operation Power supply for solenoid valve Residual voltage 0.4 VDC or less Network communication specifications Item Specifications Protocol Ethernet POWERLINK Transmission medium Standard Ethernet cable (CAT5 or more) (100BASE-TX) Transmission speed 100 Mbps Transmission method Half duplex Node ID setting method Rotary switch : from 1 to 239 EX260-SPL1 32 outputs Number of outputs EX260
Rated voltage 5 6 24 VDC 12 VDC Note) Latching type: 24 VDC only Standard Specifications Standard single type (2W) Large-flow single type (3.2WEnergy saving type) Large-flow latching type (2W) 4 port direct operated poppet valve Air/Inert gas 0.7 MPa 0 MPa / 101.2 kPa Type Item Valve construction Fluid Maximum operating pressure Minimum operating pressure/Vacuum Response time(1) Valve specifications
) 100 or less (at 12 VDC) Brown DC (+) Load Main circuit Main circuit (Analog output) 1 k Black OUT + + 12 to 24 VDC 12 to 24 VDC Blue LINE () Load Blue DC () Load Install the load either on the LINE (+) or LINE () side.
CC Turbine oil of ISO VG32 (Example)
CC Turbine oil of ISO VG32 (Example)
LQ Thread type Nil T F N For 32A For 40A For 50A 32 40 50 Rc NPTF G NPT Flange LVN Refer to the table (1) given below for availability.
12 VDC Nil Thread type 6 VDC Rc 5 VDC F N G 3 VDC NPT Please consult with SMC regarding other voltages.
supplies for logic/input and output) Operating voltage range 24 VDC +10%/-10% For logic/input Under-voltage detection approx. 16.8 VDC For output Operating voltage range 24 VDC +10%/-5% Isolation Yes (Between power supplies for logic/input and output) Fieldbus Bus protocol IO-Link Version 1.1 IO-Link type Device IO-Link Port Class Class B Transmission rate COM2 (38.4 kbps) Firmware update
11LEJS Miniature Slide Table Type LEPS Series 25AStep Motor (Servo/24 VDC) LEC LEC S LEC SS-T LEC Y Motorless LAT LZ LC3F2 373 Step Motor (Servo/24 VDC) Electric Actuator/Miniature Rod Type LEPY Series Model Selection LEPY SeriessPage 378 Selection Procedure Positioning Control Selection Procedure Step 1 Check the work loadspeed.
Analog output Current output 4 to 20 mA Linearity: 5% F.S. or less; allowable load resistance: 300 or less with 12 VDC, 600 or less with 24 VDC 12 to 24 VDC (ripple 10% or less) Power supply voltage 20 mA or less Current consumption (No load) Enclosure IP65 Operating temperature range Operating: 0 to 50C, Stored: 25 to 85C (with no freezing and condensation) Withstand voltage 1000 VAC for
to 24 VDC 12 to 24 VDC Load Load Load White OUT2 White OUT2 Load Blue DC () Blue DC () -R: NPN (2 outputs) + Auto-shift input -S: NPN (2 outputs) + Auto-shift input -T: PNP (2 outputs) + Auto-shift input -V: PNP (2 outputs) + Auto-shift input Brown DC (+) Brown DC (+) Load Gray Auto-shift input Gray Auto-shift input Load + + Black OUT1 Black OUT1 12 to 24 VDC 12 to 24 VDC Load Load White
Relay Circuit Example Open-collector Circuit Example DRIVER DRIVER 24 VDC +24 VIN 3.3 k +24 VIN 3.3 k 24 VDC /DEC, etc. /DEC, etc. Note: The 24 VDC external power supply capacity must be 50 mA minimum. The DRIVERs input circuit uses bidirectional photocoupler. Select either the sink circuit or the source circuit according to the specifications required for each machine.
Problem Problem possible causes Investigation method Countermeasures Check that the power supply voltage is within the range 12 to 24 VDC 10%. Supply the correct voltage of 12 to 24 VDC 10%. Incorrect power supply Check the wiring to the power supply.
Problem Problem possible causes Investigation method Countermeasures Check that the power supply voltage is within the range 12 to 24 VDC 10%. Supply the correct voltage of 12 to 24 VDC 10%. Incorrect power supply Check the wiring to the power supply.
less 50 mA, 40 mA, 20 mA IC circuit, Relay, PLC No Reed auto switch D-A90 D-M9B, D-F8B D-M9N, D-F8N 2-wire 3-wire 24 VDC relay, PLC 24 VDC relay, PLC Solid state auto switch Yes 24 VDC (10 to 28 VDC) 24 VDC (4.5 to 28 VDC) Yes 2.5 to 40 mA 40 mA or less Refer to page 920 for the applicable auto switch list. 909 Rotary Table MSQ 1122Specifications Suction Flow Rate of Vacuum Suction Type
A 24 VDC 4 15A N.C. F C37 1/2 15 G Stainless steel B 100 VAC Grommet With surge voltage suppressor C 110 VAC 5 20A N.C. H C37 3/4 20 J Stainless steel D 200 VAC E 230 VAC 6 25A N.C.
1/8 One-touch tube fitting Inch size LN3 Elbow type 5/32 One-touch tube fitting 34 - Doc. no.
DC specifications 5 6 V S R Magnet installed even without auto switch Symbol A B 24 VDC 12 VDC 6 VDC 5 VDC 3 VDC 100 VAC 200 VAC 110 VAC (115 VAC) 220 VAC (230 VAC) Auto switch mounting Rail mounting style Band mounting style Example Rail mounting style Band mounting style CDVJ5B15-60-A CDVJ5B10-45-B For the applicable auto switch model, refer to the table below.