type (without silencer) 10/Rc 1/4 8/Rc 1/8 Threaded Threaded 6/Rc 1/8 6/Rc 1/8 6/Rc 1/8 6/Rc 1/8 10/Rc 1/4 6/Rc 1/8 8/Rc 1/8 10/Rc 1/4 12/Rc 3/8 12/Rc 3/8 8/Rc 1/8 10/Rc 1/4 12/Rc 3/8 12/Rc 3/8 16/Rc 1/2 16/Rc 1/2 Refer to page 3.4-1 of No. 3 for details.
(For B: Basic) CM2 Bore size GA P Bore size GA P 20 14 M5 x 0.8 50 (14) (Rc 1/4) 25 13 M5 x 0.8 63 (14) (Rc 1/4) 32 (12) (Rc 1/8) 80 (20) (Rc 3/8) 40 (13) (Rc 1/8) 100 (20) (Rc 1/2) 2 x P GA CM3 CG1 CG1 * When female thread is used, use a washer, etc. to prevent the contact part at the rod end from being deformed depending on the material of the workpiece. ( ): Same as the standard model.
(Effective energizing time is over 62 ms at 24 VDC.)
22 22.5 19.5 24 22 10 20 24 21 24 52.5 50.5 48.5 45.5 52.5 50.5 29 25 29 7.5 LQ3T41-R5 12 10 24 22 22.5 19.5 24 21 52.5 50.5 48.5 45.5 29 25 LQ3T51-R1 19 12 19 7 26.5 24 24 22 26.5 24 14 28 32 24 32 64 61.5 58.5 56.5 64 61.5 37 29 37 9.5 LQ3T51-R5 19 12 26.5 24 24 22 32 24 64 61.5 58.5 56.5 37 29 LQ3T61-R1 25 19 25 8 30 26 26.5 24 30 26 18 36 41 32 41 78 74 70 67.5 78 74 49 37 49 16 LQ3T61
Nil Rc N PNP output ( COM.)
current 100 A or less at 24 VDC 0.8 mA or less at 24 VDC MHC Indicator light Red LED lights when ON.
1/8 60 30 206 12 42 16 16 6 14.5 15 12.5 MY1B25 55 6 10 16 28 38.5 46 220 Rc 1/16 Rc 1/8 80 35 264 17 51 16 23 4 16 16 16 MY1B32 70 10 10 19 32 48 55 280 Rc 1/16 Rc 1/4 100 40 322 18.5 59 24 27 10.5 20 22 19.5 MY1B40 23 36 340 14 67 Rc 1/8 60.5 85 12 P indicates cylinder supply ports. 2-d Y S R WX D Bottom ported (ZZ) (Applicable O-ring) Hole Size for Centralized Piping on the Bottom WX
Electrical entry 24, 12 VDC/ 100, 110, 200, 220 VAC 24, 12, 6, 5, 3 VDC 24, 12, 6, 5, 3 VDC/ 100, 110, 200, 220 VAC Gasket assembly part no.
Stations 24 [23] 58 28 105.5 176.5 209 9 9 20 70 [71.5] 2n-Rc 1/2 VZS D side Plug assembly: VVFS2000-30A(Option: Refer to page 3-5-8.)
Proper tightening torque (Nm) Tightening Torque for Piping Connection thread 7 to 9 12 to 14 22 to 24 28 to 30 Rc Rc Rc Rc 1 8 1 4 3 8 1 2 5. Piping to products When piping to a product, refer to the operation manual to avoid mistakes regarding the supply port, etc. Back page 5 5 Port Solenoid Valves Precautions 4 Be sure to read this before handling.
Model HTB 1 8 Rc CY1S20 CY1S25 CY1L25 CY1S32 CY1L32 CY1S40 CY1L40 20 20 7.5 20 20 7.5 1 8 Rc 20 23 8.2 24 24 7.5 1 8 Rc 26.5 26.5 8.2 25 25 8 1 4 Rc 30.5 30.5 11 Dimensions except mentioned above are the same as standard type of Series CY1B. Refer to page 8-15-24.
Note 2) AS1000, AS2000 are not applicable. 8 3 2 1 Bore size 2 1 Bore size Applicable series M3 M5 01 02 03 04 M3 x 0.5 M5 x 0.8 Rc 1/8 Rc 1/4 Rc 3/8 Rc 1/2 AS1000 AS1000 AS2000 AS2000/3000/4000/5000 AS3000/4000/5000 AS4000/5000 Thread type Nil Metric thread (M3, M5) Rc NPT G N F Caution Be sure to read before handling.
Proper tightening torque Nm Connection thread 7 to 9 Rc 1/8 12 to 14 Rc 1/4 22 to 24 Rc 3/8 28 to 30 Rc 1/2 5. Connection of piping to products When connecting piping to a product, refer to its instruction manual to avoid mistakes regarding the supply port, etc. 1= nm 109 Series SV 5 Port Solenoid Valve Precautions 3 Be sure to read before handling.
V 0 V 0 V 24 V G D G D SI unit SI unit Master unit D 0 V24 V G D 0 V24 V G D 0V 24V G D 0V 24V L2 L1 G LINE1 LINE2 SHIELD L1 L2 Power supply 24 V 0 V 0 V 24 V SHIELD SHIELD Transmission line L1 L2 FG 24 V 0 V L1 L2 FG 24 V 0 V Black White Brown Blue Terminal resistor Main transmission line Transmission line Crimped connector SL-J1A Power supply 24 V 0 V 0 V 24 V Type 3 ground Type 3 ground
Dimensions: With Adapter ZPT H-A14 (Male thread) 40 50 ZPT H-A16 (Male thread) 63 80 ZPT H-A16 (Male thread) 100 125 1/8 (Rc, NPT, NPTF) 1/8 (Rc, NPT, NPTF) Width across flat 22 (Hexagon) Width across flat 19 (Hexagon) 1/8 (Rc, NPT, NPTF) Width across flat 22 (Hexagon) 4 x M5 x 10 Width across flat 19 (Hexagon) 70 45 4 x M4 x 8 28 E Width across flat 24 (Hexagon) Width across flat 24 (Hexagon
(mm) Thread RC(PT) Part No.
1/16 25 32 40 Rc 1/8 19 30 26 Rc 1/8 18 16 24 4 21 16 19 13 48 Rc 1/16 23 36.5 32 Rc 1/4 16.5 26 25.5 10.5 22.5 24.5 23 20 54 Rc 1/8 "P" indicates a cylinder supply port.
16.5 31 1 8 Rc 1 8 Rc 1 8 Rc 1 8 8 9 10.5 26 32 40 40 50 62 3 4 5 8 10 12 9 10 11 8 10 12 16 20 24 20 22 29 33 43.5 51.5 33.5 34 34.5 6.6 5 to 50 19 21.5 23 8 5 to 50 11.5 5 to 50 L H J P Q QA R S SA T W Y Z Model ZC(D)UKD16 ZC(D)UKD20 ZC(D)UKD25 ZC(D)UKD32 ( ): In the case of a mounted auto switch.
ITV IC 1 2 Proper tightening torque (Nm) Tightening Torque when Piping VBA Connection threads Rc 1/4 12 to 14 VE Rc 3/8 22 to 24 Terminal 1 2 Rc 1/2 28 to 30 DIN terminal + VY1 Rc 3/4 28 to 30 Rc 1 36 to 38 G Lubrication 4. Piping to products When piping to products, avoid making an error of supply port, etc., by referring to the instruction manuals. 5.
Non plug-in type Thread type 02 2 stations Standard Nil NPT Rc N T F Symbol 24 24 stations NPTF G Option 1 5 2 VV5ZS2-51FD-091-01-MP5 VZS2150-5FZ VZS2250-5FZ Note) Maximum stations 51F 16 stations 51G15 stations 51 24 stations Passage Porting specifications 4(A), 2(B) Side 5(R1), 3(R2) 1(P) Common Common Symbol Port size 1 1 8 01 Rc (Manifold base) (2 position single) 1 5 VV5ZS2-51-071-