H (Conduit terminal: T) VXA I (DIN terminal: D) VN Main port Rc A H I J K L M R B F G N S C P T D Q U E Model LVC VNA2-10A VNA2-15A VNA3-20A VNA4-25A 3 8 1 2 3 4 63 52 2.3 42 26 25 28 4.5 34 14 72.5 80.5 74.5 79.5 82.5 124 125.5 142.5 24.3 55 LVA 60.5 73 1 80 90 84 100 92 108 62 72 2.3 2.3 50 60 31 36 30 35 35 40 5.5 6.5 43 49 17.5 20 83.5 89.5 88.5 94.5 91.5 97.5 135.5 151.5 137 153 154
HS 8.5 SMC SMC SMC SMC 16 16 A 29 Auto switch B A 26 Auto switch B (36) D-B5/B6/B59W type 20 to 40 D-G5NTL type 20 to 40 50 to 100 50 to 100 Approx. HS Approx. HS 12 12 SMC SMC 24.5 24.5 A 33 B A 33 Auto switch B D-C73C/C80C type 20 to 40 D-H7C type 20 to 40 50 to 63 50 to 63 Approx. HS Approx.
NBR JIS B2401G35 1 pc. u 4.6-30 Series AMF Dimensions: AMF150 to AMF350 M Dimensions with mounting bracket Model Port size (Nominal size B) A B C D E F G H 146 167 167 198 198 I 56 66 66 80 80 J 15 20 17 22 19 K 5 8 8 8 8 L 9 12 12 14 14 N 35 40 40 50 50 O 54 66 66 80 80 P 70 84 84 100 100 Q 26 28 28 34 34 R 4.5 5 5 5 5 S 1.6 2.0 2.0 2.3 2.3 1/8, 1/4,3/8 1/4, 3/8 5.5 6 6 7 7 139 152 158 184
Combination Spacer Select one of the spacers below when connecting to an F.R.L. combination unit (AC2000 to AC6000). (Spacers must be ordered separately.)
D-M9B D-M9N, D-M9P D-A93 Load voltage Load current range Indicator light Application 24 VDC (10 to 28 VDC) 28 VDC or less 24 VDC, 100 VAC 2.5 to 40 mA 40 mA or less 5 to 40 mA, 5 to 20 mA 24 VDC relay, PLC IC circuit, Relay, PLC Relay, PLC Solid state auto switch PLC: Programmable Logic Controller Refer to page 920 for the applicable auto switch list. 905 Rotary Actuator 11-CRA1-Z Rotation
140.5 LVR50-V19 22 80 120 169 C F E Breathing port M5 x 0.8 J Tube extensions 4 x 7 Mounting hole 1/8 (Rc, NPT) Pilot port A H D B G Breathing port M5 x 0.8 Model A B C D E LVR20-T07(06) 40 40 49.3 68 20.1 LVR40-T11(10) 82.5 82.5 89 115 33 IN C F Model F G H J K LVR20-T07(06) 8 27 56 33.5 126.2 LVR40-T11(10) 14 64.5 100 40 183.3 E K J J Breathing port M5 x 0.8 5 Applicable Fluids Regulator
0 n r Ro 18 tio ta or tio ta t f n r Ro fla an le ge ng of si +10 0 0 Ro 19 tat or io t f n r fla an gle ge sin of With external stopper For 90 For 180 Single flat Single flat 5 A A e ng ng ng le le ra ad ad t ju ju en st st m m m st en en ju t r t r ad an an gle ge ge An 5 5 B port A port B port A port 90 A 5 ng ge le an ad t r ju en st m 180 Note) The drawings show the rotation range
H G I J K L A B C D E F M R Size Tolerance +0.058 0 -0.1 -0.2 -0.1 -0.2 -0.1 -0.3 -0.1 -0.3 AD-FI-20 AD-FI-25 AD-FI-32 AD-FI-40 +0.027 0 +0.027 0 +0.027 0 +0.027 0 9 9 16 16 36 38 55 55 16 18 22 22 9 9 12 12 20 25 32 40 10 10 15.5 15.5 20 20 24 24 14 14 20 20 M8 x 1.25 M10 x 1.25 M14 x 1.5 M16 x 1.5 20 25 32 40 46 46 56 64 28 30 40 43 60 60 80 88 22 22 30 30 16 16 16 24 10 10 12 12 30 30
20 10 0 100 Suction flow [L/min(ANR)] Air consumption [L/min(ANR)] Vacuum pressure Vacuum pressure [kPa] Vacuum pressure [kPa] 80 60 Suction flow 40 20 Air consumption 0 0 10 20 30 40 Supply pressure [MPa] Suction flow [L/min(ANR)] ZHP-10 ZHP-10 (Supply pressure: 0.35 MPa) 100 90 80 70 60 50 40 30 20 10 0 0 0.1 0.2 0.3 0.4 0.5 0.6 100 90 80 70 60 50 40 30 20 10 0 100 Suction flow [L/min(
Panel mount M N Q R S T U V W Y Z AR10-A 25 28 30 4.5 6.5 40 2 18 18.5 AR20(K)-B 30 34 43.9 5.4 15.4 55 2.3 24.7 28.5 14 6 AR25(K)-B 30 34 43.9 5.4 15.4 55 2.3 25.7 32.5 16 6 AR30(K)-B 41 40 45.8 6.5 8 53 2.3 31.1 38.5 19 7 AR40(K)-B 50 54 54 8.5 10.5 70 2.3 35.5 42.5 21 7 AR40(K)-06-B 50 54 55.5 8.5 10.5 70 2.3 37 42.5 21 7 AR50(K)-B 70 66 65.8 11 13 90 3.2 AR60(K)-B 70 66 65.8 11 13 90
+ Stroke Relief port With air cushion Cushion valve (Width across flats WH) WA GA RA Relief port M5 x 0.8 WB 20 10 S + Stroke ZZ + Stroke (mm) AL Bore size Stroke range 1 2 A GB I J MM P S ZZ K NA C H RA B1 KA D H1 E F GA Standard Long 20 25 32 40 50 63 80 100 35 40 40 50 58 58 71 71 5 5.5 5.5 6 7 7 10 10 24 29 35.5 44 55 69 86 106 7 7 7 9 10 10 10 10 0 0 0 10 10 10 10 10 15.5 19.5 19.5
Never use in an atmosphere of explosive gases. The construction of auto switches is not intended to prevent explosion. Never use in an atmosphere with an explosive gas since this may cause a serious explosion. 2. Do not use in an area where a magnetic field is generated. Auto switches will malfunction or magnets inside actuators will become demagnetized. 3.
Note 2) The grommet type is equipped with a surge voltage suppressor (direct coupling type lead wire), but not an indicator light.
Furthermore, it cannot be used as an emergency cutoff valve.
l (mm) l 300 200 300 MGTL80 P = 0.5MPa m 200 MGTM80 100 P = 0.5MPa Load weight m(kg) Load weight m(kg) 40 50 100 Larger than 75st 50st 25st Larger than 50st 30 20 50 40 25, 50st 10 30 5 4 3 2 20 10 20 30 40 50 100 200 300 1 1 2 3 4 5 10 20 304050 100 200300400 Eccentric distance l (mm) 10 400 Eccentric distance l (mm) MGTL100 300 200 300 MGTM100 200 P = 0.5MPa 100 P = 0.5MPa Larger than
end (E) 32 40 Head side pivot (C) 12 12 20 40 Double rod (W) Block mount (R) Note) Minimum stroke for mounting auto switches: 0.6 inch for 2 switches, 0.4 inch for one switch.
Ball screw allowable rotation X axis specifications in-line mount (side mount) 200 20 40 W mm Motor Ball screw lead Guide Maximum work load Maximum speed Repeatability 400 750 20 40 4000 Allowable rotation rpm 20 40 3000 High rigidity direct acting guide 2000 kg mm/s mm 30 1000 15 2000 50 1000 25 2000 100(75) 1000 50(37.5) 2000 1000 0.05 (897) 1) When axes are combined, select each axis considering
Black (DC) Without an electric signal for the solenoid valve the manual override is used for switching the main valve. Locking type (Tool required) is available as an option. Red (DC) Blue 100 VAC 110 VAC 200 VAC 220 VAC Red Blue 100 VAC 110 VAC Red 200 VAC 220 VAC Push type (Tool required) Push down on the manual override button with a small screwdriver until it stops.
Never remove valve at an angle.