Function: 2 (2 Position Double), Body Option: 20 (Body Ported/Individual Pilot EXH), Pilot: Internal Pilot, Voltage: 5 (24VDC), Lead Wire: G (Grommet Lead Wire 0.3m), Surge Suppressor: None, Manual Override: Non-locking Push Style (Flush), Piping: Side, Port Size: 02 (Base Mounted w/Sub-plate 1/4, Body Ported 1/4), Thread: F (G)
Function: 2 (2 Position Double), Body Style: 20 (Body Ported/Individual Pilot EXH), Body Option: Body Ported Type, Pilot: Internal Pilot, Voltage: 5 (24VDC), Lead Wire: G (Grommet Lead Wire 0.3m), Surge Suppressor: None, Manual Override: Non-locking Push Style (Flush), Piping: Side, Port Size: 02 (Sub-plate Plug-in 1/4, Non Plug-in 1/4, Direct Ported P,A,B Ports 1), Thread: F (G)
Type of Actuation: 1 (2 Position Single), Manifold Type: 20 (Body Ported), Pilot: Internal Pilot, Specifications: Standard, Voltage: 5 (24VDC), Electrical Entry: G (Grommet Lead Wire 0.3m), Lead Wire Length: None, Surge Suppressor: None, Manual Override: Non-locking Push Style, Port Size: 02 (Body Ported 1/4, Base Mounted Sub-plate 1/4), Thread: F (G)
Function: 1 (2 Position Single), Body Style: 30 (Body Ported/Common Pilot EXH), Body Option: Body Ported Type, Pilot: Internal Pilot, Voltage: 5 (24VDC), Lead Wire: G (Grommet Lead Wire 0.3m), Surge Suppressor: None, Manual Override: Non-locking Push Style (Flush), Piping: Side, Port Size: 02 (Sub-plate Plug-in 1/4, Non Plug-in 1/4, Direct Ported P,A,B Ports 1), Thread: F (G)
Function: 1 (2 Position Single), Body Style: 20 (Body Ported/Individual Pilot EXH), Body Option: Body Ported Type, Pilot: Internal Pilot, Voltage: 5 (24VDC), Lead Wire: G (Grommet Lead Wire 0.3m), Surge Suppressor: None, Manual Override: Non-locking Push Style (Flush), Piping: Side, Port Size: 02 (Sub-plate Plug-in 1/4, Non Plug-in 1/4, Direct Ported P,A,B Ports 1), Thread: F (G)
Function: 2 (2 Position Double), Body Style: 30 (Body Ported/Common Pilot EXH), Body Option: Body Ported Type, Pilot: Internal Pilot, Voltage: 5 (24VDC), Lead Wire: G (Grommet Lead Wire 0.3m), Surge Suppressor: None, Manual Override: Non-locking Push Style (Flush), Piping: Side, Port Size: 02 (Sub-plate Plug-in 1/4, Non Plug-in 1/4, Direct Ported P,A,B Ports 1), Thread: F (G)
Function: 2 Position Single, Body Option: Body Ported/Common Pilot EXH, Pilot: Internal Pilot, Voltage: 24VDC, Lead Wire: Grommet Lead Wire 0.3m, Surge Suppressor: None, Manual Override: Non-locking Push Style (Flush), Piping: Side, Port Size: Base Mounted w/Sub-plate 1/4, Body Ported 1/4, Thread: G, Option: -
Function: 2 Position Double, Body Option: Body Ported/Individual Pilot EXH, Pilot: Internal Pilot, Voltage: 24VDC, Lead Wire: Grommet Lead Wire 0.3m, Surge Suppressor: None, Manual Override: Non-locking Push Style (Flush), Piping: Side, Port Size: Base Mounted w/Sub-plate 1/4, Body Ported 1/4, Thread: G, Option: -
Function: 2 Position Single, Body Option: Body Ported/Individual Pilot EXH, Pilot: Internal Pilot, Voltage: 24VDC, Lead Wire: Grommet Lead Wire 0.3m, Surge Suppressor: None, Manual Override: Non-locking Push Style (Flush), Piping: Side, Port Size: Sub-plate Plug-in Terminal 1/4, Non Plug-in Std 1/4, Option: -
Type of Actuation: 2 Position Single, Manifold Type: Body Ported, Pilot: Internal Pilot, Specifications: Standard, Voltage: 24VDC, Electrical Entry: Grommet Lead Wire 0.3m, Lead Wire Length: None, Surge Suppressor: None, Manual Override: Non-locking Push Style, Port Size: Body Ported 1/4, Base Mounted Sub-plate 1/4, Thread: G, Option: -
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
This is a legacy product, and replaced byVK334-5G VK300 SOL VALVE 3-PORT. VALVE, SOL, BASE MOUNTED. VALVE. VK300. .22046 lb. 2D.
For the microspeed cylinder with clean room specifications, use GR-X-005 (5g pack). Cushion Caution 1. Readjust cushion using the cushion needle. REA Cushions are adjusted at the time of shipment. However, the cushion needle on the cover should be readjusted when the product is put into service, based on factors such as the size of the load and the operating speed.
Grease pack GR-X-005 (5g) Caution 1. Be careful of the snap ring to pop out. When replacing the rod seal, take care that the snap ring does not spring out while you are removing it. 175 Actuator / Common Precautions 1 Be sure to read before handling. Refer to the main text for precautions for each series. Precaution on designing Selection Warning Warning 1.
Example 1) In the case of PVT317-001GB-05 Example 2) In the case of PVT317-5G Note 4) In the case of CE-compliant products (-Q), coils are not shipped together. VV061 VV100 Caution When the rated voltage is AC and if it is assembled with the coil for DC, response may be delayed and occur malfunction. Also, for DC valves, when the coil for AC is assembled, it occurs malfunction.