Auto switch mounting surface Bore size (mm) 20 32, 40, 50 63, 80, 100 Port side Port side CHQ CHQ CHK C A C A CHN CHM B B CHS Auto switch mounting surface Auto switch mounting surface Auto switch mounting surface Auto switch models Auto switch mounting rail surface only A, B, C Port, A, B, C sides Port side CH2 qBQ-1 wBQ2-012 Two types of auto switch mounting bracket are used as a set. qBQ
Description B VNH1 VNH2 VNH3 VNH4 VNH1-16 VNH2-16 VNH3-16 VNH4-16 Bracket (with bolt and washer) 4.2-30 VNH Specifications 3 port valve 2 port valve A B A B VNH311 20A A B VNH411 25A A B VNH113 10A A B VNH213 15A A B VNH313 20A A B VNH413 25A A B VNH133 10A A B VNH233 15A A B VNH333 20A A B VNH433 25A A B VNH111 10A VNH211 15A Model Operating fluid pressure Fluid Operation 0 to 7.0MPa 0 to
A C MTS D-F9W, D-M9 D-A93 D-A90, D-A96 D-M9V, D-F9WV Bore size (mm) CXSJ15 to 32 B D A 15.5 25.5 31.5 39 40 49 D 9.5 7 0 3 5 5.5 C 9.5 19.5 25.5 33 34 43 B 6 9 11 11.5 B 0.5 3 10 13 15 15.5 A 15.5 25.5 31.5 39 40 49 A 19.5 29.5 35.5 43 44 53 C 11.5 21.5 27.5 35 36 45 D 5.5 3 4 7 9 9.5 D 8 5.5 1.5 4.5 6.5 7 B 6 9 11 11.5 B 0.5 3 10 13 15 15.5 C 13.5 23.5 29.5 37 38 47 C 11 21 27 34.5 35.5
Working principle A + A A Series CXS 6, 10, 15, 20, 25, 32 Reverse mounting Piston seal A A A R H R H 1. When the piston is retracting, air is exhausted through both A and A until piston seal H passes air passage A. 2. After piston seal H has passed air passage A, air is exhausted only through A.
center 3 position exhaust center 3 position closed center 3 position pressure center (1) 3 position exhaust center 3 position closed center (A) 4 (B) 2 (A) 4 (B) 2 (A) 4 (B) 2 (A) 4 (B) 2 (A) 4 (B) 2 (A) 4 (B) 2 5 (R1) 1 (P) 3 (R2) 5 (R1) 1 (P) 3 (R2) 5 (R1) 1 (P) 3 (R2) 5 (R1) 1 (P) 3 (R2) 5 (R1) 1 (P) 3 (R2) 5 (R1) 1 (P) 3 (R2) Note 1) Except VQZ1000 and metal seal.
D-G39A D-K39A D-A44A D-H7lW D-H7BAL D-H7lF D-C73C D-C80C D-B5 D-B6 D-H7l D-H7C D-B59W D-G5NTL Bore 20 25 32 40 A B 5(3) 5(3) 6(4) 11 A 6(4) 6(4) 7(5) 12 B 0(0) 0(0) 0.5(0) 5.5 A 0.5(0) 0.5(0) 1.5(0) 6.5 B 3(1) 3(1) 4(2) 9 A 4(2) 4(2) 5(3) 10 Hs 69.5 72 75.5 79.5 B 6(4) 6(4) 7(5) 12 Hs 60 62.5 66 70 A 7(5) 7(5) 8(6) 13 Hs 25 27.5 31 35 B 0(0) 0(0) 1(0) 6 Hs 22.5 25 28.5 32.5 A 1(0) 1(0) 2
: 10 One-touch fitting C12 : 12 One-touch fitting L2 6.5 5.5 108 L1 Manual override Indicator light 65.5 P=25 A A A B A B A B A B A B 21 21 63 9 A A A A A A A 143 163 66 41.5 9 B B B B B SI unit Input block 10 n 1 2 3 4 5 6 7 Stations D-side 8 U-side Formulas L1 = 25n + 106 (Maximum 16 single wiring stations) L2: For one input block.
Fig. 4-1 Position of the earth leakage breaker (This drawing is [HRS150-A-20-B].) 2. Mount the front panel. 3.
S Dimensions R V Head side flange style (G): CG5GNS GA GB FT Width across flats KA 2-Rc P H1 Width across flats B1 D I RE A B AL A MM Width across flats NA K REC C0.1 8-J 4-FD M S + Stroke ZZ + Stroke H FX0.15 B CX CY Stroke range A Bore size (mm) AL B1 B C D FX FD FT GA GB H H1 I J K KA M MM NA P S ZZ 20 MQQ M Up to 200 18 15.5 13 50 16.5 8 36 5.5 6 18 12 35 5 31 M4 x 0.7 5 6 3 M8 x 1.25
S Dimensions R V Head side flange style (G): CG5GNS GA GB FT Width across flats KA 2-Rc P H1 Width across flats B1 D I RE A B AL A MM Width across flats NA K REC C0.1 8-J 4-FD M S + Stroke ZZ + Stroke H FX0.15 B CX CY Stroke range A Bore size (mm) AL B1 B C D FX FD FT GA GB H H1 I J K KA M MM NA P S ZZ 20 MQQ M Up to 200 18 15.5 13 50 16.5 8 36 5.5 6 18 12 35 5 31 M4 x 0.7 5 6 3 M8 x 1.25
Adjustment bolt (A) Adjustment bolt (B) For 90 rotation Single vane (S): 80 to 100 adjustable Double vane (D): 85 to 95 adjustable A B 180 Adjustment range of adjustment bolt (A) Adjustment range of adjustment bolt (B) 10 10 22.5 Size Allowable radial load (N) Allowable thrust load (N) Allowable moment (Nm) 1 10 15 20 0.3 A B Positioning pin hole 3 15 30 40 0.7 7 30 60 50 0.9 Adjustment bolt
16.5 19.5 B 7.5 9.5 10.5 10.5 14.0 17.0 A 33.0 32.0 34.0 27.5 31.5 32.0 B 12.5 14.5 15.5 15.5 19.0 22.0 A 26.5 25.5 27.5 21.0 25.0 25.5 B 6.0 8.0 9.0 9.0 12.5 15.5 A 27.5 26.5 28.5 22.0 26.0 26.5 B 7.0 9.0 10.0 10.0 13.5 16.5 B 4.5 6.5 7.5 7.5 11.0 14.0 A 27 20.5 24.5 25 B 8.5 8.5 12 15 20 25 32 40 50 63 Note) When setting an auto switch, confirm the operation and adjust its mounting
If either A or B is turned ON, cylinder is actuated. 1. If A is turned ON, the output turns ON. 2. Even though A is turned OFF, the output remains in ON state. 3. If B is turned ON in 2. state, the output is turned OFF.
B 89 A A B Section BB Coupling P.C.D.
1 Smooth Cylinder CQSY/CQ2Y/CM2Y/CG1Y/CA2Y 12 to 25 32 to 100 20 to 40 20 to 100 40 to 100 RE A B Minimum 0.01 to 0.03 MPa operating pressure Minimum Minimum 0.01 to 0.03 MPa operating pressure REC CX 0.04 Minimum operating pressure MPa CY 12 16 0.03 MQQ M 20 25 32 40 0.02 RHC 50 63 80 100 0.01 MK(2) 0 0 10 20 30 40 60 50 70 80 90 100 RS Q G Bore size mm RS H A (Measurement based on JIS B8377
(800) 258-9200-www.stevenengineering.com 20 25 32 40 0.02 RHC 50 63 80 100 0.01 MK(2) 0 0 10 20 30 40 60 50 70 80 90 100 RS Q G Bore size mm RS H A (Measurement based on JIS B8377) RZQ MI W S CEP1 Stable operation possible even at a low speed of 5 mm/s (Measurement based on JIS B 8377) Sliding resistance Bi-directional low-friction operation possible.
B W 12 CUJ A B W CU 16/20/25 CQS CQM W A B CQ2 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com RQ Hs 32/40/50 MU D(mm) -X D-A9 D-M9 D-F9 W Auto switch model D-F9BAL Mounting height Hs exists only for the D-F9BAL type. 20Symbol A B W A B W A B W HS 16.5 18.5 22 24
Bore size (mm) D-A73/A80 D-F7NT Electrical entry (Fetching direction) Type Model Features D-F7NT Solid state auto switch Grommet (In-line) With timer A B A B A B With pre-wired connector is available for D-F7NT type, too.
Refer to page 13-2-10 for details. (1) Valve unit (4) Adsorption confirmation switch unit K1 A V ZX1 5 Z B D M L Unit for replacement 15 C 0X B ZSP1 D Piping specifications Applicable nozzle diameter Manifold All ports are equipped with plugs.
8.5 D-H7, D-H7W, D-H7F 8.5 A Hs B Hs B 16 14 14 26 29 (36) D-C73C 8.5 A D-H7C 8.5 A Hs B B Hs 14 36.7 38.2 D-G5NT D-B5, B6 B A Hs Hs B A 24.5 24.5 13 33 13 33 Hs D-A3 D-G3, D-K3 B A 49 B Hs A 49 34 56 18 36 18 36 B D-A4 Hs A 34.5 56 18 36 Minimum Strokes for Auto Switch Mounting (mm) 1in = 25.4mm Minimum strokes are as follows based on the space required for mounting auto switches.