Function: 1 (2 Position Single), Piping: 2 (Body Ported), Exhaust: 0 (Individual), Pressure Specification: Standard (0.7MPa), Coil Specification: Standard, Voltage: 6 (12VDC), Lead Wire: D (DIN Terminal w/Connector), Light/Surge Suppressor: Without light/surge voltage suppressor, Manual Override: Non-locking Push Type, Port Size: 02 (1/4), Thread: N (NPT)
Function: 2 (2 Position Double), Piping: 2 (Body Ported), Exhaust: 0 (Individual), Pressure Specification: K (High-pressure, 1MPa), Coil Specification: Standard, Voltage: 6 (12VDC), Lead Wire: D (DIN Terminal w/Connector), Light/Surge Suppressor: Without light/surge voltage suppressor, Manual Override: Non-locking Push Type, Port Size: 03 (3/8), Thread: T (NPTF)
Body Type: T (Body Ported), Valve Option: Standard Type, Pressure Specifications: Standard Type (0.7MPa), Rated Voltage: 6 (12 VDC, Semi-Standard), Electrical Entry: D (with Connector), Light_Surge Voltage Suppressor: None, Port Size: 01 [1/8 (6A)]
Body Type: T (Body Ported), Valve Option: V (Vacuum Specification Type, Semi-Standard), Pressure Specifications: Standard Type (0.7MPa), Rated Voltage: 6 (12 VDC, Semi-Standard), Electrical Entry: D (with Connector), Light_Surge Voltage Suppressor: None, Port Size: 01 [1/8 (6A)]
Body Type: T (Body Ported), Valve Option: Standard Type, Pressure Specifications: K (High-Pressure Type (1MPa), Semi-Standard), Rated Voltage: 6 (12 VDC, Semi-Standard), Electrical Entry: D (with Connector), Light_Surge Voltage Suppressor: None, Port Size: 02 [1/4 (8A)], Thread Type: N (NPT)
Body Type: T (Body Ported), Valve Option: V (Vacuum Specification Type, Semi-Standard), Pressure Specifications: Standard Type (0.7MPa), Rated Voltage: 6 (12 VDC, Semi-Standard), Electrical Entry: D (with Connector), Light_Surge Voltage Suppressor: None, Port Size: 01 [1/8 (6A)], Thread Type: N (NPT)
Body Type: T (Body Ported), Valve Option: E (Continuous Duty Type, Semi Standard), Pressure Specifications: K (High-Pressure Type (1MPa), Semi-Standard), Rated Voltage: 6 (12 VDC, Semi-Standard), Electrical Entry: D (with Connector), Light_Surge Voltage Suppressor: None, Port Size: 02 [1/4 (8A)]
Body Type: T (Body Ported), Valve Option: Standard Type, Pressure Specifications: Standard Type (0.7MPa), Rated Voltage: 6 (12 VDC, Semi-Standard), Electrical Entry: D (with Connector), Light_Surge Voltage Suppressor: None, Port Size: 02 [1/4 (8A)], Thread Type: F (G)
Body Type: T (Body Ported), Valve Option: V (Vacuum Specification Type, Semi-Standard), Pressure Specifications: Standard Type (0.7MPa), Rated Voltage: 6 (12 VDC, Semi-Standard), Electrical Entry: D (with Connector), Light_Surge Voltage Suppressor: None, Port Size: 02 [1/4 (8A)], Thread Type: N (NPT)
Body Type: T (Body Ported), Valve Option: Y (Energy-Saving Type, Semi-Standard), Pressure Specifications: Standard Type (0.7MPa), Rated Voltage: 6 (12 VDC, Semi-Standard), Electrical Entry: D (with Connector), Light_Surge Voltage Suppressor: None, Port Size: 02 [1/4 (8A)], Thread Type: F (G)
Body Type: T (Body Ported), Valve Option: Standard Type, Pressure Specifications: Standard Type (0.7MPa), Rated Voltage: 6 (12 VDC, Semi-Standard), Electrical Entry: D (with Connector), Light_Surge Voltage Suppressor: None, Port Size: 01 [1/8 (6A)], Thread Type: N (NPT)
Body Type: T (Body Ported), Valve Option: Standard Type, Pressure Specifications: Standard Type (0.7MPa), Rated Voltage: 6 (12 VDC, Semi-Standard), Electrical Entry: D (with Connector), Light_Surge Voltage Suppressor: None, Port Size: 01 [1/8 (6A)], Thread Type: T (NPTF)
Body Type: T (Body Ported), Valve Option: Standard Type, Pressure Specifications: Standard Type (0.7MPa), Rated Voltage: 6 (12 VDC, Semi-Standard), Electrical Entry: D (with Connector), Light_Surge Voltage Suppressor: None, Port Size: 02 [1/4 (8A)]
Body Type: T (Body Ported), Valve Option: Standard Type, Pressure Specifications: Standard Type (0.7MPa), Rated Voltage: 6 (12 VDC, Semi-Standard), Electrical Entry: D (with Connector), Light_Surge Voltage Suppressor: None, Port Size: 02 [1/4 (8A)], Thread Type: N (NPT)
Body Type: T (Body Ported), Valve Option: E (Continuous Duty Type, Semi Standard), Pressure Specifications: K (High-Pressure Type (1MPa), Semi-Standard), Rated Voltage: 6 (12 VDC, Semi-Standard), Electrical Entry: D (with Connector), Light_Surge Voltage Suppressor: None, Port Size: 02 [1/4 (8A)], Thread Type: N (NPT)
Model: 23, Orifice Size: 2 (3mm), Configuration: 0 (N.C./Single Unit), Solenoid Valve Option: V (Brass Body, FKM Seal, Class B, for Non-Lube Treatment), Suffix: Standard, Port Size: 02 (1/4), Thread Type: N (NPT), Voltage: 6 (12VDC), Electrical Entry: D (DIN Connector), Full-wave Rectifier: None
Model: 21, Orifice Size: 1 (2mm), Configuration: 0 (N.C./Single Unit), Solenoid Valve Option: Brass Body, NBR Seal, Class B, Suffix: Standard, Port Size: 01 (1/8), Thread Type: Rc, Voltage: 6 (12VDC), Electrical Entry: D (DIN Connector), Full-wave Rectifier: None
Model: 21, Orifice Size: 1 (2mm), Configuration: 2 (N.O./Single Unit), Solenoid Valve Option: A (Brass Body, FKM Seal, Class B), Suffix: Standard, Port Size: 02 (1/4), Thread Type: N (NPT), Voltage: 6 (12VDC), Electrical Entry: D (DIN Connector), Full-wave Rectifier: None
Model: 21, Orifice Diameter: 1 (2 mm), Valve/Body Configuration: 0 (N.C./Single Unit), Solenoid Valve Option: Brass Body (Aluminum for Air Type), NBR Seal, Class B, Suffix: Standard, Port Size: 02 (1/4), Thread Type: N (NPT), Voltage: 6 (12VDC), Lead Wire: D (DIN Connector)
Model: 22, Orifice Diameter: 2 (3 mm), Valve/Body Configuration: 0 (N.C./Single Unit), Solenoid Valve Option: Brass Body (Aluminum for Air Type), NBR Seal, Class B, Suffix: Standard, Port Size: 02 (1/4), Thread Type: N (NPT), Voltage: 6 (12VDC), Lead Wire: D (DIN Connector)