Series V V Y Series V V J Applicable cylinder size Cylinder size y Series C dm bar)] b Cv 6 8 10 12 16 20 25 32 40 50 63 80 100 0.28 0.37 0.28 0.29 0.36 0.32 0.35 0.29 0.90 1.4 2.5 0.12 0.21 0.74 V1Y V2Y V3Y V4Y 3.4 5.2 Series VY 10 0.46 0.83 2.9 V1J V2J V3J Series VJ Conditions Pressure: 0.5MPa Load rate: 50% Cylinder speed: 450mm/s

Insulation resistance Between external terminal batch and case: 2M (at 500VDC) 2hrs. each in X, Y, Z directions at smaller of 10 to 500Hz with amplitude 1.5mm, or acceleration 10G Vibration resistance 100G in X, Y, Z directions, 3 times each Impact resistance Note 1) Not available on analog output type. Refer to CAT.E824-A "Pressure Switch" for details on switches.

B Slotted locking type Nil Without valve unit Light/Surge voltage suppressor Nil None With light/surge voltage suppressor (solenoid valve connector type only) Pilot valve specifications Z DC: 1W type (with light: 1.05W) S With surge voltage suppressor Nil AC type Electrical entry DC: 0.45W type (with light: 0.5W) Y Nil Air operated For 24, 12, 6, 5, 3 VDC L Lead wire length 0.3m LN Without

Z directions for 2hrs. each (deenergized) 980m/s (100G) in X, Y, Z directions 3 times each (deenergized) In a temperature range of 0 to 50C, 2% F.S. or less of pressure measured at 25C Vibration resistance Impact resistance Temperature characteristics 01: R1/8, M5 x 0.8, T1: NPT1/8, M5 x 0.8, W1: Rc1/8 C4: With 4 One-touch fitting, C6: With 6 One-touch fitting, M5: M5 female threads 5 wire

input (solid state switch or reed switch), input 5ms or more IP65 Operating: 0 to 50C, Stored: 10 to 60C (With no condensation or freezing) Operating and stored: 35 to 85% RH (With no condensation) 250VAC for 1 min, between all lead wires and enclosure 2M or more (at 50VDC) between all lead wires and enclosure 10 to 500Hz with 1.5mm amplitude or 98m/s2, whichever is smaller 980m/s2 in X, Y,

Y 3 X 3 ZZY 45 J 1 U Note 1) With ejector Enter the following together with the manifold number: 1. Part No. of solenoid for SY3000/SX3000 2.

Different units (mm, inch, degree, and PLS) are applicable to different systems: mminch X-Y table, conveyor (Select mm or inch depending on the machine specifications) degree Rotating body (360 degrees/rotation) PLS X-Y table, conveyor When you change the unit, note that the values of other parameters and data will not be changed automatically.

And then, select the "Uninstall". 3) Click "Yes (Y)". 4) When uninstallation of the controller setting software is completed, the uninstallation program will end automatically. 4.2 Uninstallation of the USB driver If the controller is connected, the uninstallation of the driver might fail.

SFOD-OMT0009) 3.2 (1) LED ON PWR : OFF RUN : USB USB : USB ALM : LED PWR PWR (2) /SMC/JXC Controller PC 6 No.SFOD-OMT0011CN-A (Y) (N) OK PC a) b) USB c) USB 7 No.SFOD-OMT0011CN-A PC communication status Offline (Online) (3) Alarm 4.8(3) 8 No.SFOD-OMT0011CN-A 4. 4.1 (1) ON/OFF (1-1)(1-8) (1-1) (1-5) (1-4) (1-3) ON/OFF (1-2) (1-6) (1-7) No. (1-8) (1-

0.31Nm) 2 Assy () 28 - No.ZQ-OM01401-B 8.2. 1) 2 3) 0.12~0.18Nm) 8.3 1)2 2)2 : 0.054~0.080Nm 2 29 - No.ZQ-OM01401-B 8.4 1)(V)2 2) 2 : 0.11~0.13Nm 3)(V) 2 8.5 1)8.4 Ass'y Ass'y (V) 2)Ass'y 3)8.4 Ass'y 30 - No.ZQ-OM01401-B 8.6 1 2 32 4 5kPa ( ) 5 6) 7 31 - No.ZQ-OM01401-B 9. 9.1 ZQA [] 5 to 50 () 2] 1) 20 [m/s 2] 2) 100 [m/s CE / UKCA (EMC RoHS ) 1) 10~150Hz X,Y,

Accessory set VBAT5A-Y-3 Hex. socket head plug For Drain port 1 pc. AIR TANK Safety valve Pressure gauge Piping components for tank connection 1 pc. 1 pc. 1 pc.

VBA-0M-P018-A VBAT10A1-U-X104 VBAT-M35C 2 / VBAT05A1-U-X104 VBA1 4 / VBA1 4 /VBAT10A-Y-3 VBA2 4 VBAT05A1-U-X104 VBAT10A1-U-X104 VBA1 1 O /VBAT5A-Y-3 O VBA1 1 VBA2 1 1 1 / VBAT-U 1 1 1 / VBAT-U 1 1 1 / VBAT-M35 / VBAT-M35C () () 1 1 / VBAT-M35 / VBAT-M35C () () 1 1 1 1 SMC ( 3 ) VBA2 VBA1 () 30 IN 1.5MPa VBA1A 2MPa, O 1.5MPa OUT VBATA1--X104 VBAT-V1 OUT

VBA-0M-S006 1.5MPa VBA1A 2MPa, 1.5MPa 1 1 1 VBA1 1 O VBA2 4 VBA2 1 VBA1 4 1 1 1 1 () () / OUT / VBAT-M46C / VBAT-M46 4 11 () VBAT10S1-U-X104 / /VBAT10S-Y-4 () VBAT-U 30 1 1 VBA1 4 O VBA1 1 /VBAT5S-Y-4 1 1 / 1 VBAT-U 1 1 ( 3 ) VBAT-V1 () () / / VBAT-M46C / VBAT-M46 VBAT05S1-U-X104 2 OUT VBAT-M46C VBAT05S1-U-X104 VBAT10S1-U-X104 IN VBAT05S1-U-X104

How to Use DIN Terminal Type Y DIN connector type Y is a DIN connector that confirms to the DIN pitch 8-mm standard. D type DIN connector with 9.4 mm pitch between terminals is not interchangeable. Connection 1. Loosen the holding screw and pull the connector out of the Caution solenoid valve terminal block.

VP4*50, VP4*70, VVP4*0 Series 5 1 ()ISO VG32 2 ()ISO VG32 1 Rc Nm Rc 1/8 35 Rc 1/4 812 Rc 3/8 1520 Rc 1/2 2025 Rc 3/4 2830 Rc 1 3638 Rc 1 1/4 4042 Rc 1 1/2 4850 P P A,B () 5 +/30N 6 VP450-OMU0001 VP4*50, VP4*70, VVP4*0 Series 5 1 ()ISO VG32 2 ()ISO VG32 EAEB 3 30 ( ) , 7 VP450-OMU0001 VP4*50, VP4*70, VVP4*0 Series a)3f 3d (P ) 3 (P ) 2-3.5 b)O 1.25mm 10 (VVP460 8 ) 2-4 Y

) 3f 0.5Nm15% a) 3f 3d b) O 1.25mm2-3.5 Y 1.25 mm2-4 c) 6~12mm 9~12mm 1) 4 () 2) () M4 0.60.06Nm N.C.

ACl00V AC200V DC + DIN 7 VT317**-OMH0003-A DIN 1. 1) () 2) 3) 3a 4) 2. 1) 2 33f 3e Y 3f )0.5Nm15% a 3f 3d 2 3.5 b O 1.25mm 2 4 Y 1.25mm c 612mm 912 3. 1) ) 2) 3) )0.5Nm20% 904 DIN AC DC DC AC 8 VT317**-OMH0003-A N.C.N.O. 1. N.C./N.O.180 N.C. N.O. N.C.N.O. * N.C.N.O. N.C. N.O. N.C. N.O. 1.M4 2 1.4Nm 2.

DCDIN No.1 +No.2 1) () 2) 3) , 4) DIN DIN DIN DIN DIN GDM2B 2. 2. 2. 2. 1) 2) 3) Y )0.5Nm15% a b O 1.25 3.5 Y 1.25 4 c 612mm 912mm 1. 2. 3. 3. 3. 3. 3. 1 ) 2) 3) )0.5Nm20% AC100V AC200V DC + DC DC 7 VT315**-OMH0005-A V V V VT315 Series/ T315 Series/ T315 Series/ T315 Series/ 1. 1. 1. 1. 1 1 1 230 1 18VA50Hz 16 P R 2PR 3/8 AC AC100V110V200V220V50/60Hz O P8 4 DC DC12V24V48V100

Red ST(M) LED is flashing Red PWR(V) LED is On Red ST(M) LED is On Green MS LED is On Red PWR LED is On Green LEDs are On Red MS LED is On LED display LED display Off Off URL http://www.smcworld.com PWR(V) Display ST(M) PWR MS NS Displays the network status. for 2 hours each in direction X, Y and Z respectively (De-energized) Displays the module status.

SF for 2 hours each in direction X, Y and Z respectively (De-energized) Displays system fault. Displays the status of the power supply voltage for outputs. Displays the status of the power supply voltage for control and inputs. Displays the diagnosis status of the unit. Connection error between units occurred. A unit other than the SI unit has been diagnosed and detected.