Valve model Type of actuation Port size 1 4/2 (P A/B) Flow characteristics Note 2) Note 3) Effective area mm2 4/2 5/3 (A/B EA/EB) Weight (g) Pilot port size Cv C [dm3/ (s bar)] b Cv C [dm3/ (s bar)] b Grommet Single Double Closed center Exhaust center Pressure center Single Double Closed center Exhaust center Pressure center Single Double Closed center Exhaust center Pressure center 48
N01 R1/8 (M5 ) NPT1/8 (M5 ) C3602() O HNBR 45 g 46 g -62No.PS-OMM0006CN-E (M8(3 )71 ) 01/N01 5 4 M5/C4/C6 M5 5 -63No.PS-OMM0006CN-E W1/WF1 4 ( ISO228-1) -64No.PS-OMM0006CN-E A 01/N01 W1/WF1 -65No.PS-OMM0006CN-E B W1/WF1 -66No.PS-OMM0006CN-E D 01/N01 W1/WF1 -67No.PS-OMM0006CN-E 01/N01 W1/WF1/M5/C4/C6 -68No.PS-OMM0006CN-E + 01/N01 W1/WF1/M5/C4/C6 -69No.PS-OMM0006CN-E
VPA 0.4 0.3 VPA3 0.2 0.1 0.2 0.3 0.4 0.5 0.6 Operating pressure range MPa Flow Rate Characteristics/Weight Type of actuation Valve model Port size 14/2 (PA/B) Flow rate characteristics Note 2) Effective area mm2 4/25/3 (A/BEA/EB) Note 3) Pilot port size Weight (g) Cv C [dm3/ (s bar)] b Cv C [dm3/ (s bar)] b Single Double Closed center Exhaust center Pressure center Single Double Closed center
Time Repeatability 0.2% F .S. 1 digit or less IP65 compatible Dusttight/Splash proof type 16-2-16 3 Series ZSE40/ISE40 High Precision, Digital Pressure Switch How to Order 0.100 to 1.000 MPa For positive pressure Set pressure range Nil ISE40 01 22 For positive pressure ZSE ISE ZSE40 01 22 For vacuum/compound pressure PSE Z I SE3 PS Option Set pressure range Nil F Nil For vacuum pressure
SYJA524-01 SYJA712-01 SYJA722-01 SYJA714-01 SYJA714-02 0.76 0.69 0.69 0.66 0.63 0.64 0.51 0.42 0.34 0.33 0.45 0.48 2.5 2.4 2.7 2.6 2.3 2.3 0.77 0.72 0.71 0.74 0.70 0.68 0.43 0.38 0.32 0.31 0.21 0.31 2.8 2.7 2.9 3.0 2.8 2.7 N.C. N.O. Rc 1/8 Body ported 80 Rc 1/8 Rc 1/4 Rc 1/8 Rc 1/4 M5 x 0.8 130 (Without subplate 80) N.C. Base mounted (with sub-plate) SYJA724-01 SYJA724-02 N.O.
Caution REC25 101110-AS2001F-06-X214 10-AS2301F-01-06-X214 10-AS2201F-01-06-X214 REC32 101110-AS3001F-08-X214 10-AS2301F-01-06-X214 10-AS2201F-01-06-X214 REC40 101110-AS3001F-08-X214 10-AS3301F-02-08-X214 10-AS3201F-02-08-X214 2. Speed control is possible with meter-in and meter-out types of speed controllers.
-01-D Meter-out M5 type U10/32 port AS3200-02-D Meter-out M5 type U10/32 port AS2210-01-D AS3210-02-D Component Parts No.
ASD230F-M5-04D-X12 744 ASDF-D Series Dual Speed Controller Adjustable by Flat Head Screwdriver with One-touch Fitting How to Order ASD 3 3 0 F 01 06 S D Made to Order Lubricant: Vaseline X12 AS-F Ex.)
(N specifications) AS4200-04 How to Order 01 S AS 2 2 0 0 AS3200-03 Body size AS2200-02 1 2 3 4 M3, M5 standard AS2200-01 AS1200-M5 Made to Order Refer to page 647 for details. 1 8 1 4 , standard standard standard 8 3 2 1 Lock nut option Type J Hexagon lock nut Round lock nut Nil AS1200-M3 Direct cylinder elbow type 2 Option AS1400-M3 Direct cylinder flat elbow type 4 Nil None With seal S
used STX ETX ACK NAK ASCII code 30H 31H 32H 33H 34H 35H 36H 37H 38H 39H Number used 0 1 2 3 4 5 6 7 8 9 ASCII code 2DH 20H Number used SP Space Minus ASCII code 41H 42H 43H 44H 45H 46H 47H 48H 49H 4AH Character used A B C D E F G H I J ASCII code 4BH 4CH 4DH 4EH 4FH 50H 51H 52H 53H 54H Character used K L M N O P Q R S T ASCII code 55H 56H 57H 58H 59H 5AH Character used U V W X Y Z HEF002
58H 59H 5AH Character used U V W X Y Z INR-244-831 3-9 Troubleshooting 4 Troubleshooting The table below shows the solutions for the problems.
Refer to dimensions on pages 14-20-40 to 14-20-41 for details. w e Sight glass Tempered glass AM850 is aluminum casted. Replacement Parts AME450 Model No.
M Dimensions with mounting bracket Model Port size (Nominal size B) A B C D E F G S 6.0 , 2 H 463.5 I 180 J 30 K 15 L 24 N 120 O 184 P 220 Q 110 R 18 460.5 AMG850 1 2 13 42 348 220 57.5 220 10 14-20-7
M Dimensions with mounting bracket Model Port size (Nominal size B) A B C D E F G S 6.0 , 2 1 H 463.5 I 180 J 30 K 15 L 24 N 120 O 184 P 220 Q 110 R 18 460.5 AMH850 1 2 13 42 348 220 57.5 220 10 Please refer to Made to Order Specifications of Series AMH on pages 14-20-55 to 14-20-57. 14-20-35
When an analog output unit or analog input unit is connected to Slot 0, and channel 0 needs to be changed to analog range 4-20mA. 3) Select Channel0 (Sub Index 01) from the Slot _AnalogRange (Index 300B) folder.
Control Method: S (Meter-in, Light Blue), Stud Position: A (Right Side), Tube Diameter: 07 (ø1/4"), Thread Type: N (NPT), Port Size: 01 (1/8), Sealing Method: S (w/Sealant)
Control Method: S (Meter-in, Light Blue), Stud Position: B (Left Side), Tube Diameter: 07 (ø1/4"), Thread Type: N (NPT), Port Size: 01 (1/8), Sealing Method: S (w/Sealant)
Control Method: S (Meter-in, Light Blue), Stud Position: A (Right Side), Tube Diameter: 03 (ø5/32"), Thread Type: N (NPT), Port Size: 01 (1/8), Sealing Method: S (w/Sealant)
Control Method: S (Meter-in, Light Blue), Stud Position: A (Right Side), Tube Diameter: 04 (ø4), Thread Type: R, Port Size: 01 (1/8), Sealing Method: S (w/Sealant)
Control Method: S (Meter-in, Light Blue), Stud Position: A (Right Side), Tube Diameter: 06 (ø6), Thread Type: R, Port Size: 01 (1/8), Sealing Method: S (w/Sealant)