SMC Corporation of America
Elite Part Number Search
Search Results "HRS018-AN-20-B"

Method of Mounting Two Auto Switches at the Stroke End of a Cylinder for Strokes Less Than 20 mm Auto switch model Applicable strokes 15 mm stroke 20 mm stroke 15 6 3 A 6 A 20 0.5 D-M9m(V) D-M9mW(V) D-M9mA(V) 0.5 3 6 B 6 B The correct mounting position of the D-M9 is 3 mm from the end face of the switch holder (dimensions A and B).

Refer to the Made to Order Specifications on page 20.

Air-To-Electric Signal Conversion Q: Is it possible to convert an air signal into an electrical signal? A: air-to-electric switches, MPE-BZ or MPE-BZE (includes enclosure), will turn an air signal into an electrical signal, which can be wired either normally open or closed.

Air-To-Electric Signal Conversion Q: Is it possible to convert an air signal into an electrical signal? A: air-to-electric switches, MPE-BZ or MPE-BZE (includes enclosure), will turn an air signal into an electrical signal, which can be wired either normally open or closed.

Method Data Bore size (mm) 20, 25 32, 40, 50, 63, 80, 100 Stroke range (mm) 1 to 50 1 to 100 Stroke range Part no.: CLQB40-47D-B A 3 mm spacer is installed in standard cylinder CLQB40-50D-B. B dimension is 79.5 mm.

Install an air filter. Install an air filter at the upstream side of valve. Select an air filter with a filtration degree of 5 m or finer. 8. Interference in oval type release button The following models cannot be used if a box wrench or socket wrench is used. 2. Install an aftercooler, air dryer or water separator, etc.

Round plate (Including column) Position of rotational axis: Through the center (A) Number of axis teeth =a (B) 1. Find the moment of inertia I for the rotation of shaft (B). B r 2. I is converted to the rotation of the shaft (A). B 2 r I = m2 2 b a I I = A B Number of teeth =b 5.

H9) TL JJ US TA TD G L UW TB TC M N b l 90 180 90 180 90 180 3 29 104 130 122 153 20 0 0.03 1 15 59 24.5 8 11 9.6 11.5 4 13.5 27 4 4 2.5 74 20 M5 x 0.8 depth 6 0 0.03 30 2 18 65 27 10 13 11.4 13.5 19 36 4 4 2.5 83 4 33 4 20 40 139 177 5 37 5 M6 x 1 depth 7 0 0.03 93 11 20 15 14 17 25 73 32.5 2 20 5 3.5 39.5 5 Dimension AU does not indicate the dimension when shipped because of the adjustment

Analog Output Flow/Analog output Output A B C Voltage output 1 V 1.1 V 5 V Current output 4 mA 4.4 mA 20 mA C Model Rated flow [L/min] Minimum Maximum LFE1 0.5 20 LFE2 2.5 100 LFE3 5 200 B A Outside the range 0 Min.

(mm) D-M9 V D-F9 WV Auto switch model D-A9 V Symbol A B Hs A B Hs 20 25 32 40 50 63 24 26 29 32 38 43 9.5 11.5 13 13 19.5 21.5 15.5 15.5 19 20 13.5 15.5 22 24 27 30 36 41 11.5 11.5 15 16 9.5 11.5 5.5 7.5 9 9 15.5 17.5 Bore size (mm) 9 ISO Standards [ISO/21287] Compact Cylinder Series C55 The Number of Surfaces and Grooves Where an Auto Switch Can Be Mounted (As Direct Mounting) The number

143 Deflection Data 145 Part Number Designations 100 F N 1 1 B G LJ1 10 H W X10 Guide type High rigidity direct acting guide H X10 Non-standard motor Series Series 10 Series 20 Series 30 Limit switch 10 20 30 Cable entry direction None B contact specification 2 pcs.

Applicable dryer Weight (g) A B AMH A IDF-FL209 IDF-FL202 IDF-FL203 IDF-FL204 IDF-FL205 IDF-FL206 IDF-FL207 IDF-FL208 IDF-FL213 IDF-FL214 IDFA3E IDFA4E IDFA6E IDFA8E IDFA11E IDFA15E1 IDFA22E IDFA37E IDFA55E IDFA75E 220 310 375 340 375 440 420 550 720 610 240 35 45 55 70 75 120 100 140 175 190 (20) (20) AME 195 265 B AMF 370 315 365 400 560 ZFC SF (10) SFD (IDF-FL209) (IDF-FL202 to 208, 213

CKQ CLKQ B B B B B B A 14 49 B B A 14 49 B A 14 49 B A 7 42 A 10 45 A 11.5 46.5 A 11 46 19 or more 17 or more 33 or more 27 or more 28 or more 27 or more 22 or more 30 or more 22 or more 17 or more 54 or more 52 or more Auto Switch Mounting Height Atmosphere General use Mounting Rail mounting Rail mounting Welding Direct mounting D-A7 D-A80 D-A7H D-A80H D-F7BAL D-F7W D-J79W D-F7NTL D-F79F

1Bore size , VV5FR5-01FUStation 1Bore size Light/Surge voltage suppressor 235.5 204 (72) 60 11 4 60 U side Manual override (Non-locking) 6 [2] 21 R5.5 B B B B A A A A n B B B A A A B B B B A A A A 3 L1 L2 2 11 11 71.5 (Pitch) P = 51 Pitch P = 51 71.5 1 Stations 2n-Rc 1/2, 3/4 (A, B port) 20 24 [23] 105.5 176.5 209 Plug assembly: VVZS3000-21A(Option: Refer to page 3-5-8.) 2n-Rc 1/2 58 28 70

(Voltage input: 1 to 5 V/Current input: 4 to 20 mA) Pressure switch/Flow switch can be displayed. B A is displayed for 1 V (or 4 mA). B is displayed for 5 V (or 20 mA). The range can be set as required. Display Select NPN or PNP A NPN PNP Voltage input 1 V 5 V Current input 4 mA 20 mA Analog output of 0 to 10 V is also available.

RE A B Mounting bracket nut Unit holding tie-rod Bore size (mm) Nut Width across flats REC Socket Width across flats Socket JIS B 4636 2 point angle socket 10 10 40 JIS B 1181 Class 3 M8 x 1.25 JIS B 4636 CX 13 2 point angle socket 13 JIS B 4636 2 point angle socket 13 50 13 CY JIS B 4636 2 point angle socket 13 JIS B 4636 JIS B 1181 Class 3 M10 x 1.25 63 17 13 2 point angle socket 17 MQQ

No 3000G 45-089 Stripper for round cable (2.0) can be used for a 2-wire type cable. 181 Applicable auto switch list Cylinder CDQSX CDBM2 CDM2X CDQ2X CDQS CDM2 CDG1 CDQ2 CDA2 CXSJ CDJ2 MGP MXQ Cylinder series MGF MXP MXS CDU REC CXS CYP CUJ 40/63/100 32 to 100 20 to 40 20 to 40 20 to 63 40 to 63 12 to 25 20 to 40 12 to 63 12 to 25 32 to 63 20 to 40 80/100 6 to 10 6 to 25 6 to 32 6 to 16 6

x 103 M Yaw moment M3 = m x g x (L + A) x 103 M Roll moment M2 = m x g x (L + B) x 103 (mm) Model CYP15 CYP32 A 16.5 27.0 B 25.5 48.0 L B L B L A M1, 2, 3 : Moment [Nm] m : Load mass [kg] L : Distance to load center of gravity [mm] A, B : Distance to guide shaft [mm] g : Gravitational acceleration [9.8m/s] M2 M1 M3 m x g m x g Guide shaft mounting surface m x g Guide central axis Cylinder