Bore size NTJ-010A NTJ-006A 8 6 M3 x 0.5 2.4 5.5 6.4 5.5 6.5 M3 x 0.5 6 12.5 M4 x 0.7 3.2 7 8.1 7 8.5 M4 x 0.7 8 14.5 NTJ-015A 10 M5 x 0.8 4 8 9.2 10.5 M5 x 0.8 16.5 10 9 (mm) Standard C D E F B A J K L M N O P G H I Bore size 8 6 M2.5 x 0.45 13 7 7 10 9 19 3 5 4 9 3.5 8 7 5.3 24 M3 x 0.5 13 7 8 11 10 21 3 6 5 11 4.5 10 8 5.3 25 10 13.5 M3 x 0.5 7 8.5 11.5 10.5 22 3.2 6 6 12 5 11 8.5 5.6
HAA HAW Bracket 2 x M5, Rc 1/4, NPT 1/4 AT IDF IDU 24 40 50 IN IDF FS 2 x 4.5 66 IDFA IDFB Model Connection Rc 1/4 NPT 1/4 M5 SFB100-02, 200-02 SFB101-02, 201-02 SFB104-M5 IDH ID IDG SFB102-02, SFB202-02: TSJ 1/4 (Tube Swage Joint) IDK 2 x 4.5 Bracket AMG 2 x TSJ 1/4 Width across flats AFF 24 40 50 AM IN AMD 87 AMH AME SFB103-02, SFB203-02: UOJ 1/4 (Union O-ring Joint) AMF 2 x 4.5 Bracket
HRZ x V x C x iT it m x C x (T0 Tt) it Q = = HRZD 1 x 300 x 4.186 x 103 x 12 900 = = 16744 [J/s] 16.7 [kW] m x C x (T0 Tt) it x 860 x V x 60 x C x iT it x 860 HRW Q = = Cooling capacity = Considering a safety factor of 20%, 16.7 [kW] x 1.2 = HECR 1 x 300 x 60 x 1.0 x 103 x 12 15 x 860 20 [kW] = HEC Thermo-chiller Q x t: Heat capacity [kJ] 16744 [W] = 16.7 [kW] Water bath 20C HEB Cooling
X 0.8 X 6 3-M5 X 0.8 X 6 AL800-12 to 14-1 AL900-20-1 11/4 / 11/2 2 ( ) With float switch 1.17-10 Auto Feed Lube ALF400 to 900 Standard Specifications Auto Feed Lube Auto Feed Tank Model 1 2 ALT-9-IS1 2 ALF400 ALF400-06 ALF500 ALF600 ALF800 ALF900 ALT-5 ALT-5-ISALT-9 ALT-9-IS2 1 1 1 1 2 4 1 4 3 AIR: OIL: 4 1 4 3 2 1 4 1 Port size 8 3 8 3 1 Fluid Proof pressure Max. operating pressure Air
Table 3.3-1 Power supply cable and earth leakage breaker (Recommended) Earth leakage breaker Terminal Power Recommended Cable Sensitivity block Model supply crimp Specifications Breaker of screw voltage terminal 1 size leakage diameter (A) current (mA) 4 cores x AWG10 HRL100-A-20 3-phase (4 cores x 5.5 mm2) R5.5-5 30 200V AC including (50Hz) ground M5 30 4 cores x 3-phase HRL200-A-20 40 AWG8
) M5 30 3-phase 4 cores x 460 to 480V AWG8 AC(60Hz) (4 cores x 8 mm2) HRL300-A-40 R8-5 40 including ground 1 Cable specifications are the examples when using the product at a continuous allowable operating temperature of 70 oC, with an operating voltage of 600 V and two kinds of plastic insulated wires at an ambient temperature of 30 oC.
x V x C x iT it m x C x (T0 Tt) it Q = = 1 x 150 x 4.186 x 103 x 10 900 = = 6977 [J/s] 7.0 [kW] m x C x (T0 Tt) it x 860 x V x 60 x C x iT it x 860 Q = = Cooling capacity = Considering a safety factor of 20%, 7.0 [kW] x 1.2 = 1 x 150 x 60 x 1.0 x 103 x 10 15 x 860 8.4 [kW] = Q x t: Heat capacity [kJ] Thermo-chiller Water bath 6977 [W] = 7.0 [kW] 20C Cooling capacity = Considering a safety
P P 1 to 10 PFA30m P P P 5 to 50 P P P 10 to 100 31m P P P 20 to 200 P P P 50 to 500 P P P P 150 to 3000 P P P P 300 to 6000 P P P P 6000 to 12000 Series variations For Water Flow rate Remote type Output specification Port size (Rc, NPT, G) Integrated measurement display type Display unit Sensor unit Switch output 3/8 1/2 3/4 range l/min PFW31m 30m 32m PFW704 720 740 PFW504 520 540 P P
Operating pressure (MPa) U: Maximum speed (mm/s) Stroke (mm) Mode of operation Inclined operation Vertical operation Horizontal operation Review of load weight and operating pressure Lo Fn W Guide First tentative bore size determination F3 D1.6 x P First tentative bore size determination F2 D1.6 x P First tentative bore size determination F1 D1.6 x P WB Inclined operation W+WBWV PPV
A : Max. 3.5 AR20-A to AR25-A : Max. 4 AR30-A to AR40-06-A : Max. 8 Model Standard specifications Optional specifications Round type pressure Round type pressure gauge gauge (with color zone) Bracket mount Panel mount P1 P2 A B C D F J H J H J M N Q R S T U V W Y Z AR10-A M5 x 0.8 1/16 25 47.4 11 12.5 M18 x 1 12.5 26 26 25 28 30 4.5 6.5 40 2 18 18.5 AR20-A 1/8, 1/4 1/8 40 67.4 23.5 22
2] 2) 100 [m/s CE / UKCA (EMC RoHS ) 1) 10~150Hz X,Y,Z 2 () 2) X,Y,Z 3 () ZQ05A ZQ07A ZQ10A [mm] 0.5 0.7 1.0 [MPa] 0.35 0.43 1) -80 [kPa] 1) 5 10 22 [L/min (ANR) ] 1) 15 25 47 [L/min (ANR) ] (P) 0.3 to 0.5 2) 0 to 0.45 3) [MPa] (PD) [MPa] 0.75 8 6 4 65 68 70 4) () 64 66 68 [dB (A)] 1) 2) P 0.05MPa 3) 0.1MPa 4) ZQ000A 3/ (sbar) ] 0.31 C[dm VPV B 0.23 () Cv 0.09 3/ (sbar) ] 0.24
Real-time switch output Hysteresis mode ON Flow rate conversion YES OFF P-1 P-2 Normal condition {0C, 101.3 kPa, Dry air} or standard condition (ANR) {20C, 101.3 kPa, 65% RH} can be selected.
Supply pressure (MPa) Flow rate (l/min (ANR)) 13-4-27 8 Series ZMA Dimensions 111 S: Vacuum pressure switch trimmer Pilot valve for vacuum pressure T: Release period adjustment trimmer Pilot valve for vacuum release M5 x 0.8 through (P, E port) Release flow adjustment screw 3-Rc 1/8 SUP.
I"P.1/4, .. . , ASP530F-N03-11 S 3/S' ~ 25.9 1 51Jtr 11 / 16" 28.6 ~6~5 ~ 61 ;a.: ~:B-.9 :2D.S 220 tU6' /36,3 . 34:7 .26~ 21.7 . . ~ A efertlllCe dll'l'lerlSlons 1 01 NPT Ihmads aller installalion 3 Speed Controller 5 . ASP w"" P;lo' Ch.,k V,'v. efles Construction Parts list .QesCr;plian ' ''' fi1t~lal , . . .
) M14 x 1.5 RB1412(C) RB2015(C) M20 x 1.5 M27 x 1.5 RB2725(C) RBL1006(C) RBL series Coolant resistant type Basic type M10 x 1.0 RBL1007(C) RBL1411(C) P.906 to 0.05 to 5 M14 x 1.5 RBL1412(C) RBL2015(C) M20 x 1.5 M27 x 1.5 M16 x 1.5 M20 x 1.5 M25 x 1.5 M30 x 1.5 M32 x 1.5 RBL2725(C) Foot bracket (Except RBQ) RBQ1604(C) RBQ series Short type Basic type RBQ2007(C) Load RBQ2508(C) P.910 to 0.05
0.7 Female mounting threads Thread depth 6 Silencer (AN120-M5) Option (PB1011 built-in solenoid valve type only) AIR SUP (pilot air supply port) 1/8 FLUID IN 1/8 9 11 22 13 SUP IN 11 18.5 32 EXH Foot bracket Option 45 AIR EXH (pilot air exhaust port) 2-M4 x 0.7 Female mounting threads Thread depth 6 M5 x 0.8 Thread depth 10 The PB1013 air operated type has a plug. 20 Series PA3000/5000
Then, the charge time (T) for a 10 L tank: T = t x = 3.2 x = 32 (s). V 10 T = t x = 89 x = 89 (s).
Stroke + 126 3.3 24 1 5 3 5.8 8 3 21 59 F 5H9 +0.030 0 depth 5 T-slot dimensions (2/1) 29.5 5H9 +0.030 0 depth 5 6 T-slot 4-M5 x 0.8 (for body mounting) thread depth 8 (11.5) 38 E Refer to page 299 for mounting.
(de-energized) 490 m/s2 in X, Y, Z directions 3 times each 1000 Vp-p, Pulse width 1 s, Rise time 1 ns Status LEDs Response time Hysteresis Power supply voltage Enclosure Operating temperature range Withstand voltage Insulation resistance Vibration resistance Impact resistance Noise resistance Note 1) For digital flow switch with unit switching function.
-04 AS121F-M5-03 5/32" M5 x 0.8 M5 x 0.8 8 17.3 22.2 7 9.3 22.1 9.6 4 25 25.8 22.1 28.6 9.3 17.3 AS121F-U10/32-04 AS121F-U10/32-03 5/32" 10-32UNF 10-32UNF AS121F-M5-06 AS121F-M5-05 3/16" M5 x 0.8 M5 x 0.8 11.4 21.3 26.1 7 16.5 13.5 11.7 22.9 11.6 18.1 6 AS121F-U10/32-06 AS121F-U10/32-05 3/16" 10-32UNF 10-32UNF 8 11.7 28.6 25.8 22.2 25 9.6 AS221F-01-23 AS2 1F-M5-07 20.4 16 9.3 27.5 3.2 1/4