10 10 54 32 26 11 22 20 44 16 11 15 6 27 71.5 60 42 22 21 150.5 8 M8 x 1.25 25 to 800 25 to 650 50 35 12 13 10 59 40 27 11 27 21 52 20 10 17 9 32 80.5 70 46 24 28.5 162.5 11 M8 x 1.25 25 to 800 25 to 650 60 35 15 18 10 67 40 26 27 23 64 20 13 17 9 32 98.5 85 48.5 24 28.5 174 11 M10 x 1.25 13.5 25 to 750 25 to 600 70 40 17 23 14 72 52 30 32 23 78 25 15 21 11 37 117.5 102 55 26.5 36 189 13

10 10 63 63 63 50 50 50 40 1 1 1 25 20 25 20 40 32 40 32 32 [Example w] 25 20 0.3 0.3 0.1 70 100 1000 70 100 1000 70 100 1000 Stroke (mm) Stroke (mm) Stroke (mm) 2.

(Refer to 2.3.1 Setting of contact input signal type and form) If an input from an external switch is detected, it can be generated as an alarm.Options to select continuous monitoring or monitoring during operation are available. Also, the detection start time after the start of operation and the detection end time can be set.

Outlet air atmospheric pressure dew point C P1 = 0.5MPa P1 = 0.5MPa 10 10 20 20 P1 = 0.7MPa P1 = 0.7MPa 30 30 40 40 0 40 80 120 160 20 40 60 80 0 Outlet air flow rate l/min (ANR) Outlet air flow rate l/min (ANR) IDG20 IDG30 P1 = 0.3MPa P1 = 0.3MPa 0 0 Outlet air atmospheric pressure dew point C Outlet air atmospheric pressure dew point C P1 = 0.5MPa 10 P1 = 0.5MPa 10 P1 = 0.7MPa 20 20 P1

MPa 5.0 MPa Rated pressure range 2.0 MPa 1.0 MPa 1.6 MPa 1.0 MPa Withstand pressure 1.5 MPa 2.4 MPa 3.0 MPa 5.0 MPa 12.5 MPa 30 MPa Power supply voltage When used as a switch output device 12 to 24 VDC 10% with 10% voltage ripple or less When used as an IO-Link device 18 to 30 VDC, including ripple (p-p) 10% Temperature characteristics 2% F.S. (25C standard) 3% F .S.

Displays nothing Analog output free range function This function allows a flow that generates an output of 5 V (or 10 V when 0 to 10 V is selected) or 20 mA to be changed. The value can be changed between 10% of the maximum value of the rated flow and the maximum value of the display range.

10-9 1.3 x 10-8 Kalrez 1.3 x 10-10 (FKM) Q1 R1 R2 R3 S1 T1 4079 SS592 SS630 SSE38 1232-70 Note 1) Values at ambient temperatures, excluding gas permeation.

Name Alarm flag 1 Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Name Alarm flag 2 Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Name Alarm flag 3 Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Name Alarm flag 4 Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Name Alarm flag 5 Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Bit Name Explanation 0 Low tank fluid level 1 CH1 abnormal high circulating fluid temp. 2 Reservation

A2 10 11 12 17 Model A1 6 10 10 11 MXF8 MXF12 MXF16 MXF20 A3 6 10 10 11 A4 21 23 28 34 A5 21 23 28 34 A6 10 11 12 17 Graph (2) Allowable Moment Coefficient: Note) Note) MXF8 MXF12 MXF16 MXF20 1.0 Allowable Moment Coefficient: Note) 16 mm for MXF8-10 only. 0.7 Stroke (mm) Table (4) Maximum Allowable Moment: Mmax (Nm) 0.5 0.4 Model 10 0.56 100 18.27 75 7.96 13.70 50 3.34 5.69 9.14 30 0.98

Purchasing order is available in units of 10 pieces.

Consider an external guide, etc., for safety design. 1. Be careful not to drop or hit the product to avoid scratches and dents. Even slight deformation of the suction surface can decrease product performance. 2. When installing the product, tighten it with an appropriate tightening torque.

Note 6) Product other than the option R is not equipped with an earth leakage breaker. Please purchase an appropriate earth leakage breaker separately.

Reference Heavy duty auto drain 6.3 Outer dimensions [IDF100F-30-W] Ball valve (O.D.10, Length approx. 2m) is also available.)

0.8 0.7 0.7 0.7 0.6 0.6 0.6 0.5 0.5 0.5 0.4 0.4 0.4 0.3 0.3 0.3 0.2 0.2 0.2 0.1 0.1 0.1 VY130-5 VY140-5 VY150-5 0 1 2 3 4 5 0 1 2 3 4 5 0 1 2 3 4 5 V V V VY130-6 VY140-6 VY150-6 1 1 1 0 2.5 5 7.5 10 0 2.5 5 7.5 10 0 2.5 5 7.5 10 V V V VY130-7 VY140-7 VY150-7 mA mA mA 4 0 8 12 16 20 4 0 8 12 16 20 4 0 8 12 16 20 2 2 2 VY130-8 0 5 10 15 20 VY140-8 0 5 10 15 20 VY150-8 0 5 10 15 20 3 3 3 mA

Applicable shaft type: W (mm) L2 Y Size (mm) 10 X L1 3 to 8 5 ( 8 Y) to (Y 1) Size 10 15 3 to 14 9 (14 X) to (X 1) 3 to 9 6 ( 9 Y) to (Y 1.5) Y = L1 = 15 20 5.5 to 18 10 (18 X) to (X 1.5) 3 to 10 7 (10 Y) to (Y 1.5) L2 = 20 30 7 to 20 10 (20 X) to (X 1.5) 5 to 13 8 ( 13 Y) to ( Y 2) X = 30 40 7 to 22 10 (22 X) to (X 1.5) 7 to 15 9 (15 Y) to (Y 4.5) Symbol: A11 The long shaft can be further

Refer to the Auto Switches Precautions (Web Catalog) if using with an auto switch. 10. Risk to people with pacemakers The product has a magnet inside. It may interfere with the use of an electronic equipment such as a pacemaker. People with pacemakers should stay away from the magnet gripper or take safety measures to block the magnetic force. Caution 1.

Installation When installing the product, mount it on a flat surface with no inclination. 10. If an external tank is used, the circulating fluid may spill out from the internal tank lid depending on where the external tank is installed.

Description Material 25 32 40 NBR Rod seal HDU-8 HDU-10 HDU-12L HDU-14 !

Air Piping Compressor Air Delivery Caution Caution HAA HAW IDFA55E, 75E Compressed air inlet Compressed air outlet Use an air compressor with an air delivery of 100 L/min or larger with the IDFA3E to 75E series.

This allows reading and monitoring the contact signal from an external switch. When inputting an external switch signal to the contact input, select External Switch (external switch signal) for the type of contact input signal. (Refer to 2.3.1 Setting of contact input signal type and form) If an input from an external switch is detected, it can be generated as an alarm.