SMC Corporation of America
Elite Part Number Search
Search Results "VQD1151-6M-M5"

Mounting: Double Clevis, Bore Size: 32mm, Stroke: 15mm, Option: Standard (Rod End Female Thread), Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Rated Voltage: 12 VDC, Electrical Entry: M Plug Connector With Lead Wire, Surge Voltage Suppressor: -, Manual Override: -, Piping: -, Port Thread

Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 30, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~50, End Locking: No, Valves: Presence, Operating Pressure(MPa): 0.15~0.7, Support bracket: Through-hole

Function: Normally Open, Piping: Base Mounted, Body Option: Individual EXH, Specifications: Standard, Voltage: 12VDC, Lead Wire: M Plug Connector w/Lead Wire 0.3m, Surge Suppressor: None, Manual Override: Non-locking Push Style, Port Size: Base Mounted w/Sub-plate 1/8, Thread: -, Bracket: -, CE-Compliant: -, Cable length: -

Function: Normally Closed, Piping: Base Mounted, Body Option: Individual EXH, Specifications: Standard, Voltage: 12VDC, Lead Wire: M Plug Connector w/Lead Wire 0.3m, Surge Suppressor: None, Manual Override: Non-locking Push Style, Port Size: Base Mounted w/Sub-plate 1/8, Thread: -, Bracket: -, CE-Compliant: -, Cable length: -

Function: Normally Closed, Piping: Base Mounted, Body Option: Individual EXH, Specifications: Standard, Voltage: 12VDC, Lead Wire: M Plug Connector w/Lead Wire 0.3m, Surge Suppressor: None, Manual Override: Non-locking Push Style, Port Size: Base Mounted w/Sub-plate 1/8, Thread: NPT, Bracket: -, CE-Compliant: -, Cable length: -

Function: 2 Position Single, Piping: Body Ported, Exhaust: Individual, Specifications: Standard, Voltage: 12VDC, Lead Wire: M Plug Connector w/Lead Wire 0.3m, Surge Suppressor: None, Manual Override: Non-locking Push Style, Port Size: Base Mounted w/Sub-plate 1/8, Body Ported 1/8, Thread: NPT, Option: -, CE Compliant: -

Type: Solenoid Valves, Application: Single Unit, Mounting Orientation: Direct, Voltage: DC12V, Specification: Standard, Valve Type: 5-Port Valve, Actuation: [Single] Single, Status at Power Off: Self-Recovery (Pressure Differential Return), Valve Positions: 2-Position Exhaust, Pipe Port Type: M, Port Size: M3, Pressure Rating(MPa): 0.15 to 0.7, Driving Type: Pilot Type Spool, Pilot Air Supply

Type: Solenoid Valves, Application: Single Unit, Mounting Orientation: Direct, Voltage: DC12V, Specification: Standard, Valve Type: 5-Port Valve, Actuation: Double, Status at Power Off: Self-Retaining, Valve Positions: 2-Position Exhaust, Pipe Port Type: M, Port Size: M3, Pressure Rating(MPa): 0.1 to 0.7, Driving Type: Pilot Type Spool, Pilot Air Supply: Internal, Seal Type: Soft Seal, Manual

Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 10, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Plate Cylinder, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~50, End Locking: No, Valves: Presence, Operating Pressure(MPa): 0.15~0.7, Port thread type: -, Auto

Bore Size: 32mm, Stroke: 10mm, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Rated Voltage: 6 (12VDC), Electrical Entry: M [M-type plug connector w/lead wire (300mm)]

Mounting: D (Double Clevis), Bore Size: 32mm, Stroke: 15mm, Option: Standard (Rod End Female Thread), Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Rated Voltage: 6 (12 VDC), Electrical Entry: M (M Plug Connector With Lead Wire)

Mounting: B (Through Hole), Bore Size: 32mm, Stroke: 30mm, Option: Standard (Rod End Female Thread), Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Rated Voltage: 6 (12 VDC), Electrical Entry: M (M Plug Connector With Lead Wire)

Function: 2 (2 Position Double), Piping: 2 (Body Ported), Exhaust: 0 (Individual), Specifications: Standard, Voltage: 6 (12VDC), Lead Wire: M (M Plug Connector w/Lead Wire 0.3m), Surge Suppressor: None, Manual Override: Non-locking Push Type, Port Size: M3 (Body Ported M3X0.5)

Function: 1 (2 Position Single), Piping: 2 (Body Ported), Exhaust: 0 (Individual), Specifications: Standard, Voltage: 6 (12VDC), Lead Wire: M (M Plug Connector w/Lead Wire 0.3m), Surge Suppressor: None, Manual Override: Non-locking Push Type, Port Size: M3 (Body Ported M3X0.5)

Type of Actuation: 1 (2 Position Single), Manifold Type: 20 (Body Ported), Pilot: Internal Pilot, Specifications: Standard, Voltage: 6 (12VDC), Electrical Entry: M (M Plug Connector w/Lead Wire 0.3m), Lead Wire Length: None, Surge Suppressor: None, Manual Override: Non-locking Push Style, Port Size: 02 (Body Ported 1/4, Base Mounted Sub-plate 1/4), Thread: T (NPTF)

Type of Actuation: 1 (2 Position Single), Manifold Type: 40 (Base Mounted), Pilot: Internal Pilot, Specifications: Standard, Voltage: 6 (12VDC), Electrical Entry: M (M Plug Connector w/Lead Wire 0.3m), Lead Wire Length: None, Surge Suppressor: None, Manual Override: Non-locking Push Style, Port Size: 02 (Body Ported 1/4, Base Mounted Sub-plate 1/4), Thread: N (NPT)

Function: A (4 Position Dual 3 Port N.C./N.C.), Pilot: Internal Pilot, Back Pressure Check: None, Voltage: 6 (12VDC), Common: +COM, Lead Wire: M (M Plug Connector w/Lead Wire 0.3m), Surge Suppressor: None, Switch: None, Manual Override: Non-locking Push Style, Port Size: C6 (ø6 One-touch Fitting)

This is a legacy product. Please contact us for the latest version.sales@ocaire.com

This is a legacy product. Please contact us for the latest version.sales@ocaire.com

Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 30, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~50, End Locking: No, Valves: Presence, Operating Pressure(MPa): 0.15~0.7, Support bracket: Through-hole