L O L G H F K J E D I A B C 2-4.5 A B C D E F G H I J K L Model 4 ZFC100-04 6 ZFC100-06 53.2 9.1 30 14.1 10 18 11.6 19.5 23 20 29 5/32" ZFC101-03 1/4" ZFC101-07 6 ZFC200-06 8 ZFC200-08 67 15.5 34 17.5 14 22 15.6 23.1 27 24 35 1/4" ZFC201-07 5/16" ZFC201-09 Element Replacement Element replacement procedure 1) Stop operation and reduce the filter's internal pressure to atmosphere. 2) Turn cover
Table 1 Display Real-time flow rate l/min Accumulated flow l, m, m x 10 ft, ft x 10, ft x 10 CFM Note 1) For the type with unit switching function [The type without the unit switching function will have a fixed SI unit (l/min, or l, m or m x 10)]. 14 For Air Digital Flow Switch Series PFA 4. Output Specification Selection Mode For For Flow rate setting SET SET Press the SET button.
508 E R350 R440 G 93 129 H 302 327 A 791 916 A 823 906 A 835 934 15 32 15 32 15 32 I 10 15 J 6 7 X 244 to 254 262 to 279 Y Note 2) I 10 15 J 6 7 X 233 to 244 224 to 241 Y Note 2) J 6 7 X 240 to 251 236 to 253 Y Note 2) H 298 339 H 323 352 I 10 15 15 32 15 32 15 32 589 to 614 633 to 673 564 to 589 542 to 581 579 to 605 571 to 610 MF -90 15 32 A G D Note 1) F D Note 1) D Note 1) F F Y C C
Series REAL Size: 10, 15, 20, 25, 32, 40 To ensure a permanent path. When smoother operation is required, even with an eccentric load. Stable operation is possible even with an eccentric load, through the use of a ball bushing. Series REAH Size: 10, 15, 20, 25, 32 The use of a linear guide makes possible a large load, large moment and high precision.
set unit Note 1) Accumulated pulse flow rate exchange value (Pulse width: 50 ms) Note 1) 0.1 l/pulse 0.5 l/pulse 1 l/pulse 2 l/pulse 5 l/pulse l/min, CFM x 10-2 l, ft3 x 10-2 l/min, CFM x 10-1 l, ft3 x 10-1 Display units Real-time flow rate Accumulated flow Note 1, 2) 0 to 9 l, 0 to 9 ft3 x 10-2 0 to 9 l, 0 to 9 ft3 x 10-1 Accumulated flow range Note 1) Power supply voltage Current consumption
*10 *10 *10 *10 *10 *7 For pipe thread type: NPT.
NPT ZQ 06 3/4 10 1 ZF ZP Nil 2 6 J R Option/Combinations Combination available Combination not available ZCU Option Symbol Drain cock Nil AMJ Metal bow 2 Nylon bowl Misc. 6 Drain guide J Flow: Right Left R Model Model AMJ5000 AMJ4000 AMJ3000 Recommended flow rate (l/min(ANR)) 500 300 200 Port size (Nominal size B) 3/4, 1 3/8, 1/2 1/4, 3/8 Weight (kg) 1.1 0.6 0.3 Specifications Fluid Air
Model CYP15 CYP32 Series Throttle valve 10-AS2200-01-X214 Elbow type 10-AS1200-M5-X216 Metal body piping type 10-AS2000-01-X209 In-line type 10-AS1000-M5-X214 10-AS2201F-01-04-X214 10-AS1201F-M5-04-X214 Elbow type (throttle valve) 10-AS2201F-01-06-X214 10-AS1201F-M5-06-X214 10-AS2201F-01-06-X214 Operation 10-AS2301F-01-04-X214 10-AS1301F-M5-04-X214 Resin body with One-touch fitting Caution
An accumulation of undetected faults can cause loss of safety function. Category 4 It has redundancy so there is no loss of safety function with a single failure. The safety function must be checked before each use. An accumulation of undetected faults does not affect the safety function. (Higher DC and MTTFd than Category 3.)
A AL B B1 C D E F G H H1 J K KA M MM N P S ZZ 32 Up to 300 22 19.5 42 17 31 10 24 8 9 38 6 M5 x 0.8 5.5 8 8 M10 x 1.25 18 1/8 63 109 40 Up to 300 24 21 48 22 37 14 32 9 9 44 8 M5 x 0.8 8 12 8 M14 x 1.5 18 1/8 62 114 45 Up to 300 24 21 52 22 41 14 32 9 9 44 8 M5 x 0.8 8 12 8 M14 x 1.5 18 1/8 62 114 50 Up to 400 35 32 60 27 45 18 38 10 9 55 11 M6 x 1 7 16 11 M18 x 1.5 18 1/8 63 129 56 Up to
depth 2 2.5 Q QL 11-/22-MXPJ6-10 4 x M3 x 0.5 depth 3 F (mm) E F H J M Q QL S Z Model 23 25 38 27 37 28 8 5 44 11-/22-MXPJ6-51 30 35 53 42 47 37 11 10 59 11-/22-MXPJ6-10 833 Air Slide Table MXP/MXPJ6 1122Dimensions: MXP6 1122Air Preparation Equipment Pressure Control Equipment Flow Control Equipment Pressure Switches/ Pressure Sensors Directional Control Valves Air Grippers Modular F.
2-M3 x 0.5 (Plug: M-3P) 6 (fitting seat surface dimension) 170.05 M3 x 0.5 Vacuum suction port Stroke: S M 1 Mounting base side B D Piping port 2-M3 x 0.5 A 5 5.5 A 3.2 J 2.4 Z Section AA 3.5 Depth 2 2.5 +0.030 0 7 +0.030 0 Depth 2 2.5 Q QL 11-/22-MXPJ6-10 4M3 x 0.5 depth 3 F (mm) E F H J M Q QL S Z Model 23 25 38 27 37 28 8 5 44 11-/22-MXPJ6-51 30 35 53 42 47 37 11 10 59 11-/22-MXPJ6-10
) Note 10) Note 10) Note 10) Note 10) Note 10) use pressure within the specification range.
TB W Counter bore depth TC Inner cover holding screw Note) (mm) E 4 6 J M6 x 1 M10 x 1.5 LD 5.6 9.2 L 67 90 K 21 20 JK 10 12 HP 44 73.5 HL 37.6 63.3 HI 23 39 HA 23 39 H 45 75 G 10 9 F 12.5 25 EK 4 6 ED 9.5 13 C 6.4 10.2 B 10.5 16 A 8 12 Model CYV15 CYV32 +0.030 H9 0 +0.030 H9 0 Z 132 165 Y 2.5 3.5 W 69 115 TC 0.5 0.5 TB 15 22 TA 20 22.5 T 30 34 R 45 79.5 QW 48 83 Q 112 147 PC 10 12 PB 60
15 20 25 32 10, 20, 30, 40, 50 Vacuum suction type Relief type M5 x 0.8 10, 20, 30, 40, 50, 75, 100 1/8 Double acting (Both sides) Non-lube 10-/12-/21-CXS6 6 single rod 10-/12-/21-CXS10 10-/12-/21-CXS15 10-/12-/21-CXS20 10-/12-/21-CXS25 10-/12-/21-CXS32 10, 20, 30, 40, 50 10 15 20 25 32 M5 x 0.8 10, 20, 30, 40, 50, 75, 100 1/8 Specifications Suction flow rate of vacuum suction type (Reference
Table 1 Moment of inertia Size Allowable kinetic energy (J) 10 0.00015 15 0.00025 20 0.0004 30 0.015 40 0.03 How to calculate the load energy E : Kinetic energy (J) I : Moment of inertia (kg m Speed (rad/s) : Rotation angle (rad) 1803.14 rad t : Rotation time (s) 1 E = I 2 2 2 = t Table 2 Safety operable rotation time adjustment range Size Rotation time ( s / 90) 10 0.03 to 0.5 15
A One-touch fittings KP series B Dimensions (mm) Model A B C SFE4G 6 68.5 16.5 SFE5H 8 79 20.5 SFE7J 10 89 24 Bracket SFE-BR3 14 5 3.4 (15.5) 12.5 5.4 5.4 14 24 (20) SFE-BR4/5/7 B C (J) H D (F) G A E E Dimensions (mm) Model A B C D E F G H J SFE-BR4 30 16 7 4.5 7.5 (24.5) 17 15.5 (19.5) SFE-BR5 30 10 8.2 4.5 8.1 (29) 20 18 (23) SFE-BR7 34 14 7.35 4.5 9.8 (35) 24 20 (27.3) ( ): Reference dimensions
l (mm) l 300 200 300 MGTL80 P = 0.5MPa m 200 MGTM80 100 P = 0.5MPa Load weight m(kg) Load weight m(kg) 40 50 100 Larger than 75st 50st 25st Larger than 50st 30 20 50 40 25, 50st 10 30 5 4 3 2 20 10 20 30 40 50 100 200 300 1 1 2 3 4 5 10 20 304050 100 200300400 Eccentric distance l (mm) 10 400 Eccentric distance l (mm) MGTL100 300 200 300 MGTM100 200 P = 0.5MPa 100 P = 0.5MPa Larger than