SMC Corporation of America
Elite Part Number Search
Search Results "S070B-VAC-M3"

S With flow restrictors for additional air flow at two positions *3: The AC power supply cable attached to the product has the configuration applicable to socket of 100 VAC.The cap needs to be changed when the cable is connected to a socket of voltage other than 100 VAC.

.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Voltage 2 2 4 4 15 10 250 VAC 1.5 1.5 3 3 15 10 8 VDC 1.5 2.5 3 5 15 15 14 VDC 1.5 2.5 3 5 15 10 30 VDC 1.5 2.5 3 5 6 5 125 VDC 0.3 0.05 0.3 0.05 0.5 0.05 250 VDC 0.2 0.03 0.2 0.03 0.25 125 VAC 15 15 15 15 6 0.5 0.25 0.03 10 10 15 10 5 0.05 0.03 JIS Symbol

Bolt Max. tightening torque [lbfft] Model LEPY6 LEPS6 LEPY10 LEPS10 M3 x 0.5 0.66 It may damage and malfunction. If the operation is interrupted or stopped during the cycle: When the pushing operation command is output immediately after restarting the operation, the direction of movement depends on the position of restart. M4 x 0.7 1.03 Side mounting (Body tapped) 2.

Low Voltage Directive This directive is applied to products, which operate above 50 VAC to 1000 VAC and 75 VDC to 1500 VDC operating voltage, and require electrical safety measures to be introduced. Simple Pressure Vessels Directive This directive is applied to welded vessels whose maximum operating pressure (PS) and volume of vessel (V) exceed 50 bar/L.

Actuation: 1 (2 Position Single Solenoid), Piping/EXH: 23 (Body Ported/Common Exhaust), Coil Specification: Standard, Voltage: 3 [110 VAC, (115 VAC)], Electrical Entry: G (Grommet, Lead Wire 300mm), Light/Surge Voltage Suppressor: Z (w/ Light/Surge Voltage Suppressor), Manual Override: Non-locking Push Type, Port Size: M3 (Body Ported), Bracket: F (w/Bracket)

Actuation: 1 (2 Position Single Solenoid), Piping/EXH: 23 (Body Ported/Common Exhaust), Coil Specification: Standard, Voltage: 4 [220 VAC, (230 VAC)], Electrical Entry: G (Grommet, Lead Wire 300mm), Light/Surge Voltage Suppressor: Z (w/ Light/Surge Voltage Suppressor), Manual Override: Non-locking Push Type, Port Size: M3 (Body Ported), Bracket: F (w/Bracket)

Actuation: 1 (2 Position Single Solenoid), Piping/EXH: 23 (Body Ported/Common Exhaust), Coil Specification: Standard, Voltage: 3 [110 VAC, (115 VAC)], Electrical Entry: MO (M Plug Connector, w/o Connector), Light/Surge Voltage Suppressor: w/o Light/Surge Voltage Suppressor, Manual Override: Non-locking Push Type, Port Size: M3 (Body Ported), Bracket: F (w/Bracket)

Actuation: 1 (2 Position Single Solenoid), Piping/EXH: 23 (Body Ported/Common Exhaust), Coil Specification: Standard, Voltage: 3 [110 VAC, (115 VAC)], Electrical Entry: L (L Plug Connector, Lead Wire 300mm), Light/Surge Voltage Suppressor: w/o Light/Surge Voltage Suppressor, Manual Override: Non-locking Push Type, Port Size: M3 (Body Ported), Bracket: F (w/Bracket)

Actuation: 1 (2 Position Single Solenoid), Piping/EXH: 23 (Body Ported/Common Exhaust), Coil Specification: Standard, Voltage: 3 [110 VAC, (115 VAC)], Electrical Entry: LO (L Plug Connector, w/o Connector), Light/Surge Voltage Suppressor: w/o Light/Surge Voltage Suppressor, Manual Override: Non-locking Push Type, Port Size: M3 (Body Ported), Bracket: F (w/Bracket)

Actuation: 1 (2 Position Single Solenoid), Piping/EXH: 23 (Body Ported/Common Exhaust), Coil Specification: Standard, Voltage: 4 [220 VAC, (230 VAC)], Electrical Entry: L (L Plug Connector, Lead Wire 300mm), Light/Surge Voltage Suppressor: w/o Light/Surge Voltage Suppressor, Manual Override: D (Push-turn Locking Slotted Type), Port Size: M3 (Body Ported), Bracket: F (w/Bracket)

Actuation: 1 (2 Position Single Solenoid), Piping/EXH: 23 (Body Ported/Common Exhaust), Coil Specification: Standard, Voltage: 4 [220 VAC, (230 VAC)], Electrical Entry: LN (L Plug Connector, w/o Lead Wire), Light/Surge Voltage Suppressor: Z (w/ Light/Surge Voltage Suppressor), Manual Override: D (Push-turn Locking Slotted Type), Port Size: M3 (Body Ported)

Actuation: 1 (2 Position Single Solenoid), Piping/EXH: 23 (Body Ported/Common Exhaust), Coil Specification: Standard, Voltage: 4 [220 VAC, (230 VAC)], Electrical Entry: LO (L Plug Connector, w/o Connector), Light/Surge Voltage Suppressor: w/o Light/Surge Voltage Suppressor, Manual Override: Non-locking Push Type, Port Size: M3 (Body Ported)

. -14No.PF-OMN0012-H Mounting and Installation Installation Mounting with panel mount adapter Fix the panel mount adapter to the flow monitor with the screws supplied M3 x 8 L (2 pcs.).

Table 3-1 Amount of radiation and required ventilation Required ventilation amount m3/min Differential temp. of 3 oC Differential temp. of 6 oC Heat Radiated between inside and between inside and Model kW outside of installation outside of installation area area HRS018-A-20--R Approx. 4 70 40 HRS030-A -20--R Approx. 6 100 60 3.2 Installation HRS-R Series 3-6 HRX-OM-W058 Chapter 3 Transport

Table 3-1 Amount of radiation and required ventilation Required ventilation amount m3/min Differential temp. of 3 oC Differential temp. of 6 oC Heat Radiated between inside and between inside and Model kW outside of installation outside of installation area area HRS050-A-20--R Approx. 10 140 70 3.2 Installation HRS-R Series 3-6 HRX-OM-X027 Chapter 3 Transport and Setting Up 3.2.3 Installation

. -11No.EX-OMI0001-I Common Specifications EX510 series common specifications Item Specification Rated voltage 24 VDC 1 Allowable instantaneous electrical stop 1 msec. or less Enclosure IP20 Applicable standard UL/CSA, CE marked Withstand voltage 500 VAC 1 minute (between FG and external terminal block) Insulation resistance 10 M or more (500 VDC is given between FG and external terminal

Tighten the FG terminal (M3 round head combination screw) firmly with a tightening torque of 0.3 Nm. Tighten the connector fixing screws (M2.5 slotted head screws) firmly with a tightening torque of 0.2 to 0.3 Nm. A. Dual power supplies B. Single power supply Figure 3 Figure 4 : Communication connector FG and FG terminal are connected inside the SI unit.

Operation display panel For power supply of 100 V specifications, connect the plug to the outlet of 100 VAC (50/60 Hz). For power supply of 200 V specifications, connect the plug to the breaker (recommended size: 15 A) of the user's equipment. Power supply cable Model label Shows the part number of the product. For details, refer to section 1.4.1 Product Label.

(no condensation) Withstand voltage 1000 VAC, 1 min. between terminals and case Insulation resistance 50 M min.

Mount with the set screws M3 size (2 pcs.) supplied for direct installation. The required tightening torque of the mounting screws is 0.5 to 0.7 Nm. Mounting with panel mount adapter Panel mount adapter + Front protective cover (Model: ZS-39-D) -15No.PS-OMM0005-J Removal and mounting on DIN rail It is necessary to prepare a DIN rail adapter for the mounting on the DIN rail.