size) ASV 4 6 6 10 8 4 Flow rate [L/min (ANR)] It may damage the body A or fittings. 100 130 230 290 660 920 AK Controlled flow Body A Free flow Sonic conductance [dm3/(sbar)] 0.28 0.36 0.64 0.8 1.8 2.6 VCHC Controlled flow Free flow 0.2 0.25 0.2 0.25 0.2 0.25 0.2 0.25 Caution Release from One-touch fitting Critical pressure ratio ASR ASQ Note) Flow rate values are measured at 0.5 MPa and 20C
10 12 4 JIS Symbol Tubing O.D. 1 8" 3 16" 1 4" 1 4" 5 16" 5 16" , 3 8" , 5 32" 3 16" 1 4" 5 16" 3 8" 3 8" " 1 2 Inch size 5 32" Flow rate (/min (ANR)) 260 390 660 790 920 1580 180 230 460 1710 Flow Direction Symbols on Body Controlled flow (Free flow) Meter-out type Meter-in type Effective area (mm2) 4 6 10 12 14 24 2.7 3.7 7 26 Symbol Note 1) Flow rate values are measured at 0.5 MPa and 20C
AS1001F AS2001F AS3001F AS2051F AS4001F Model 3.2, 4, 6 4 6 6 8 6 8 10, 12 10 12 Metric size Tubing O.D. 1/8" 5/32" 3/16", 1/4" 3/16" 1/4" 1/4" 5/16" 3/16" Inch size 1/4" 5/16" 3/8" 3/8" 1/2" 5/32" Flow rate (l/min(ANR) 290 460 230 100 130 420 660 920 1050 1390 Controlled flow (Free flow) 4.5 7 3.5 1.5 2 6.5 10 14 16 21 Effective area (mm2) Note) Flow rate values are measured at 0.5 MPa and 20C
Metric size 4 4 6 230 260 390 460 660 790 920 1580 1710 Flow rate (/min (ANR)) 180 Controlled flow (Free flow) Flow Direction Symbols on Body Effective area (mm2) 2.7 3.5 4 6 7 10 12 14 24 26 Meter-out type Meter-in type Note) Flow rate values are measured at 0.5 MPa and 20C.
(mm) Effective area (mm2) Weight (g) Port size Flow rate (/min (ANR)) Flow rate (/min (ANR)) Flow rate (/min (ANR)) AS2000E-01 AS2000E-02 AS3000E-02 AS3000E-03 AS4000E-02 AS4000E-03 AS4000E-04 90 1/8 1/4 1/4 3/8 1/4 3/8 1/2 340 5.2 250 3.8 20, 25, 32, 40 115 32, 40, 50, 63 810 12.3 810 12.3 130 40, 50, 63 80, 100 1670 25.5 1670 25.5 225 Note) Flow rate values are measured at 0.5 MPa and 20C
Metric sizes 6 8 10 12 ASS Flow rate l/min (ANR) Controlled 100 180 230 260 390 460 660 790 920 1580 1710 ASR (free) flow Effective area mm2 1.5 2.7 3.5 4 6 7 10 12 14 24 26 Note) Flow rate values are at a pressure of 0.5MPa, and temperature of 20C.
Critical pressure ratio AS420-02 AS420-03 AS420-04 AS500-06 AS600-10 AS800-12 AS900-14 AS900-20 1/4 3/8 1/2 3/4 1 1 1 2 10 13.3 18.6 22.5 47 107 132 169 3,600 4,800 6,700 8,100 16,900 38,500 47,500 60,800 6.9 13.9 18.3 28.1 42 98 144 161 2,500 5,000 6,600 10,100 15,100 35,400 52,000 57,800 0.34 0.33 0.32 0.36 0.7 1.4 3.3 3.3 0.45 0.25 1 4 1 2 Note) Flow rate values are measured at 0.5 MPa and 20C
/4", Inch size 3/16" 1/4" 5/16" 3/8" 3/8" 1/2" 5/32" 5/16" VCHC Flow rate (L/min(ANR)) Controlled flow Free flow 230 460 100 130 290 420 660 920 1050 1390 Sonic conductance (dm3/(sbar)) ASR ASQ 0.64 1.3 0.28 0.36 0.8 1.2 1.8 2.6 2.9 3.9 Critical pressure ratio Symbol Controlled flow 0.2 0.2 0.2 0.2 0.2 Free flow 0.25 0.25 0.25 0.25 0.25 Note) Flow rate values are measured at 0.5 MPa and 20C
0.06 20 0.06 20 M3 x 0.5 4.7 0.15 0.22 80 0.25 90 M5 x 0.8 33 0.7 250 0.94 340 1/8 90 0.7 250 0.94 340 1/4 115 2.3 810 2.3 810 1/4 130 2.3 810 2.3 810 3/8 124 0.2 4.6 1,670 4.6 1,670 1/4 221 0.35 4.6 1,670 4.6 1,670 3/8 214 4.6 1,670 4.6 1,670 1/2 205 7.9 2,840 7.9 2,840 1/4 242 11.9 4,270 11.9 4,270 3/8 233 11.9 4,270 11.9 4,270 1/2 224 Note) Flow rate values are measured at 0.5 Mpa and 20C
temperature Round lock nut With seal, Round lock nut, Nickel plated Option Weight (g) 181 106 64 29 10 6 3 Flow rate L/min (ANR) 105 230 460 920 1700 20 Controlled flow Free flow Sonic conductance dm 3/(sbar) 0.32 0.7 1.4 2.8 5.2 0.06 Critical pressure ratio Controlled flow 0.2 0.25 0.3 0.25 0.25 0.2 Free flow 0.4 0.2 0.3 0.2 0.3 0.4 Note 1) Flow rate values are measured at 0.5 MPa and 20C
Sulfuric acid (30%, Room temperature) 4 Phosphoric acid (50%, Room temperature) 5 CY Ammonium hydroxide (28%) 6 MQQ M Inorganic alkali Sodium hydroxide (30%, Room temperature) 7 Calcium hydroxide 8 RHC Magnesium hydroxide 9 Acetylene 10 MK(2) 11 Formic acid (25%, Room temperature) Organic solvent 12 Citric acid RS Q G 13 Acetic acid (10%, Room temperature) RS H A Lactic acid (5%, 20C
-X Body option Nil M Standard (Rod end female thread) Rod end male thread Cushion 20C Rubber bumper Piping Data Action Screw-in piping Built-in One-touch fittings Note) Nil F D Double acting Note) Bore sizes available w/ One-touch fittings are 32 to 63. Cylinder stroke (mm) Refer to Standard Stroke on page 7-6-122.
(Coil temperature: 20C, at rated voltage, without surge suppressor) Note 2) Impact resistance: No malfunction occurred when it is tested with a drop tester in the axial direction and at the right angles to the main valve and armature in both energized and de-energized states every once for each condition.
(Coil temperature: 20C, at rated voltage, without surge suppressor) Note2) Impact resistance: No malfunction occurred when it is tested with a drop tester in the axial direction and at the right angles to the main valve and armature in both energized and de-energized states every once for each condition.
(Coil temperature: 20C, at rated voltage, without surge suppressor) Note 2) Impact resistance: No malfunction occurred when it is tested with a drop tester in the axial direction and at the right angles to the main valve and armature in both energized and de-energized states every once for each condition.
(Coil temperature: 20C, at rated voltage, without surge voltage suppressor) Note 2) This solenoid valve requires lubrication. Use turbine oil Class 1 (ISO VG32).
It is strongly recommended to use clean dry air (with a dew point at approximately -20C). 4. Air connections should only be made with the pressure supply turned off. Flush the system before piping to prevent foreign matter from entering inside the product. 499
ANR: 20C at atmospheric pressure, relative humidity 65% 1 mg/m 3 (ANR) 0.8 ppmW/W Note 2) If there is a special law under operation, the law has ultimate priority. Note 3) It describes the grade of compressed air quality based on ISO8573-1: 1991 and JIS B 8392-1: 2000. (Refer to table on top in following page.)
(Inlet air pressure: 0.7 MPa, Inlet air temperature: 20C) HA How to Order AT ID 20 02 0 ID AMG ID400 Option B Bracket Z Adsorbent for low dew point Basic size AFF 20 30 40 60 Port size AM ID200 02 B 04 06 1 4 B 1 2 B 3 4 Nil Rc Thread type Misc.
Based on condition y; IDFS11E is selected as the model to process an air flow larger than 1400 l/min (ANR) with a 60Hz power supply, according to data D-2. 4 4 Note) l/min (ANR) is for reference conditions of 20C, 1 ATM and 65% relative humidity. Data A: Correction Factor for Temperature (Series IDUS) Inlet air temp. (C) Outlet air press. dew point (C) Ambient temp.