13.5 12.5 13 20 20.5 22 29 33 33 I 28 34 40 50 58 72 J 4.5 4.5 6 6 8 8 10 12 12 K 5 4 11 8 10 15 16 25 26 N 9.5 11 11 18 18.5 20 26 25 25 Q NN S 62 63 83 106 111 124 150 176 188 V A 4 4 4 8 8 8 10 T C 8 14 14 26 32 32 41 L 35 38 57 66 70 80 92 110
Note) Air flow capacity (scfm [ANR]) Applicable air compressor (kW) 50 Hz Model Power supply voltage (Frequency) Port size 60 Hz IDF1E 3.53 4.24 0.75 Single-phase 100 VAC (50 Hz) Single-phase 100/110 VAC (60 Hz) IDF2E 7.06 8.30 1.5 Rc3/8 IDF3E 11.3 13.1 2.2 IDF4E 18.4 20.1 3.7 Rc1/2 Single-phase 100/200 VAC (50 Hz) IDF6E 26.5 29.0 5.5 Single-phase 100/110 VAC, 200/220 VAC (60 Hz) IDF8E 43.1
Solenoid valve model VO307-1 0.3 to 0.7 MPa Valve unit Small flow Large flow Solenoid valve type Stop valve Skip valve Valve type Nominal size (mm) 63, 100 100, 160 External pilot pressure N.O No mark 100, 200, 110, 220, 240 No mark N.O AC (50/60 Hz) Coil rated voltage (V) 24, 12 Valve opens when solenoid valve conducts electricity.
W Fulcrum L Front matter 5 Series CKZ3 Model Selection Model Selection CKZ3N North American Type Made to Order European Type CKZ3T 3 Clamp arm 50 63 300 150 280 140 Distance from pivot point L(mm) Distance from pivot point L(mm) 260 130 240 120 220 110 200 100 180 90 160 80 140 70 120 60 100 0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 6.0 6.5 7.0 7.5 8.0 50 0 0.5 1.0 1.5 2.0 2.5 3.0 3.5
MY Standard Stroke CY (mm) MG Manufacturable stroke range Model Standard strokes CXSJ6 CXSJ10 CXSJ15 CXSJ20, 25, 32 60 to 100 10, 20, 30, 40, 50 CX 80 to 150 10, 20, 30, 40, 50, 75 110 to 150 D10, 20, 30, 40, 50, 75, 100 110 to 200 Strokes beyond the standard stroke range are available as a special order.
VK300-82-2-01 VK300-82-2-03 110 VAC 110V 200 VAC 200V VK300-82-2-02 VK300-82-2-04 220 VAC 220V VK300-82-2-07 VK300-82-4-51 VK300-82-4-06 VK300-82-3-05 VK300-82-3-53 240 VAC 240V 6 VDC 6V 12 VDC 12V 24 VDC 24VD 48 VDC 48VD 3-2-11
(Values at the initial period) Solenoid Specifications Electrical entry Grommet (G), DIN terminal (D) 100, 110, 200, 220, 240 12, 24 10% of rated voltage 9.5 VA/50 Hz, 8 VA/60 Hz 7 VA/50 Hz, 5 VA/60 Hz 3.5 VA/50 Hz, 3.3 VA/60 Hz 3 VA/50 Hz, 2.8 VA/60 Hz 4 W (Standard), 2 W (Low power consumption type) 4.3 W (Standard), 2.3 W (Low power consumption type) Varistor Diode (Varistor for 12 VDC
Port size (P, A and B port) Rated voltage M5 01 M5 x 0.8 1 2 3 4 5 6 7 100 VAC, 50/60 Hz 200 VAC, 50/60 Hz 110 VAC, 50/60 Hz 220 VAC, 50/60 Hz 1 8 R1, R2: M5 Option 24 VDC 12 VDC Nil None With bracket (Not assembled) 240 VAC, 50/60 Hz For other rated voltages, please consult with SMC. F Option Part No. Description Part no.
1: VN1-A16 (with thread) Valve sizes 2 to 4: VN-16 Nil F N T A B C NBR seals FKM seals EPR seals Nil B Note) None With bracket Refer to Table (1) for availability. 2 0 1 A VNA Air operated 15A 2 to 4 External pilot solenoid 2 VNA 1 1 A 15A 1 T CE-compliant Nil Q CE-compliant Note) CE-compliant: For D or DZ only Manual override Rated voltage Valve size Valve type Port size 3 Note 2) 2 1 110
(mm) Symbol 1 2 3 Note 2) Port size Rc 100 VAC 50/60 Hz 200 VAC 50/60 Hz 110 VAC 50/60 Hz 220 VAC 50/60 Hz 24 VDC 12 VDC 240 VAC 50/60 Hz 1 2 3 Note 1) 4 Symbol Nil: Non-locking push type N.C. 1 MPa N.C. 0.5 MPa N.O. 1 MPa C.O. 1 MPa Note) 4 Note 2) A: Non-locking push type A (projecting) 1 6A 8A 10A 1 8 1 4 3 8 5 6 Note 2) 7 Valve size 1 to 4 7 Note 2) 11 15 11 10A 3 8 B: Slotted locking
VN1-A16 (with thread) Valve sizes 2 to 4: VN-16 2 to 4 2 0 1 A VNC 15A (Except valve size 8, 9) Air operated External pilot solenoid 2 VNC 15A 1 1 1 A T CE-compliant Nil Q CE-compliant Note) Electrical entry: D or DZ only Manual override Valve size Valve type Port size Rated voltage Nil: Non-locking push type Nil Air operated Symbol Orifice diameter (mm) Symbol Port size Rc 1 2 4 3 2 1 110