SMC Corporation of America
Elite Part Number Search
Search Results "S070M-VDC-32"

Relay Circuit Example Open-collector Circuit Example DRIVER DRIVER 24 VDC +24 VIN 3.3 k +24 VIN 3.3 k 24 VDC /DEC, etc. /DEC, etc. Note: The 24 VDC external power supply capacity must be 50 mA minimum. The DRIVERs input circuit uses bidirectional photocoupler. Select either the sink circuit or the source circuit according to the specifications required for each machine.

Problem Problem possible causes Investigation method Countermeasures Check that the power supply voltage is within the range 12 to 24 VDC 10%. Supply the correct voltage of 12 to 24 VDC 10%. Incorrect power supply Check the wiring to the power supply.

: 11 to 25 VDC Power supply for the solenoid valves: 24 VDC +10/-5% Current consumption Communication power supply for DeviceNetTM: 0.1 A or less Power supply for the solenoid valves Output type EX180-SDN3#/4#: NPN (positive common)/sink EX180-SDN5#/6#: PNP (negative common)/source Output specification Number of outputs EX180-SDN3#/5#: 32 points EX180-SDN4#/6#: 16 points Connection load Solenoid

Compatible PLC Manufacturers 32 inputs 32 inputs 64 outputs OMRON Corporation Mitsubishi Electric Corporation Sharp Corporation KEYENCE CORPORATION 24 VDC Power supply Direct connected branch unit Note) Applicable e-con type PLC manufacturers: OMRON Corporation, Mitsubishi Electric Corporation e-con 16 point branch unit (with cover) e-con 8 point unit (with cover) e-con 8 point unit (circuit

Socket Hook Data 10-15-3 Valve Mounted Cylinder Single Acting, Single Rod, Spring Return/Extend Series CVM3 20, 25, 32, 40 How to Order RE A B Bore size Solenoid valve voltage 20 25 32 40 REC 20 mm 25 mm 32 mm 40 mm Standard Option 1 2 5 Mounting style 3 4 6 9 100 VAC (50/60 Hz) 110 VAC (50/60 Hz) 220 VAC (50/60 Hz) 12 VDC Other CX Basic style Axial foot style Rod side flange style Head

Refer to the table for each pressure specification (page 110) Display/set pressure range Display/min. setting unit Power supply Used as switch output device 12 to 24 VDC (10%), and voltage ripple (p-p) 10% at max. voltage Used as IO-Link device 18 to 30 VDC, including ripple (p-p) 10% Electric spec. Power supply voltage 12 to 24 VDC (10%), and ripple (p-p) 10% at max.

, 600 or less with 24 VDC output Power supply voltage 12 to 24 VDC 10% Current consumption 20 mA or less (without load) Enclosure IP65 Environmental resistance Operating temperature range Operating: 0 to 50C, Stored: 25 to 85C in stock (with no condensation and freezing) Voltage resistance 1000 VAC for 1 min. between external terminals and case Insulation resistance 50 M or more (500 VDC

Electrical specifications Item Specifications Current consumption of controller power supply 21.6 to 26.4 VDC 0.1 A max.

DC EZ, TZ, DZ, YZ (100 VDC or more) EZ, TZ, DZ, YZ (100 VDC or more) Z EZ, TZ, DZ, YZ (24 VDC or less) Note) W/ surge voltage suppressor is available only for grommet type. 4-8-3 4 Series VP300/500/700 Precautions Be sure to read before handling. For Safety Instructions and Solenoid Valve Precautions, refer to page 4-18-2. Caution Change of Actuation Caution How to Use DIN Terminal 1.

OUT(2) 1 Thread type Rc NPT G Nil N F IN(1) Voltage 1 2 3 4 5 6 36 100 VAC 200 VAC 110 VAC 220 VAC 24 VDC 12 VDC 230 VAC Port size Class 3 Port size 1/8 (6A) 1/4 (8A) Class 2 Class 4 Symbol 01 02 03 04 06 3/8 (10A) 1/2 (15A) Class B in AC has a rectifying circuit built-in. Class H is AC only. No rectifying circuit.

Incorrect power supply Check if the power supply voltage is in the range 12 to 24 VDC 10%. Supply power in the range 12 to 24 VDC 10%. Check the power supply wiring. Check if the brown and blue wires are connected to DC(+) and DC(-) respectively, and if the wiring is secure. Check and correct the wiring. Incorrect wiring 7 The display is unstable.

Setting of the response time may improve the condition. -86No.PF-OMX0002-B Error indication Problem Possible causes Investigation method Countermeasure Incorrect power supply Check if the power supply voltage is 24 VDC 10%. Power supply voltage is 24 VDC 10%.

One branch of manifold valves/input unit can be connected to 32 outputs/32 inputs. Up to 4 branches can be connected (total 128 outputs/128 inputs). No.

One branch of manifold valves/input unit can be connected to 32 outputs/32 inputs.

Indicator light Output 1 and 2: Orange Power supply Used as switch output device 12 to 24 VDC, including ripple (p-p) 10% voltage Used as IO-Link device 18 to 30 VDC, including ripple (p-p) 10% Current consumption 50 mA max.

Piping Specifications Part N7L C6L C4L N7H C6H C4H T1 01 NPT 1/8 M5 x 0.8 R 1/8 M5 x 0.8 Port size One-touch fitting Straight type 4 mm 5/32 inch 1/4 inch 6 mm One-touch fitting Elbow type 4 mm 5/32 inch 1/4 inch 6 mm Sensor pressure receiving area: Silicon, Piping port: C3602 (Electroless nickel plated), O-ring: HNBR Wetted part material O-ring: NBR, fitting: PBT O-ring: NBR With lead

Series VXH 2 3 4 Class 2 Class 3 Class 4 Material and insulation type VXF Symbol Nil D H N Coil insulation type Seal material Body material Class B Class H Class B Class H Stainless steel Brass (C37) Valve type VX3 FKM N.C. 2 VXA 1 Thread type VCHm 1 Rc NPT G Nil N F VDW Voltage 1 2 3 4 5 6 7 8 J 100 VAC 200 VAC 110 VAC 220 VAC 24 VDC 12 VDC 240 VAC 48 VAC 230 VAC VQ Port size LVM Class B

12 VDC 230 VAC All types equipped with surge voltage suppressor.

Green Between case and AC line: 500 VDC, 50 Mor more GND 32 to 122F (0 to 50C) (No freezing) Ambient temperature F.G.