Order separately with part number, AS-T-1. 100 200 205 300 400 M5 standard 1/8 standard 1/4 standard 3/8 standard Made to Order (Refer to page 608 for details.) Applicable tubing O.D.
With One-touch fitting Port size U01 Uni 1/8 U02 Uni 1/4 U03 Uni 3/8 U04 Uni 1/2 Needle Valve/Flow Rate Characteristics AS2201F-U02, AS2211F-U02 AS2301F-U02, AS2311F-U02 AS2201F-U01, AS2211F-U01 AS2301F-U01, AS2311F-U01 600 300 Inlet pressure: 0.5 MPa Inlet pressure: 0.5 MPa 06, 07, 08, 09, 10 500 08, 09, 10, 11 Flow rate L/min (ANR) Flow rate L/min (ANR) 03, 04 06, 07 200 400 01, 23 300
[mm] 300 100 200 50 100 50mm/s 20 25 32 40 0 1.0 0 2.0 10 Time [s] Cylinder size [mm] 4.10-2 Series RHC low/medium speed opration with heavy loads 20 , 25 , 32 , 40 Cushion Ring MK/MK2 RSQ/RSG The long cushion ring can absorb larger energy (in terms of speed and weight).
Example: Power supply is 24 VDC Internal voltage drop in auto switch is 4 V. 12 JMGP Series Specific Product Precautions 1 Be sure to read this before handling the products. Refer to the back cover for Safety Instructions.
A One-touch fittings KP series B Dimensions (mm) Model A B C SFE4G 6 68.5 16.5 SFE5H 8 79 20.5 SFE7J 10 89 24 Bracket SFE-BR3 14 5 3.4 (15.5) 12.5 5.4 5.4 14 24 (20) SFE-BR4/5/7 B C (J) H D (F) G A E E Dimensions (mm) Model A B C D E F G H J SFE-BR4 30 16 7 4.5 7.5 (24.5) 17 15.5 (19.5) SFE-BR5 30 10 8.2 4.5 8.1 (29) 20 18 (23) SFE-BR7 34 14 7.35 4.5 9.8 (35) 24 20 (27.3) ( ): Reference dimensions
Supply 24 V DC 10% for interfaces from outside. Set the total current capacity to 300 mA. 300 mA is the value applicable when all I/O signals are used. The current capacity can be decreased by reducing the number of I/O points. The illustration of the 24 V DC power supply is divided between input signal and output signal for convenience. However, they can be configured by one. 11.
Recommended Parameter Values [LEF] LEFS25 LEFS32 LEFS40 Lead symbol H A B H A B H A B Series Lead 20 12 6 24 16 8 30 20 10 Parameter *1,*2 Para. Initial value Recommended value No.
single Operating pressure range VFA1000 series 101.2 kPa to 1.0 2 position double/3 position Note 2) (MPa) SYA (0.4 x P + 0.1) to 1.0, P: Operating pressure 2 position single Pilot pressure range 0.1 to 1.0 2 position double SYJA (MPa) 0.15 to 1.0 3 position VFA3000 series Ambient and fluid temperature (C) 10 to 50 (No freezing) VZA Not required Lubrication Free Mounting orientation VFA VFA 300
Contents Bore size (mm) Lube, non-lube, air-hydro Standard (lube) CS1-125A-PS 125 140 160 180 200 250 300 CS1-125A-PS CS1-140A-PS CS1-160A-PS CS1-180A-PS CS1-200A-PS CS1-250A-PS CS1-300A-PS @3 24 @5 @6 @7 @8 29 #0 31 Wiper ring CS1-140A-PS Cushion seal CS1-160A-PS Component part numbers: @3, @5, @6, @7, @8, #0.
Changes from the standard type are: SL5201mmA SL5201 SL5202 SL5210 SL5206 Option Other Parameters HF Cv Supply pressure effect 0.15 0.50 psig (0.0035 MPa) rise in delivery pressure per 20 psig (0.14 MPa) source pressure drop 24 Single Stage Compact Regulator for Ultra High Purity Series SL5200 AZ AK KT BP Diaphragm Valves Check Valves Vacuum Generators Flow Switches Technical Data/ Glossary
Dimensions Dimensions 4-R2.5 12 25 41.5 17 34 24 R16.5 Panel nut Gasket 26 11 1.5 24 44 Max. panel thickness 4.5mm 5.4 1.6 54 Install the gasket underneath the panel and bracket (bonnet side).
/My max. 0.3 Stroke (mm) Stroke (mm) 10 15 20 25 30 5 25 30 10 15 20 5 0.2 MXPJ6 3.5 2.6 2.3 1.4 MXP10 4.2 8.5 1.7 6.3 50 100 200 300 500 700 MXP12 9.8 17 13 4.5 Average speed Va mm/s Collision speed V mm/s MXP16 26 41 28 12 1 Nm = 0.7375 ftlbf Note) Average speed is used at static moment calculation. Collision speed is used at kinetic moment calulation.
Note 2) When compressor discharge concentration is 30mg/Nm Specifications Models Model AMG150 AMG250 Drain Catch Series AMG Compressed air 1.0MPa Fluid Maximum operating pressure Rated flow rate Note) l/min (ANR) 300 750 Note) 0.05MPa Min. operating pressure Proof pressure The AMG series is installed in air pressure lines to remove water droplets from compressed air.
N.C. 3 2 1 300 13 16 5.5 2 x 2.8 UL1007 AWG22 4.5 16.5 For LVM12R 57 2 x 2.7 Mounting hole Push type Manual override N.O. N.C. 3 2 1 N.O.
100 200 300 400 Flow rate L/min Flow rate L/min (ANR) Flow rate L/min (ANR) SRH3100-02 SRH3110-02 SRH3100-02 0.5 0.20 0.20 0.4 Outlet pressure MPa 0.15 0.15 0.3 0.10 0.10 0.2 0.05 0.05 0.1 0 100 200 300 400 0 2 4 6 400 100 200 300 0 Flow rate L/min (ANR) Flow rate L/min (ANR) Flow rate L/min SRH4000-03 SRH4010-03 SRH4000-03 0.5 0.20 0.20 0.4 Outlet pressure MPa Outlet pressure MPa Outlet
Caution One-touch fitting Dimensions VDW30-G--P7 / P7 Quick Fastener VDW40-G--P10 / P10 Quick Fastener 30 36 Approx. 300 21 23 32 18 20 27 Approx. 300 56 48 10 9 P7 1 (IN) port P7 2 (OUT) port 50 21 P10 1 (IN) port P10 2 (OUT) port 56 VDW40-5G--P10--N VDW30-5G--P7--N 16 12 2 x M3 x 0.5 thread depth 4 2 x M3 x 0.5 thread depth 5 Male Quick Fastener Dimensions Quick Fastener Clip Dimensions
0.25 0.25 0.20 0.20 AMR 0.15 0.15 ITV 0.10 0.10 IC 0.05 0.05 0 0 50 100 150 200 250 300 350 400 450 500 0 0 50 100 150 200 250 300 350 400 450 500 VBA Flow rate (/min (ANR)) Flow rate (/min (ANR)) VE VY1 G Pressure Characteristics PPA Inlet pressure: 2.0 MPa Outlet pressure: 0.8 MPa Flow rate: 60 /min (ANR) Inlet pressure: 2.0 MPa Outlet pressure: 0.3 MPa Flow rate: 60 /min (ANR) AL ARX20
S = 38mm VCA21 200 300 400 500 600 700 VCA21 VCA31 VCA31 VCA41 VCA41 VCA41 Other 200 400 400 600 800 1000 1200 1. Material HNBR: Nitrile hydride rubber 500 700 500 1000 1500 800 1000 1200 1000 500 Flow rate Q l/min (ANR) Viewing the graph The sonic range pressure to generate a flow rate of 500l/min (ANR) is P = 0.64MPa for a 3 orifice, and P = 0.35MPa for a 4 orifice.
N.C. 3 2 1 300 13 16 5.5 2 x 2.8 UL1007 AWG22 4.5 16.5 For LVM12R 57 2 x 2.7 Mounting hole Push type Manual override N.O. N.C. 3 2 1 N.O.
(mm) ASG32F-01 4 ASG42F-02 6, 8 ASG52F-03 6 ASG62F-04 Sealant: Special FKM Seat ring: Stainless steel 303 8 12 4, 6 8, 10 10, 12 460 920 790 1580 100 180 230 390 Flow rate (l/min (ANR)) Controlled (free) flow 7 14 12 24 1.5 2.7 3.5 6 Effective area (mm2) Applicable tubing materials Note) Flow rate is measured at 0.5 MPa and 20C.