234 6 255 272 7 293 310 Electrical entry position: Manifold block 2-G1, 1 1/4 Type SU Formula/Stations L1 = 38n + 27 L2 = 38n + 44 Formula for manifold weight M = 0.325n + 0.39 (kg) 2 103 120 3 141 158 4 179 196 5 217 234 6 255 272 7 293 310 ( ) Electrical entry position: Valve body ( ): DC 3-9-6

L1 FB1 = WS (1+ ) FB allowable L1 L2 FB1 allowable 32 62.5 34.5 + st 80 N 40 74.0 39.0 + st 125 N 50 76.0 44.5 + st 195 N 63 91.0 44.5 + st 310 N 80 93.0 53.0 + st 500 N 100 104.0 57.5 + st 785 N e.g. 63mm bore, 100mm stroke, Ws = 20N Ws = (2kgs) 20N 144.5 91 FB1 = 20 (1+ ) = 51.76N Replacement parts: Seal kits 32 includes order No. from to , 40 100 includes from to FB1 = 51.76N 310N

Load weight (kg) m1 m2 m3 Moment (Nm) M1=F1 x L1 F1 F2 M3=F3 x L3 F3 M2=F2 x L2 L1 L2 L3 Maximum load weight 1. Maximum allowable load (1), static moment (2), and dynamic moment (at the time of acceleration/deceleration) (3) must be examined for the selection calculations.

Load (kg) m1 m2 m3 Moment (Nm) M3 = F3 x L3 F3 M1 = F1 x L1 F1 M2 = F2 x L2 F2 L1 L2 L3 1. Maximum allowable load (1), static moment (2), and dynamic moment (3) (at the time of impact with stopper) must be examined for the selection calculations. To evaluate, use a (average speed) for (1) and (2), and (impact speed = 1.4a) for (3).

L2 Weight (g) L1 D A Part No. KBP1 KBP2 KBP3 KBP4 11.5 16.8 21.0 28.6 30.4 29.5 23.0 25.5 27.0 8 10 14 19 19.0 12.5 14.0 15.0 5.6 6.8 13.4 24.0 5.0 Cap: KBC H (Hex.) 14 17 19 24 L2 Weight (g) Part No.

(mm) 10 9 8 7 6 5 4 3 Manifold stations n L1 L2 2 180 165 150 135 120 105 90 75 60 235.5 223 198 185.5 173 160.5 148 123 110.5 8

Thread Size RNPT Thread Size R(NPT) A E H L1 L2 M L1 LQ3L1A-M LQ3L2A-M LQ3L2B-M LQ3L3A-M LQ3L3B-M LQ3L3C-M LQ3L4A-M LQ3L4B-M LQ3L4C-M LQ3L5A-M LQ3L5B-M LQ3L5C-M LQ3L6A-M LQ3L6B-M LQ3L6C-M 12.5 10 11 14 26 16.5 1/8" 1/8" 1/4" 1/8" 1/4" 3/8" 1/4" 3/8" 1/2" 3/8" 1/2" 3/4" 1/2" 3/4" 1" 1/8" 16.5 17 16 20 33.5 22.5 1/4" 21.5 22.5 21 25 46 28 3/8" L2 (A) M 25 24.5 24 29 54.5 33 1/2" 1/4 (E) H 30.5

Please refer to the catalogue to confirm the sizes of the fittings to be used. n: Number of stations (mm) Dimensions 5 6 1 26 52 2 36 52 3 46 62 4 56 72 5 66 82 6 76 92 7 86 102 8 96 112 n L1 L2 EXH EXH P PE P PE V V V V Circuit ZQ13M-K1-D ZQ13M-K2-DK ZQ13M-J1-F ZQ13M-Q1-FK 9 Series ZQ Manifold Exploded View 6 3 6 4 6 b b view 4 6 2 a 5 a 5 5 Component Parts No.

Power supply voltage is 200VAC single phase Trouble OFF ON RA MC Emergency stop MC SK (Note 6) Driver Servo motor Servo amplifier (Note 7) Controller CNP1 MC NFB 1-phase 200 to 230VAC L1 CNP3 (Note 5) U L2 U Motor V L3 V [1] M W N W P1 (Note 1) P2 PE CNP2 P [2] (Note 2) C [3] D Encoder CN2 (Note 3) Encoder cable L11 L21 [1] Provide specified power supply to input terminals L1 and L2. [2]

DC (Note 12) CN3 (Note 5) Forced stop 2 DOCOM DICOM 24 V DC (Note 12) Malfunction (Note 4) (Note 5) ALM CN8 RA1 (Note 9) Short-circuit connector (Packed with the servo amplifier) [1] Power supply input terminals, L1, L3: Provide specified power supply to input terminals L1 and L2. [2] Connect the motor power supply input terminal (U, V, W) to the driver power terminal (U, V, W).

62.5 125 162.5 200 237.5 275 L3 73 135.5 173 210.5 248 285.5 C(4 ) C(6 ) F(G ) H 13 13.6 19 -21No.PS-OMR0001CN-J 2 ISA3--B-L () ISA3--B-L 1ISO16030 2ISO1179-1 1 2 3 4 5 6 L1 55.6 93.6 131.6 169.6 207.6 245.6 L2 136.4 174.4 212.4 250.4 288.4 326.4 C(4 ) C(6 ) F(G ) H 13 13.6 19 -22No.PS-OMR0001CN-J 2 ISA3--B-R ISA3--B-R ISA3--B-LN ISA3--B-RN 1ISO16030 2ISO1179-1 1 2 3 4 5 6 L1 55.6

62.5 125 162.5 200 237.5 275 L3 73 135.5 173 210.5 248 285.5 C(4 ) C(6 ) F(G ) H 13 13.6 19 -22No.PS-OMT0001CN-E 2 ISA3--B-L () ISA3--B-L 1ISO16030 2ISO1179-1 1 2 3 4 5 6 L1 55.6 93.6 131.6 169.6 207.6 245.6 L2 136.4 174.4 212.4 250.4 288.4 326.4 C(4 ) C(6 ) F(G ) H 13 13.6 19 -23No.PS-OMT0001CN-E 2 ISA3--B-R ISA3--B-R ISA3--B-RN ISA3--B-LN 1ISO16030 2ISO1179-1 1 2 3 4 5 6 L1 55.6

M12 32 /NPN() 3 M12 16 /PNP() 4 M12 16 /NPN() MJ CC-Link -8No.EX-OMP0004CN-I 1 (BUS OUT) CC-Link () 1 (M12 5 A code) 2 (BUS IN) CC-Link (IN ) 1 (M12 4 A code) 3 SI 1 (M12 5 B code) 4 (M3 ) 5 6 LED SI 2 7 SI (M330) SI 2 (BUS OUT)(1 ) 128 2LED 16 -9No.EX-OMP0004CN-I SI n L 1 2 3 4 5 6 7 8 L1 120.7 136.7 152.7 168.7 184.7 200.7 216.7 L2

Add to Cart SMC GDM2A-L1 din connector, VX2 2-WAY MEDIA VALVE*** $15.09 Add to Quote Add To Cart Add to Cart SMC GDM2A-L2

Add to Cart SMC GDM2A-L1 din connector, VX2 2-WAY MEDIA VALVE*** $15.09 Add to Quote Add To Cart Add to Cart SMC GDM2A-L2

Add to Cart SMC GDM2A-L1 din connector, VX2 2-WAY MEDIA VALVE*** $15.09 Add to Quote Add To Cart Add to Cart SMC GDM2A-L2

. *1 Made to order (Produced upon receipt of order) r Output specification *2 Made to order (Produced upon receipt of order) y Unit specification t Option 1 Symbol OUT1 OUT2 L IO-Link/ NPN/PNP M SI unit only*4 Nil W Lead wire with connector (2 m) Lead wire with connector (2 m) + Connector cover (Silicone rubber) Nil Unit selection function*5 L2 IO-Link/ NPN/PNP NPN/PNP/External input *

-X 20m2 m3 Data Moment (Nm) M1 = F1 x L1 F1 F2 M3 = F3 x L3 F3 M2 = F2 x L2 L1 L2 L3 Maximum Load Weight Select the load from within the range of limits shown in the graphs. Note that the maximum allowable moment value may sometimes be exceeded even within the operating limits shown in the graphs. Therefore, also check the allowable moment for the selected conditions.