SMC Corporation of America
Elite Part Number Search
Search Results "PFM511-N02-2-R"

Remove the hexagon socket head cap screws (11). 2. Hold either body A (1) or body B (2), and separate the body A and B by pushing the vane shaft (3) out. 3. Take out the vane shaft (3), stoppers (4) and (5). 1. Mount the vane shaft (3) into the body B (2). 2. Mount the stopper seals (7) into the stopper (4). 3. Mount the stoppers (4) and (5) into the body B (2).

9 e r t q !3 w !0 @3 @2 !1 !2 !5 !4 y u i o @1 @0 !8 !6 Component Parts Component Parts Qty. No. Description Material Note No.

9 e r t q !3 w !0 @3 @2 !1 !2 !5 !4 y u i o @1 @0 !8 !6 Component Parts Component Parts Qty. No. Description Material Note No.

(Removal procedure and ) -51No.EX-OMI0032-G Wiring Internal circuit and wiring EX510-DXB1: Input unit for 2-wire type (1 connector 2-input type) EX510-DXN1: Input unit for NPN (1 connector 2-input type) EX510-DXP1: Input unit for PNP (1 connector 2-input type) -52No.EX-OMI0032-G EX510-DXN2: Input unit for NPN (1 connector 1 input type) EX510-DXP2: Input unit for PNP (1 connector 1 input type

Flow Characteristics/Weight 1 4/2 (P A/B) 4/2 5/3 (A/B EA/EB) Flow characteristics Weight (kg) Port size Model Type of actuation C [dm3/(sbar)] b Cv C [dm3/(sbar)] b Cv 3 8 1 2 3 4 3 8 1 2 3 4 3 8 1 2 3 4 3 8 1 2 3 4 4.5 5.1 5.6 4.5 5.1 5.6 4.0 4.5 5.0 4.2 (4.0) 4.8 (4.5) 5.5 (4.8) 0.33 0.28 0.28 0.33 0.28 0.28 0.29 0.23 0.23 0.29 (0.28) 0.24 (0.27) 0.23 (0.30) 16 19 21 16 19 21 15 18

Combinations Converter nominal size Control valve Valve unit size Combined valve 2 0, 1, 2, 3 0, 1, 2, 3 0, 1, 2, 3 2 0, 1, 2, 3 0, 1, 2, 3 0, 1, 2, 3 2 0, 1, 2, 3 0, 1, 2, 3 2 0, 1, 2, 3 0, 1, 2, 3 0 1 2 3 0 1 2 3 0 1 2 0 1 2 S 63 Speed controller Combined valve (Stop valve, Skip valve) The stop valve for intermediate stopping and the skip valve for last-forwarding are compound integrated

If mixed, normal transmission of data cannot be assured. 2. Connect the shield line of CC-Link dedicated cable to "SLD" of each unit. -16No.EX-OMI0001-I 2. Power supply wiring Connect power supply wiring to the two power supply 2-pin connectors. Power supply consists of 2 systems, but they it can be used with both of single power supply and separate power supplies.

Description Material 1 Body Aluminum die-cast 2 Flange Aluminum die-cast 3 Bowl Stainless steel e r Replacement Parts No.

Memory map of input data Data (2 byte) Input area Branch connector (INPUT) MSB LSB MSB LSB 15 8 7 0 byte (b+1) byte (b) Word (a) COM A byte (b+3) byte (b+2) Word (a+1) COM B byte (b+5) byte (b+4) Word (a+2) COM C byte (b+7) byte (b+6) Word (a+3) COM D (a, b=0 to) Memory map of output data Data (2 byte) Output area Branch connector (OUTPUT) MSB LSB MSB LSB 15 8 7 0 byte (d+1) byte (b) Word

Contents 1 1 200 to 220 VAC 100 to 240 VAC 2 2 200 to 220 VAC 100 to 240 VAC PE 2 1 3 3 PE HRG HRS HRZ HRZD HRW HEC HEB HED Technical Data Related Products 2. Communication connector (RS-232C or RS-485) D-sub 9 pin (socket) Holding screw: M2.6 Signal contents 3 2 Pin No. RS-232C RS-485 5 4 1 1 Unused BUS+ 2 RD BUS 3 SD Unused 4 Unused Unused 5 SG SG 6-9 Unused Unused 9 8 7 6 3.

1.0 to 38.0 2 to 76 8 to 186 CFM x 10-2 CFM x 10-2 CFM x 10-1 CFM x 10-1 CFM x 10-1 flow Flow Min. setting/display unit 0.5 2.0 0.5 1.0 2.0 CFM x 10-2 CFM x 10-2 CFM x 10-1 CFM x 10-1 CFM x 10-1 Accumulated Setting/display flow range 0 to 9 ft3 x 10-2 0 to 9 ft3 x 10-1 flow Min. setting/display unit 1 ft3 x 10-3 1 ft3 x 10-1 Conversion of accumulated pulse 0.5 2.0 0.5 1.0 2.0 ft3 x 10-2/

Nominal thread size Required torque Port size Width across flats of attachment Rc1NPT1 36 to 38 Nm 1 45 mm Rc1 1/2, NPT1 1/2, Rc2, NPT2 48 to 50 Nm 1 1/2 60 mm 2 70 mm 16 No.PF-OMU0002-D Wiring Connection Connections should only be made with the power supply turned off. Use a separate route for the product wiring and any power or high voltage wiring.

PVC PVC PVC PVC PVC , -10No.PF-OMM0004-D -11No.PF-OMM0004-D N M8 M8 R / ZS-40-K PF3W704/720 4 3X8 ZS-40-L PF3W740 4 3X8 ZS-40-M PF3W711 4 4X10 M8 ZS-40-A 3 m 2 250 L/min PVC 25 A ZS-40-U25 25 A PVC 1 PVC 30 A ZS-40-U30 30 A PVC 1 25 A ZS-40-U25-A 1 M5x80 2 30 A ZS-40-U30-A 1 M5x65 2 PVC 1~2% -12No.PF-OMM0004-D 1 DC+ 2 OUT2 3 DC4 OUT1 M8 IN OUT OUT1OUT2 ON UP ON/OFF SET

Problem Possible cause Investigation method Countermeasure (1)(2) Connect the (1) Check if the output current is 80 mA or more. appropriate load. (2) Check if the specified load is (3) Use a relay with a surge connected.

Product Description 1 1-1 Model 1 1-2 Specifications 1 1-3 Effective Torque 2 1-4 Key (Keyway) Position and Rotation Range 2 2. Internal Construction and Description of Individual Parts 3 2-1 Single Vane Type 3 2-2 Double Vane Type 4 3. Basic Circuit 5 3-1 Circuit Configuration 5 3-2 Preferred Components 5 4.

for NPN output Brown Brown Brown Black Blue Load Black Blue Relay Black Blue Load Switch 1 Switch 1 Switch 1 Load Relay contact Brown Black Blue Brown Black Blue Brown Black Blue Switch 2 Relay Switch 2 Switch 2 The indicator lights will light up when both switches are turned ON. 2-wire with 2 switch AND connection 2-wire with 2 switch OR connection When

Circuit (of Class 2) which is of maximum 30 Vrms (42.4 V peak) or less, with UL1310 Class 2 power supply unit or UL1585 Class 2 transformer. The product is a UL approved product only if it has a mark on the body. Use the specified voltage. Otherwise failure or malfunction can result. Insufficient supply voltage may not drive a load due to a voltage drop inside the product.