<br>However, the suck back valve on its own is only capable of changing the volume by moving the diaphragm up and down, so it cannot stop the fluid. <br>Therefore, a stop valve (2-way valve) is required on the inlet side of the suck back valve.<br><br>
<br>It can be found here. <br>TL/TIL and TLM/TILM series tubing with the “-2S” part number suffix are the 2 m straight type, which does not curl.<br><br>
<br>Since the diaphragm type process pump is not a metering pump, the discharge rate per cycle varies. <br>The “discharge amount A per cycle” is the value obtained by flowing a specified amount of liquid from each process pump and dividing the amount by the number of operation cycles.<br><br>
<br>For deionized water (pure water), replace all the water regularly because of the possibility of bacteria and algae generation inside the tank. <br>Take measures to prevent the generation of static electricity in the piping as well. <br>Refer to the “Specifications” section in the catalog for other applicable circulating fluids.
<br>Due to their Peltier type element, they are capable of both cooling and heating. <br>Note that HECR series thermo-cons can only be rack mounted. <br>Please refer to the catalog for details. <br>The HEC series catalog can be found here.
<br>Check that there is no leakage in the piping, including the customer’s device. If there is no leakage, supply circulating fluid according to section “3.5 Fill of circulating fluid” in the HRS series operation manual. <br>Depending on the problem, however, consider requesting maintenance from a maintenance company. <br>We can recommend service providers if needed.
<br>For details on resetting alarms, refer to section “5.18 (and 5.8) Accumulated Time Reset Function” in the HRS series operation manual, which can be found here. <br>Note that there is no alarm code “AL29” (fan motor maintenance) for water-cooled thermo-chillers. <br>Note 1) Every 30,000 hours for the HRS090 to 200 and the HRSH series
<br>Identify the model, and then refer to the catalog to determine the filtration rating. <br>Note that the nominal filtration accuracy is indicated on the side of sintered elements, and for bag filter elements, it is indicated on the tag at the top of the element.<br><br>
<br>Information on industrial filter selection can be found here.<br>The differences between the 2 are as follows. <br>Seal material: Select from NBR or FKM for the FQ1 series and NBR or fluororesin for the FGD series.<br>Housing material: Only stainless steel 304 is available for the FQ1 series.
Applicable load Type Load voltage Auto switch model Band mounting DC AC 0.5 (Nil) 1 (M) 3 (L) 5 (Z) Lead wire length (m) Wiring (Output) Electrical entry Indicator light M9B M9BW 5 V 12 V 24 V 2-wire Yes Grommet Solid state auto switch Relay, PLC A93 100 V Yes 12 V 24 V 2-wire Grommet Reed auto switch Note 2) Auto switches marked with are produced upon receipt of order.
How to Order B 32 30 D C CQ2Y Standard B F9BW S 32 30 D C CDQ2Y With auto switch Number of auto switches With auto switch (Built-in magnet) 2 pcs. 1 pc. n pcs.
Magnet: Built-in, Mounting: Foot, Bore Size: 50mm, Port Thread Type: G, Stroke: 30mm, Body Option: Rod End Male Threads, Locking Direction: Extension Locking, By-Pass Piping: None (Emergency Stop), Auto Switch: F7PW--Solid State, 2-color Indication, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: 0.5m Cord Length, M12-4 Pin Connector
Applicable load Type 2-wire 3-wire Solid state auto switch Auto switch model D-M9B(V) D-M9N(V) Load voltage 24 VDC (10 to 28 VDC) 28 VDC or less 5 to 30 mA 50 mA or less Load current range Indicator light Yes Yes 24 VDC relay, PLC PLC: Programmable Logic Controller Refer to page 946 for the applicable auto switch list.
13 30.6 24 42.5 24.5 7.5 22 15 0.02 0.02 0.05 MHZ2-20D 8 18 84.8 10 16.8 50 18.6 7.5 27.6 35 15 42 30 52.8 29 9.5 32 20 0.02 0.02 0.05 MHZ2-25D 102.7 63 33.6 52 63.6 11 25 10 12 22 36.5 36 30 40 22 21.8 10 20 0.02 0.02 0.05 U V W X Y Z AA AB AC AD AE AF AG AH AJ AK Model 1122+0.043 0 +0.043 0 +0.052 0 +0.052 0 +0.025 0 +0.025 0 +0.030 0 +0.030 0 MHZ2-10D 12.4H9 M2.5 x 0.45 12 19.5 28.2 5.5
Auto switch precautions P.30 1) Applicable auto switches P.30 2) Precautions for use P.32 -1- 3A 3/5 Safety Instructions These safety instructions are intended to prevent hazardous situations and/or equipment damage. These instructions indicate the level of potential hazard with the labels of Caution, Warning or Danger.
(mm) 50 30 63 30 80 40 1-4. (mm) (Kg) 50 1.70 / 63 2.78 80 4.96 4 - RS1H 1. mA 2. V(m/min) (Kg) 3.
<br>These valves can be used for stopping a cylinder at an intermediate position, vacuum suction, vacuum break, and selector valves and divider valves.<br>Further details on the VEX3 series can be found here.
<br>Note 1) Air of up to 9.5 L/min (ANR) [at a supply pressure of 1.0 MPa] is constantly exhausted (consumed) from the PE port for high-precision pressure regulation. <br>Note 2) Install a mist separator on the supply side in addition to the filter. <br>Note 3) When the outlet pressure is higher than the set pressure, the R port is used for exhaust until the set pressure is reached.
<br>Note) For a single unit single solenoid, exhaust is not performed from the Y port (the side without a pilot valve).<br><br>
<br>For the new type, there is a “1” added after the symbols for voltage, electrical entry, and manual override method.<br>The low-wattage type “Y” is now the standard specification, so a “Y” is no longer required in the part number.<br>Note) For the SQ2231D-5-C6, the product with an equivalent response time is the SQ2231BD-51-C6. (The type with a “B” is the high-speed response type.)