Kit components main parts MIS12-10D MI-A1201-10 MI-A1202-10 MI-A1203-10 MIS12-20D MI-A1201-20 MI-A1202-20 MI-A1203-20 MIS12-30D MI-A1201-30 MI-A1202-30 MI-A1203-30 MIS20-10D MI-A2001-10 MI-A2002-10 MI-A2003-10 MIS20-20D MI-A2001-20 MI-A2002-20 MI-A2003-20 MIS20-30D MI-A2001-30 MI-A2002-30 MI-A2003-30 Standard Finger Tapped on upper and lower faces Tapped on all faces 3 12 13 14 20 Seal kit
End Lock Specifications Model MXS8 MXS12 MXS16 MXS20 MXS25 8 12 16 20 25 Bore size (mm) 2-20 in/s (50~500m/s) Operating speed range 5.62 13.5 24.7 36.0 56.2 Holding force (lbf) 1 lbf = 4.4482 N Note) Refer to P. 14 for cautions on end lock.
12 13 11 14 Parts List Note Material No.
20 14 44 52 64 77 40 46 58 12 16 16 10 11 13 16.5 27 32 39 44 47 50 14 54 64 78 6.5 6.8 7.5 14 19 19 4 7 6.5 40 50 63 25, 50, 75, 100, 125, 150 175, 200, 250, 300, 350 107 M8 39.5 14 44 11 12 115 M10 46 16.5 49 13.5 16.5 WA Bore size (mm) ML S T U VA OA OB OL P PA PB PW Q R VB MM NN st25 25
20 14 44 52 64 77 40 46 58 12 16 16 10 11 13 16.5 27 32 39 44 47 50 14 54 64 78 6.5 6.8 7.5 14 19 19 4 7 6.5 40 50 63 25, 50, 75, 100, 125, 150 175, 200, 250, 300, 350 107 M8 39.5 14 44 11 12 115 M10 46 16.5 49 13.5 16.5 WA Bore size (mm) ML S T U VA OA OB OL P PA PB PW Q R VB MM NN st25 25
BA 0 0.3 CA BA 0 0.3 Drawing of view E Bore size (mm) S NA Z NB H CA GA BA CB GB 14.5 4.5 1.6 24 6 15 15 3 8 12 11 28 17 24.5 7 85.5 M3 x 0.5 14 32 57.5 T 3 M8 x 1.0 NN FB FC FT FX MM FY FZ GC F D BB A 20.5 20.5 9.5 9.5 83 82 M5 x 0.8 M4 x 0.7 55 54 M12 x 1.0 M10 x 1.0 28 28 17 20 5 5 16 10 15 15 18.3 15 18.3 12 20 14 5 4 8 8 5 5 11 11 17.5 19 5.5 5.5 2.3 2.3 33 33 20 20 42 42 With air
23 15 23 15 23 15 23 15 48 48 48 48 12 12 12 12 20 20 20 20 54.5 54.5 54.5 54.5 57.6 Refer to page 646 for dimensions with connector cable. 631 Series 10-SYJ700 Manifold Specifications [Option] Directional Control Valves Air Grippers Modular F.
Level Range> Without Load 800 Lead 4: LEY32C Model Pushing speed [mm/s] Pushing force (Setting input value) Model Pushing speed [mm/s] Pushing force (Setting input value) 700 Lead 8: LEY32B 1 to 4 20% to 65% 1 to 4 40% to 95% 600 LEY25 LEY25A 5 to 20 35% to 65% 5 to 20 60% to 95% Lead 16: LEY32A 500 21 to 35 50% to 65% 21 to 35 80% to 95% Force [N] 1 to 4 20% to 85% 400 LEY32 5 to 20 35%
14 19 22 14 19 22 30 30 40 48 30 40 48 15 15 20 24 15 20 24 62.5 73.5 72 75 78 76.5 79.5 30 35 35 35 40 40 40 9 9 9 20 22 22 22 24.5 24.5 24.5 8 8 9 14 8 9 14 15 15 22.2 19 15 22.2 19 18 18 22.2 20.6 18 22.2 20.6 6.4 6.4 7.6 6 6.4 7.6 6 47.5 50 50 50 52.5 52.5 52.5 38 47.5 46 47 52 50.5 51.5 23 25.5 25.5 25.5 28 28 28 44 54 52.5 53.5 58 56.5 57.5 VX2 2 11 9 9 3 11 13 Series VXN Air, Water
If using other screws, switch may be damaged. (3) Load current range and Maximum load current 5 to 20 mA 5 to 40 mA 20 mA Contact protection circuit None D-A93 2.4 V or less (up to 20 mA)/3 V or less (up to 40 mA) D-A93V 2.7 V or less Internal voltage drop 0.8 V or less Auto Switch Internal Circuit Colors of lead wire inside ( ) are the ones before conformed to IEC standard.
If using other screws, switch may be damaged. (3) Load current range and Maximum load current 5 to 20 mA 5 to 40 mA 20 mA Contact protection circuit None D-A93 2.4 V or less (up to 20 mA)/3 V or less (up to 40 mA) D-A93V 2.7 V or less Internal voltage drop 0.8 V or less Auto Switch Internal Circuit Colors of lead wire inside ( ) are the ones before conformed to IEC standard.
If using other screws, switch may be damaged. (3) Load current range and Maximum load current 5 to 20 mA 5 to 40 mA 20 mA Contact protection circuit None D-A93 2.4 V or less (up to 20 mA)/3 V or less (up to 40 mA) D-A93V 2.7 V or less Internal voltage drop 0.8 V or less Auto Switch Internal Circuit Colors of lead wire inside ( ) are the ones before conformed to IEC standard.
[C] HRS100-W-20/40(60 Hz) HRS100-W-20/40(50 Hz) 14 14 Facility water temperature 32C 12 12 Cooling capacity [kW] Cooling capacity [kW] Facility water temperature 32C 10 10 8 8 6 6 4 4 Facility water temperature 40C Facility water temperature 40C 2 2 0 0 5 10 15 20 25 30 35 5 10 15 20 25 30 35 Circulating fluid temperature [C] Circulating fluid temperature [C] HRS150-A-20/40(50 Hz) HRS150-
VXZ Height Weight Class H/24 VDC Class H/DIN terminal Seal material: EPDM 7%Smaller 20%Lighter VXS (90 g) (7 mm) Approx.
Note 3) Note 6) Vertical Basic 0.5 0.25 1.5 1.0 Compact 1.5 1.0 Actuator specifications Horizontal Basic 10 to 150 20 to 300 Note 4) 10 to 200 20 to 350 Note 4) Compact 10 to 200 20 to 350 Note 4) Speed [mm/s] Note 3) Note 6) Vertical Basic 10 to 150 20 to 300 Note 4) 10 to 150 20 to 300 Note 4) Compact 10 to 150 20 to 300 Note 4) Pushing speed [mm/s] Note 5) 10 20 10 20 Acceleration
75 14 73 150 M8 x 1.25 162 W Y WH X Z Bore size (mm) 20 25 32 40 30 23 30 146 182 30 25 37 167 199 25 28.5 37 167 202 20 33 44 210 227 Without Rear Plate Stroke range (mm) Long Stroke Bore size (mm) 20 25 32 40 Bore size (mm) 20 25 32 40 Z R Y 250 to 400 190 14 129 350 to 500 207 14 146 350 to 600 210 14 146 350 to 800 236 15 191 Note) Dimensions marked with are not required for the one
25 73 70 150 M8 x 1.25 162 W WH X Y Z Bore size (mm) 20 25 32 40 30 23 30 146 182 30 25 37 167 199 25 28.5 37 167 202 20 33 44 210 227 Without Rear Plate Stroke range (mm) Long Stroke Bore size (mm) 20 25 32 40 Bore size (mm) 20 25 32 40 R Z Y 250 to 400 14 190 129 350 to 500 207 14 146 350 to 600 14 210 146 350 to 800 15 236 191 Note) Dimensions marked with are not required for the one
L FT FX B + Stroke (mm) FZ FX A + Stroke Bore size (mm) Stroke range (mm) FZ A B CL CD CT CU 10 10 to 40 61.5 90.5 84.5 5 4 10 Double clevis type: MQQLD 16 10 to 60 70.5 107.5 98.5 8 5 12 20 10 to 60 79 119 109 10 5 14 CU CD hole H10 Shaft d9 Cap bolt 25 10 to 50,75,100 84.5 126.5 116.5 10 5 14 30 10 to 50,75,100 104 148 138 10 6 14 40 10 to 50,75,100 104 158 144 14 7 20 Bore size (mm) CX
20 15 15 10 10 5 5 0 0 5 10 15 20 25 30 35 5 10 15 20 25 30 35 Circulating fluid temperature [] Circulating fluid temperature [] 60Hz 50Hz Fig. 8-3: Cooling Capacity 8.5 Pump Capacity 0.6 60 Usable flow rate range 0.5 50 Circulating fluid outlet (60Hz) Lifting head [m] Pressure [MPa] 0.4 40 0.3 30 0.2 20 Circulating fluid outlet (50Hz) 0.1 10 Circulating fluid return 0.0 0 0 10 20 30 40
26.4 52 8.5 40.5 40.5 27.5 21.5 21 12.5 22 11 6.5 16 5.5 53 20 49 2 8 70 70 54 7 10 CY1S32-Z M8 x 1.25 M8 x 1.25 12.5 14 33.6 64 9.5 50 50 33 26 24 11.5 23.5 8.6 20 2 5.5 9 64 26 85 52 86 66 9 12 CY1S40-Z M8 x 1.25 M8 x 1.25 12.5 41.6 74 10.5 55.5 55.5 38 27 27 10.5 22.5 14 8.6 25 5.5 74 28 51 2 10 104 76 95 9 12 Bumper bolt Adjustment bolt P Shock absorber T PB S Z PA PW Q QW R R1 UU W