SMC Corporation of America
Elite Part Number Search
Search Results "RZQA40TN-150-60-M9BZ"

Flow Rate: 2.4 CFM / 4.2 m3/hr / 68 LPM , 2.4 CFM / 4.2 m3/hr / 68 LPM, Max Vacuum: 25.4 in HgV / 115 Torr / -861 mbar , 25.4 in HgV / 115 Torr / -861 mbar, Horsepower (60 Hz): .2, Voltage (60 Hz): 115, Voltage (50 Hz): 115, Frequency (Hz): 50 / 60, Phase: 1-phase, Item Dimensions: Length: 8.07 in / 205 mm Width: 5.98 in / 152 mm Height: 5.91 in / 150 mm

200 250 0 0 50 100 150 200 Flow rate L/min (ANR) Flow rate L/min (ANR) ARM5AA1-308 (One-touch fittings: IN/OUT 6) Condition: Inlet pressure 0.7 MPa ARM5AA1-308-1 (One-touch fittings: IN/OUT 6) Condition: Inlet pressure 0.5 MPa 0.7 0.35 0.6 0.30 0.5 0.25 0.4 0.20 0.3 0.15 0.2 0.10 0.1 0.05 0 0 50 100 150 200 250 0 0 50 100 150 200 250 Flow rate L/min (ANR) Flow rate L/min (ANR) ARM5AA1-309

Caution Be sure to read before handling.Refer to pages 14-21-3 to 4 for Safety Instructions and Common Precautions on the products mentioned in this catalog, pages 14-14-6 to 8 for Precautions on every series, and pages 14-20-62 to 64 for more detailed precautions on every series. 14-20-22 2 Micro Mist Separator Series AMD How to Order AMD150 to AMD850 AMD 250 03 J B Body size Option 1 4 150

P . 14-20-57 14-20-42 2 Odor Removal Filter Series AMF How to Order AMF150 to AMF850 AMF 250 03 R B Option R IN-OUT reversal direction Body size Bracket Accessory (Option) 150 Standard 1 8 250 Standard 1 4 350 Standard 3 8 450 Standard 1 2 550 Standard 3 4 650 850 B 1 4 B 3 8 04 B 1 2 06 B Nil Nil B Piping port (B dimension) 1 Standard 11 2 Standard 01 B 1 8 02 03 Thread type Nil Rc F G N

Table 4-1 EX245 24 V DC +20% -15% 1ms IP65 () (IEC60529) 10M -FE 500VAC IEC61131-2 500VAC1 -FE IEC61131-2 -10 to 50 -20 to 60 35%85% RH 80 kPa 108 kPa ( 2000 m ) 66 kPa 108 kPa ( 3500 m ) 10 Hz to 57 Hz 0.75 mm 57 Hz to 150 Hz 49 m/s 2 XYZ 2 XYZ 3 EN 60068-2-27/29 EMC , 2014/30/EU, IEC61326-3-1 , 2006/42/EC, EN 62061, EN ISO 13849 TUV , EN 61508, EN 62061, EN ISO 13849

Micromist separator AMD900, 1000, 901 Model Connect (Flange) 2B 6B C 2B/3B/4B 400 A 280 B 760 D 150 E 270 F 1033 G 3 H 887 J 620 AMD801 AMD901 12B 445 795 300 520 1318 3 972 AMD800/900/1000 ORIENTATION Mounting Caution q Verify the direction of the flow of the compressed air and the "e" mark that indicates the inlet of the product before connecting.

180 65 85 120 130 180 220 60 76 110 102 136 184 4.5 4.5 6 239 291 403 22 32 42 128 167 235 122 160 220 3 122 160 220 10 10 10 AMF550 AMF650 AMF850 1 2 1 2 1 2 1 AMF450SAME, #4 AMF550SAME, #5 AMF650SAME, #6 AMF850SAME, #7 4.6-32 Series AMF Precautions Dimensions: AMF801/901/800/900/1000 AMF801/901 Be sure to read before handling.

, 175 200, 250, 300, 350 12 13 107 44 20 16 47 64 148 M8 35 64 19 50 11 7 14 115 49 20 16 50 78 162 M10 38 77 19 63 16.5 16.5 13.5 6.5 16.5 Bore size (mm) J K L MM ML NN OA OB OL P PA PB PW Q R S T U VA 18 M8 x 1.25 7.5 M8 x 1.25 27 27 40 20 6.6 11 1/8 38 30 104 44 118 86 106 40 13 21.5 9 M10 x 1.5 9 32 32 46 22 8.6 14 1/4 47 40 130 60 146 110 130 50 M10 x 1.5 14 28 39 39 58 22 8.6 14 1/4

Normally Closed SERIES NVF 110 DIRECTIONAL AIR VALVE DIRECT SOLENOID OPERATED CHARACTEFISTICS Port Sizss (NPTO '10-32 P&E; 10-32 or 1/8"A Opelating Prsssure 0'100 PSI; 0-150 PSI (H) ftoof Pre6sur 225 PSIG (15Kgflcm'z) Operailng Temperature 14-140'F(101o + 6O"C) a;a lnrusn s.6 VA (50 Hz),5.0 VA(60 Hz) Holding 3.4 VA (50 Hz),2.3 VA (60 Hz) PowerConaumptlon DC 1 . 8 W c, 0.055 , 0.05 (H Type

MADE IN G IDF100150F i-2 i-6 IDX-OM-U021 i i-3 HFC IDF100150F i-3 i-7 IDX-OM-U021 i i-4 / 1 1.5 () IDF100150F i-4 / i-8 IDX-OM-U021 1 1 1-1 i.2.9 1 2 IDF100F-30 C.RV IDF100F-30-CRV1 IDF 100 F 30 C 1 2 G 3 K 100 125 150 ) 100kW 125kW P 150kW ) R V 30 AC200V(50Hz) AC200/220V(60Hz) 1 C 1 G 2 K 3 P R V 1-1 IDF100150F 1 1 IDX-OM-U021 1 1-2 1-2-1 (C) 1-2-2 G 1-2-3 K

Not required Unrestricted 150/30 Note 1) Be certain that pressure within operating pressure range be supplied to supply port, because return pressure is introduced from supply port {1(P)} for activation. Note 2) Impact resistance: No malfunction resulted from the impact test using a drop impact tester.

Valve Solenoid Max.operating frequency 20Hz 5Hz Individual EXH Pilot valve EXH Not required Lubrication Non-locking push style/Locking slotted style Manual override (2) 150/30 m/s2 Shock/Vibration resistance Dust proof Enclosure 12V, 24V DC 100V, 110V, 200V, 220V AC 10% of rated voltage Coil rated voltage Allowable voltage Class B Coil insurance 1W DC (42mA), 0.5W DC (21mA) 24V DC 1W DC (

.;,1 '"1 , ,"1 20 40 60 Flow rate (l/min (ANR)) a' e 6 E .9 .t 0.0 . 3 o 20 40 60 80 1 Frow rale (l/min (ANa)) Series lTV201n Hysteresis Repeatability Linearity i .9 .g o 25 50 75 100 Inpll signal (%F.S.) 25 50 75 r00 Inputsignal (%F.S.)

Normally Closed o SERIES NVF 110 DIRECTIONAL AIR VALVE DIRECT SOLENOID OPERATED CHARACTEFISTICS Port Sizss (NPTO '10-32 P&E; 10-32 or 1/8"A Opelating Prsssure 0'100 PSI; 0-150 PSI (H) ftoof Pre6sur 225 PSIG (15Kgflcm'z) Operailng Temperature 14-140'F(101o + 6O"C) a;a lnrusn s.6 VA (50 Hz),5.0 VA(60 Hz) Holding 3.4 VA (50 Hz),2.3 VA (60 Hz) PowerConaumptlon DC 1 . 8 W c, 0.055 , 0.05 (H Type

t 0s6 (%6') lele 2% 075 (%\ l ela 2/a 106 (1I6',1 131 216 -, Bore Stroke t 150 \1y2\ 13/4 2% 20o (2\ 11%6 2%a 106 (1'16') lia l=0.52 150 {1%") 114 l=0.5 250l2%\ 23la 3146 300 (3) 2% 3% 400 (4'l 2sla 3?/16 NOTE 1) Female threacl length ("1") is shoner for iie above listed strokes.

(packaged together) 50 80 650 F 40 550 G 10 300 H 4 200 J Filter (IN port) Nil Without filter F With filter Note) 100 Note) Flow reduction rate 50 L/min: 5% or less 100 L/min: 5 to 10% 150 L/min: 10 to 15% 80 600 K 40 500 L 10 250 M 4 150 150 Specifications Flow rate (L/min) [at 0.25 MPa] 50 100 150 Power consumption (W) 80 40 10 4 80 40 10 4 80 40 10 4 Type of actuation 2-position 2 port

t 0s6 (%6') lele 2% 075 (%\ l ela 2/a 106 (1I6',1 131 216 -, Bore Stroke t 150 \1y2\ 13/4 2% 20o (2\ 11%6 2%a 106 (1'16') lia l=0.52 150 {1%") 114 l=0.5 250l2%\ 23la 3146 300 (3) 2% 3% 400 (4'l 2sla 3?/16 NOTE 1) Female threacl length ("1") is shoner for iie above listed strokes.

Cushion adjustment (Relief adjustment) man-hours are the same as the adjustment (cushion needle adjustment) for general purpose cylinders. 350 High power cylinder 300 General purpose cylinder (SMC Series CG1) Buffer capacity [kgf cm] Quality of cushioning (RHCF40-500, Load weight 5kg, Supply pressure 0.5MPa, Horizontal operation) 250 500 3000mm/s 1000mm/s 2000mm/s 200 500mm/s 400 150 Deflection

The graphs below show the variation of the distance for the product to turn ON, for 3 types of gap, by changing the supply pressure (50 kPa) when the product is set to turn ON at 150 kPa supply pressure. Detection nozzle: 1.5 Piping: F type: 4 x 2.5 tube Test conditions G, H type: 6 x 4 tube Reference pressure: 150 kPa : Use within the rated pressure range (100 kPa to 200 kPa).