the 1 mm interval with no stroke adjustment by spacer.
If you change by these by mistake, it may cause the amplifier to not work properly. -24- 5.3.4 Recommended Parameter Values by Actuator Model Please change the parameter values according to the customer application. Refer to LECSC Operation Manual,chapter 6 for details.
If you change by these by mistake, it may cause the amplifier to not work properly. -24- 5.3.4 Recommended Parameter Values by Actuator Model Please change the parameter values according to the customer application. Refer to LECSC2-T Operation Manual,chapter 6 for details.
Note 3) Indicate Mixed sizes and with port plug by means of the manifold specification sheet.
Note 3) Indicate Mixed sizes and with port plug by means of the manifold specification sheet.
The average velocity of the cylinder is what the stroke is divided by the total stroke time.
The required lifting force is then found by dividing the theoretical lifting force by the safety factor t.
Select it by referring to Allowable Stroke Speed below.
The failure was a secondary failure of the product caused by the failure of equipment connected to the product. 4. The failure was caused by a natural disaster such as an earthquake, typhoon, or flood, or by an accident or fire. 5. The failure was caused by operation different from that shown in the Operation Manual or outside of the specifications. 6.
When the counter is reset by pressing the cylinder rod to the reference plane, that point becomes the home position.
Protection from e.g. static electricity caused by the process or connected equipment must be considered by the user (EN 60079-146).
Highly reliable construction Safety limit switch can be selected. q The main valve position is detected by transferring the main valve movement directly to the reed safety limit switch with the rod. Safety limit switch Main valve Rod Made by Rockwell Automation Made by OMRON Conduit (VP series only) and M12 connector (4 pin) types are available.
A shifting of the plugs is not required by the customer.
Note 2) The accessories should be mounted by user.
Resolution is determined by specifying the upper and lower scale limit.
Repair for the trouble or damage should be paid by the customer. Trouble and damages caused by natural disaster fire, flood, lightning strike and others Troubles and damages caused by reconstruction without our approval. Troubles and damages caused by works or operations with ignoring the instructions of the manual. Trouble and damages caused by wrong handling.
Note) Applicable stroke available by the 1 mm interval.
For models IDU8E to 15E1, the humid and hot air introduced to the air dryer will be cooled down by the aftercooler before being cooled down by the heat exchanger.
Furthermore, if the cable length exceeds 5 m, then it will decrease by up to 10% for each 5 m. (At 15 m: Reduced by up to 20%) *5 The allowable speed for pushing operation.
Set by using the UP and DOWN buttons.